Manufacturer: Maxeon Solar Technologies Ltd Registry: CEC Verified Engineering Specification

Maxeon Solar Technologies Ltd SPR-MAX3-390-COM is a 390.0 W STC (362.8 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 22.03% efficiency, 75.3 V Voc at 25 C, and 81.31 V cold Voc at -10 C (7 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
362.8 W
Voc @ 25C
75.3 V
Efficiency
22.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Maxeon Solar Technologies Ltd SPR-MAX3-390-COM Compare Against Peer CEC Listings?

How Maxeon Solar Technologies Ltd Maxeon Solar Technologies Ltd SPR-MAX3-390-COM handles rooftop heat (362.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Maxeon Solar Technologies Ltd SPR-MAX3-390-COM exhibits 6.55 A short-circuit current, requiring a 10.22 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #10,321 of 21,677 (20.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 37.2 m2 for an 8 kW system (26 panels for 10 kW). Higher 75.3 V open-circuit voltage caps 600 V residential strings at 7 panels at 14 F (-10 C).

Where Does Maxeon Solar Technologies Ltd SPR-MAX3-390-COM Fall Across Listed CEC Models?

Where Maxeon Solar Technologies Ltd SPR-MAX3-390-COM (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Maxeon Solar Technologies Ltd SPR-MAX3-390-COM (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMaxeon Solar Techn: 390.0 W

What Dataset Percentiles Define Maxeon Solar Technologies Ltd SPR-MAX3-390-COM?

Percentile placement of Maxeon Solar Technologies Ltd SPR-MAX3-390-COM across power density (220.3 W/m2), thermal retention, and nameplate STC wattage.

Maxeon Solar Technologies Ltd SPR-MAX3-390-COM Engineering BenchmarksPercentile comparison of Maxeon Solar Technologies Ltd SPR-MAX3-390-COM wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention93.0%Module Efficiency22.03%

What Do the Dataset Ranks Show for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM?

Four critical engineering numbers homeowners and solar installers check first when reviewing Maxeon Solar Technologies Ltd SPR-MAX3-390-COM specifications.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,050

22.03% Aperture Efficiency

Power density 220.3 W/m2 (2.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

7 Panels Max @ -10 C (600 V)

Cold Voc reaches 81.31 V at -10 C (569.2 V string) and 83.03 V at -20 C (7 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 37.2 m2 (400 sq ft) producing 7,619 W PTC; NEC 690.8 OCPD floor is 10.22 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 75.3 * (1 + (-0.228/100) * (-10 - 25)) = 81.31 V | OCPD = 1.56 * 6.55 = 10.22 A

Inputs from CEC Modules.csv for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM: Voc=75.3 V, beta_Voc=-0.228%/C, Isc=6.55 A, STC=390.0 W, Area=1.77 m2.

Result: 7 panels max on 600 V (569.2 V); 21 panels for 8 kW (400 sq ft).

What Are the Published CEC Specifications for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM.

Official California Energy Commission (NREL SAM) test parameters for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 362.8 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 75.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 6.55 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 64.5 V / 6.05 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.228 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.03% (1.77 m2) Array roof footprint density
Cell Count & Technology 104 cells (Mono-c-Si) Monofacial backsheet

How Many Maxeon Solar Technologies Ltd SPR-MAX3-390-COM Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Maxeon Solar Technologies Ltd SPR-MAX3-390-COM (390.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 305 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 400 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 495 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Maxeon Solar Technologies Ltd Series?

All closely matched Maxeon Solar Technologies Ltd wattages and cosmetic trims sharing the Maxeon Solar Technologies Ltd SPR-MAX3-390-COM architecture.

Sibling CEC listings grouped into the Maxeon Solar Technologies Ltd SPR-MAX3-390-COM wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Maxeon Solar Technologies Ltd SPR-MAX3-380-COM 380.0 W 353.3 W 75.2 V 63.1 V 21.47%
Maxeon Solar Technologies Ltd SPR-MAX3-390-COM 390.0 W 362.8 W 75.3 V 64.5 V 22.03%

How Many Maxeon Solar Technologies Ltd SPR-MAX3-390-COM Modules Fit in a Cold-Weather String?

Maximum series module counts for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=75.3V and beta_Voc=-0.228%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 83.03 V 7 panels 581.2 V 12 panels
-10 C (14 F) 81.31 V 7 panels 569.2 V 12 panels
0 C (32 F) 79.59 V 7 panels 557.1 V 12 panels
25 C (77 F STC) 75.3 V 7 panels 527.1 V 13 panels

Which Cross-Brand Solar Modules Compare Closest to Maxeon Solar Technologies Ltd SPR-MAX3-390-COM?

Alternative CEC solar modules from competing brands near Maxeon Solar Technologies Ltd SPR-MAX3-390-COM (390.0 W), including CSI Solar Co Ltd CS1Y-390MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-390MS
CSI Solar Co Ltd
390.0 W Tie (0 W) 51.9 V 20.0% 94.0%
BYD Company Limited BYD415MIK-36
BYD Company Limited
395.0 W +5.0 W 50.06 V 19.65% 93.9%
ELITE Solar ET-M672BH395GL
ELITE Solar
395.0 W +5.0 W 49.6 V 19.36% 93.2%
ELITE Solar ET-M672BH395WW
ELITE Solar
395.0 W +5.0 W 49.5 V 19.85% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM?

Evaluate Maxeon Solar Technologies Ltd SPR-MAX3-390-COM (390.0 W STC, 75.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Maxeon Solar Technologies Ltd SPR-MAX3-390-COM reaches 83.03 V per panel—exceeding 7 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 400 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (400 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Maxeon Solar Technologies Ltd SPR-MAX3-390-COM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Maxeon Solar Technologies Ltd SPR-MAX3-390-COM 8 kW Residential Fit

Needs 21 modules (400 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 7 panels (-10 C) or 7 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-390MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 362.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM by Maxeon Solar Technologies Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Maxeon Solar Technologies Ltd SPR-MAX3-390-COM PTC wattage (362.8 W) lower than STC (390.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 362.8 W PTC (93.0% retention) across Maxeon Solar Technologies Ltd SPR-MAX3-390-COM's 1.77 m2 aperture.

Who should skip Maxeon Solar Technologies Ltd SPR-MAX3-390-COM on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Maxeon Solar Technologies Ltd SPR-MAX3-390-COM panels (400 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS1Y-390MS.

What is the 1,000 V commercial string limit for Maxeon Solar Technologies Ltd SPR-MAX3-390-COM?

On 1,000 V commercial inverters at -10 C (81.31 V cold Voc), Maxeon Solar Technologies Ltd SPR-MAX3-390-COM fits up to 12 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.