Skip to main content
WireAndSun
Calculators
CEC PV Module

Maxeon Solar Technologies Ltd SPR-X21-470-COM — CEC Solar Module Specifications

Manufacturer: Maxeon Solar Technologies Ltd Registry: CEC Verified Engineering Specification

Maxeon Solar Technologies Ltd SPR-X21-470-COM is a 470.0 W STC (438.0 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 21.76% efficiency, 91.5 V Voc at 25 C, and 100.88 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
470.0 W
PTC Wattage
438.0 W
Voc @ 25C
91.5 V
Efficiency
21.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Maxeon Solar Technologies Ltd SPR-X21-470-COM Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Maxeon Solar Technologies Ltd SPR-X21-470-COM (Mono-c-Si) residential solar systems.

Maxeon Solar Technologies Ltd SPR-X21-470-COM delivers 217.6 W/m2 (1.85 percentage points above 19.91% CEC median) and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 103.56 V per unit, capping 600 V circuits at 5 panels. Compare specs directly with Heliene 96M475 (475.0 W).

Where Does Maxeon Solar Technologies Ltd SPR-X21-470-COM Fall Across Listed CEC Models?

Comparison of Maxeon Solar Technologies Ltd SPR-X21-470-COM (470.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Maxeon Solar Technologies Ltd SPR-X21-470-COM (470.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMaxeon Solar Techn: 470.0 W

What Dataset Percentiles Define Maxeon Solar Technologies Ltd SPR-X21-470-COM?

Relative ranking of Maxeon Solar Technologies Ltd SPR-X21-470-COM across nameplate watts, 93.2% PTC thermal ratio, and module aperture efficiency.

Maxeon Solar Technologies Ltd SPR-X21-470-COM Engineering BenchmarksPercentile comparison of Maxeon Solar Technologies Ltd SPR-X21-470-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage470.0 WPTC/STC Retention93.2%Module Efficiency21.76%

What Do the Dataset Ranks Show for Maxeon Solar Technologies Ltd SPR-X21-470-COM?

Summary of Maxeon Solar Technologies Ltd SPR-X21-470-COM output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #4,967 / 21,677

Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,690

21.76% Aperture Efficiency

Power density 217.6 W/m2 (1.85 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 100.88 V at -10 C (504.4 V string) and 103.56 V at -20 C (5 max).

8 kW Reference Array

18 Panels = 8,460 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,884 W PTC; NEC 690.8 OCPD floor is 10.06 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 91.5 * (1 + (-0.293/100) * (-10 - 25)) = 100.88 V | OCPD = 1.56 * 6.45 = 10.06 A

Inputs from CEC Modules.csv for Maxeon Solar Technologies Ltd SPR-X21-470-COM: Voc=91.5 V, beta_Voc=-0.293%/C, Isc=6.45 A, STC=470.0 W, Area=2.16 m2.

Result: 5 panels max on 600 V (504.4 V); 18 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for Maxeon Solar Technologies Ltd SPR-X21-470-COM?

Complete CEC test sheet for Maxeon Solar Technologies Ltd SPR-X21-470-COM including Isc (6.45 A), Voc (91.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Maxeon Solar Technologies Ltd SPR-X21-470-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 470.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 438.0 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 91.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 77.6 V / 6.06 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.293 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.76% (2.16 m2) Array roof footprint density
Cell Count & Technology 128 cells (Mono-c-Si) Monofacial backsheet

How Many Maxeon Solar Technologies Ltd SPR-X21-470-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Maxeon Solar Technologies Ltd SPR-X21-470-COM.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.11 kW 302 sq ft $1,529 $2,586
8 kW Class 18 8.46 kW 419 sq ft $2,117 $3,580
10 kW Class 22 10.34 kW 512 sq ft $2,588 $4,376

How Many Maxeon Solar Technologies Ltd SPR-X21-470-COM Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Maxeon Solar Technologies Ltd SPR-X21-470-COM (91.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=91.5V and beta_Voc=-0.293%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 103.56 V 5 panels 517.8 V 9 panels
-10 C (14 F) 100.88 V 5 panels 504.4 V 9 panels
0 C (32 F) 98.2 V 6 panels 589.2 V 10 panels
25 C (77 F STC) 91.5 V 6 panels 549.0 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to Maxeon Solar Technologies Ltd SPR-X21-470-COM?

Four comparable CEC modules such as Heliene 96M475 (475.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M475
Heliene
475.0 W +5.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -10.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-470MS
CSI Solar Co Ltd
470.0 W Tie (0 W) 52.5 V 20.52% 93.5%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W +10.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Maxeon Solar Technologies Ltd SPR-X21-470-COM?

Evaluate Maxeon Solar Technologies Ltd SPR-X21-470-COM (470.0 W STC, 91.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Maxeon Solar Technologies Ltd SPR-X21-470-COM reaches 103.56 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Maxeon Solar Technologies Ltd SPR-X21-470-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Maxeon Solar Technologies Ltd SPR-X21-470-COM 8 kW Residential Fit

Needs 18 modules (419 sq ft) with a 15 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Heliene 96M475.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Maxeon Solar Technologies Ltd SPR-X21-470-COM by Maxeon Solar Technologies Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Maxeon Solar Technologies Ltd SPR-X21-470-COM panels fit on a 600 V winter solar string?

At -10 C (14 F), Maxeon Solar Technologies Ltd SPR-X21-470-COM cold Voc rises from 91.5 V to 100.88 V (beta_Voc -0.293%/C), capping a 600 V string at 5 panels (504.4 V).

How much roof area does an 8 kW array of Maxeon Solar Technologies Ltd SPR-X21-470-COM need?

An 8 kW DC system uses 18 Maxeon Solar Technologies Ltd SPR-X21-470-COM modules (8,460 W STC / 7,884 W PTC), covering roughly 419 sq ft and saving ~$2,117/yr at 18.54 c/kWh.

How does Maxeon Solar Technologies Ltd SPR-X21-470-COM compare against Heliene 96M475?

Maxeon Solar Technologies Ltd SPR-X21-470-COM outputs 470.0 W STC (91.5 V Voc, rank #4,967 of 21,677), while Heliene 96M475 delivers 475.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.