Skip to main content
WireAndSun
Calculators
CEC PV Module

Mundra Solar Energy Limited (Adani) ASB-M10-144-540 — CEC Solar Module Specifications

Manufacturer: Mundra Solar Energy Limited (Adani) Registry: CEC Verified Engineering Specification

Mundra Solar Energy Limited (Adani) ASB-M10-144-540 is a 540.0 W STC (500.4 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.01% efficiency, 49.32 V Voc at 25 C, and 54.24 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
500.4 W
Voc @ 25C
49.32 V
Efficiency
21.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mundra Solar Energy Limited (Adani) ASB-M10-144-540 Compare Against Peer CEC Listings?

How Mundra Solar Energy Limited (Adani) Mundra Solar Energy Limited (Adani) ASB-M10-144-540 handles rooftop heat (500.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Mundra Solar Energy Limited (Adani) ASB-M10-144-540 exhibits 13.71 A short-circuit current, requiring a 21.39 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,265 of 21,677 (130.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.5 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.32 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Mundra Solar Energy Limited (Adani) ASB-M10-144-540 Fall Across Listed CEC Models?

Where Mundra Solar Energy Limited (Adani) ASB-M10-144-540 (540.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mundra Solar Energy Limited (Adani) ASB-M10-144-540 (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMundra Solar Energ: 540.0 W

What Dataset Percentiles Define Mundra Solar Energy Limited (Adani) ASB-M10-144-540?

Percentile placement of Mundra Solar Energy Limited (Adani) ASB-M10-144-540 across power density (210.1 W/m2), thermal retention, and nameplate STC wattage.

Mundra Solar Energy Limited (Adani) ASB-M10-144-540 Engineering BenchmarksPercentile comparison of Mundra Solar Energy Limited (Adani) ASB-M10-144-540 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention92.7%Module Efficiency21.01%

What Do the Dataset Ranks Show for Mundra Solar Energy Limited (Adani) ASB-M10-144-540?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mundra Solar Energy Limited (Adani) ASB-M10-144-540 specifications.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,421

21.01% Aperture Efficiency

Power density 210.1 W/m2 (1.10 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.24 V at -10 C (596.6 V string) and 55.65 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,506 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.32 * (1 + (-0.285/100) * (-10 - 25)) = 54.24 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for Mundra Solar Energy Limited (Adani) ASB-M10-144-540: Voc=49.32 V, beta_Voc=-0.285%/C, Isc=13.71 A, STC=540.0 W, Area=2.57 m2.

Result: 11 panels max on 600 V (596.6 V); 15 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for Mundra Solar Energy Limited (Adani) ASB-M10-144-540?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mundra Solar Energy Limited (Adani) ASB-M10-144-540.

Official California Energy Commission (NREL SAM) test parameters for Mundra Solar Energy Limited (Adani) ASB-M10-144-540.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 500.4 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.8 V / 12.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.285 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.01% (2.57 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Mundra Solar Energy Limited (Adani) ASB-M10-144-540 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mundra Solar Energy Limited (Adani) ASB-M10-144-540 (540.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 332 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 415 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 526 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Mundra Solar Energy Limited (Adani) Series?

All closely matched Mundra Solar Energy Limited (Adani) wattages and cosmetic trims sharing the Mundra Solar Energy Limited (Adani) ASB-M10-144-540 architecture.

Sibling CEC listings grouped into the Mundra Solar Energy Limited (Adani) ASB-M10-144-540 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mundra Solar Energy Limited (Adani) ASB-M10-144-530 530.0 W 490.8 W 48.95 V 41.49 V 20.62%
Mundra Solar Energy Limited (Adani) ASB-M10-144-535 535.0 W 495.6 W 49.12 V 41.64 V 20.82%
Mundra Solar Energy Limited (Adani) ASB-M10-144-540 540.0 W 500.4 W 49.32 V 41.8 V 21.01%
Mundra Solar Energy Limited (Adani) ASB-M10-144-545 545.0 W 505.1 W 49.48 V 41.94 V 21.21%

How Many Mundra Solar Energy Limited (Adani) ASB-M10-144-540 Modules Fit in a Cold-Weather String?

Maximum series module counts for Mundra Solar Energy Limited (Adani) ASB-M10-144-540 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.32V and beta_Voc=-0.285%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.65 V 10 panels 556.5 V 17 panels
-10 C (14 F) 54.24 V 11 panels 596.6 V 18 panels
0 C (32 F) 52.83 V 11 panels 581.1 V 18 panels
25 C (77 F STC) 49.32 V 12 panels 591.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Mundra Solar Energy Limited (Adani) ASB-M10-144-540?

Alternative CEC solar modules from competing brands near Mundra Solar Energy Limited (Adani) ASB-M10-144-540 (540.0 W), including GCL System Integration Technology Co Ltd GCL-M10/72GDF540.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M10/72GDF540
GCL System Integration Technology Co Ltd
540.0 W Tie (0 W) 49.24 V 21.09% 93.5%
Aptos Solar Technology LLC DNA-144-BF10-540W
Aptos Solar Technology LLC
540.0 W Tie (0 W) 49.5 V 20.93% 94.2%
Elin Energy (Sirius PV) ELNSM72M-HC-BF-540
Elin Energy (Sirius PV)
540.0 W Tie (0 W) 49.5 V 21.09% 94.4%
EMMVEE Photovoltaic Power Private Limited E540HCBG144
EMMVEE Photovoltaic Power Private Limited
540.0 W Tie (0 W) 49.5 V 21.09% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mundra Solar Energy Limited (Adani) ASB-M10-144-540?

Evaluate Mundra Solar Energy Limited (Adani) ASB-M10-144-540 (540.0 W STC, 49.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mundra Solar Energy Limited (Adani) ASB-M10-144-540 reaches 55.65 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 415 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Mundra Solar Energy Limited (Adani) ASB-M10-144-540 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mundra Solar Energy Limited (Adani) ASB-M10-144-540 8 kW Residential Fit

Needs 15 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M10/72GDF540.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 500.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mundra Solar Energy Limited (Adani) ASB-M10-144-540 by Mundra Solar Energy Limited (Adani) grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Mundra Solar Energy Limited (Adani) ASB-M10-144-540 PTC wattage (500.4 W) lower than STC (540.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 500.4 W PTC (92.7% retention) across Mundra Solar Energy Limited (Adani) ASB-M10-144-540's 2.57 m2 aperture.

Who should skip Mundra Solar Energy Limited (Adani) ASB-M10-144-540 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Mundra Solar Energy Limited (Adani) ASB-M10-144-540 panels (415 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M10/72GDF540.

What is the 1,000 V commercial string limit for Mundra Solar Energy Limited (Adani) ASB-M10-144-540?

On 1,000 V commercial inverters at -10 C (54.24 V cold Voc), Mundra Solar Energy Limited (Adani) ASB-M10-144-540 fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.