Optivolt Labs Inc OPT10M440W — CEC Solar Module Specifications

Manufacturer: Optivolt Labs Inc Registry: CEC Verified Engineering Specification

Optivolt Labs Inc OPT10M440W is a 440.0 W STC (404.3 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 22.68% efficiency, 39.62 V Voc at 25 C, and 43.5 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
404.3 W
Voc @ 25C
39.62 V
Efficiency
22.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Optivolt Labs Inc OPT10M440W Compare Against Peer CEC Listings?

Engineering position of Optivolt Labs Inc OPT10M440W (440.0 W STC) vs. AEG SOLAR ENERGY SRL ALPS54D30-440/TP across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, Optivolt Labs Inc OPT10M440W pairs strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677) with 39.62 V nominal Voc. An 8 kW residential build (8,360 W DC, 7,682 W PTC) saves ~$2,092/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AEG SOLAR ENERGY SRL ALPS54D30-440/TP offers a 440.0 W alternative.

Where Does Optivolt Labs Inc OPT10M440W Fall Across Listed CEC Models?

Plots Optivolt Labs Inc OPT10M440W at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Optivolt Labs Inc OPT10M440W (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCOptivolt Labs Inc : 440.0 W

What Dataset Percentiles Define Optivolt Labs Inc OPT10M440W?

Benchmarks Optivolt Labs Inc OPT10M440W on STC wattage, thermal PTC/STC retention, and 22.68 aperture conversion efficiency against CEC peers.

Optivolt Labs Inc OPT10M440W Engineering BenchmarksPercentile comparison of Optivolt Labs Inc OPT10M440W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention91.9%Module Efficiency22.68%

What Do the Dataset Ranks Show for Optivolt Labs Inc OPT10M440W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Optivolt Labs Inc OPT10M440W by Optivolt Labs Inc.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,656

22.68% Aperture Efficiency

Power density 226.8 W/m2 (2.77 percentage points above 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.5 V at -10 C (565.5 V string) and 44.61 V at -20 C (13 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 36.9 m2 (397 sq ft) producing 7,682 W PTC; NEC 690.8 OCPD floor is 21.7 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.62 * (1 + (-0.28/100) * (-10 - 25)) = 43.5 V | OCPD = 1.56 * 13.91 = 21.7 A

Inputs from CEC Modules.csv for Optivolt Labs Inc OPT10M440W: Voc=39.62 V, beta_Voc=-0.28%/C, Isc=13.91 A, STC=440.0 W, Area=1.94 m2.

Result: 13 panels max on 600 V (565.5 V); 19 panels for 8 kW (397 sq ft).

What Are the Published CEC Specifications for Optivolt Labs Inc OPT10M440W?

Laboratory test ratings recorded for Optivolt Labs Inc OPT10M440W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Optivolt Labs Inc OPT10M440W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 404.3 W (91.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.62 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.91 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.38 V / 13.19 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.28 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.68% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Optivolt Labs Inc OPT10M440W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (397 sq ft at 8 kW), and estimated Year-1 electric bill offset for Optivolt Labs Inc OPT10M440W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 292 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 397 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 480 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Optivolt Labs Inc Series?

Sibling wattage bins and frame colors grouped with Optivolt Labs Inc OPT10M440W under Optivolt Labs Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Optivolt Labs Inc OPT10M440W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Optivolt Labs Inc OPT10M435W 435.0 W 405.9 W 38.7 V 33.4 V 22.42%
Optivolt Labs Inc OPT10M440W 440.0 W 404.3 W 39.62 V 33.38 V 22.68%
Optivolt Labs Inc OPT10M445W 445.0 W 409.1 W 39.69 V 33.44 V 22.94%

How Many Optivolt Labs Inc OPT10M440W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Optivolt Labs Inc OPT10M440W (beta_Voc -0.28%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=39.62V and beta_Voc=-0.28%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.61 V 13 panels 579.9 V 22 panels
-10 C (14 F) 43.5 V 13 panels 565.5 V 22 panels
0 C (32 F) 42.39 V 14 panels 593.5 V 23 panels
25 C (77 F STC) 39.62 V 15 panels 594.3 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Optivolt Labs Inc OPT10M440W?

Closest cross-brand CEC competitors to Optivolt Labs Inc OPT10M440W matched near 440.0 W STC and 39.62 V Voc, led by AEG SOLAR ENERGY SRL ALPS54D30-440/TP.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AEG SOLAR ENERGY SRL ALPS54D30-440/TP
AEG SOLAR ENERGY SRL
440.0 W Tie (0 W) 39.5 V 22.11% 94.3%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW440M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
440.0 W Tie (0 W) 39.79 V 23.16% 94.7%
Aptos Solar Technology LLC DNA-108-MFN10-440W
Aptos Solar Technology LLC
440.0 W Tie (0 W) 39.0 V 22.68% 95.1%
Bluesun Solar CoLtd BSM440M10-54HNH
Bluesun Solar CoLtd
440.0 W Tie (0 W) 38.9 V 22.68% 95.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Optivolt Labs Inc OPT10M440W?

Evaluate Optivolt Labs Inc OPT10M440W (440.0 W STC, 39.62 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Optivolt Labs Inc OPT10M440W reaches 44.61 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 397 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (397 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Optivolt Labs Inc OPT10M440W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Optivolt Labs Inc OPT10M440W 8 kW Residential Fit

Needs 19 modules (397 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AEG SOLAR ENERGY SRL ALPS54D30-440/TP.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 404.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Optivolt Labs Inc OPT10M440W by Optivolt Labs Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Optivolt Labs Inc OPT10M440W?

Multiplying Optivolt Labs Inc OPT10M440W's 13.91 A short-circuit current by 1.56 equals 21.7 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Optivolt Labs Inc OPT10M440W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.5 V cold Voc at 14 F and handles 13.91 A Isc; string inverters cap Optivolt Labs Inc OPT10M440W at 13 panels on 600 V.

Is Optivolt Labs Inc OPT10M440W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Optivolt Labs Inc OPT10M440W rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.