Luxor Solar LX-330M/156-72+ is a 330.0 W STC (296.0 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.1 V Voc at 25 C, and 51.99 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 296.0 W
- Voc @ 25C
- 46.1 V
- Efficiency
- 17.01%
How Does Luxor Solar LX-330M/156-72+ Compare Against Peer CEC Listings?
Engineering position of Luxor Solar LX-330M/156-72+ (330.0 W STC) vs. Centrosolar America TM7 330SW across 5,889 CEC Mono-c-Si solar modules.
Ranking #14,165 across 21,677 CEC solar panels (below all-CEC median; higher than 32.9% of peers), Luxor Solar LX-330M/156-72+ operates as a compact residential or specialty off-grid module sitting 80.0 W below the 410.0 W Mono-c-Si median. Mid-range 46.1 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 89.7% PTC-to-STC thermal output (296.0 W real-world rating), 25 panels occupy 522 sq ft and offset roughly $2,065/yr at average US rates (or $3,492/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Luxor Solar LX-330M/156-72+ Fall Across Listed CEC Models?
Plots Luxor Solar LX-330M/156-72+ at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Luxor Solar LX-330M/156-72+?
Benchmarks Luxor Solar LX-330M/156-72+ on STC wattage, thermal PTC/STC retention, and 17.01 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Luxor Solar LX-330M/156-72+?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Luxor Solar LX-330M/156-72+ by Luxor Solar.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.01% Aperture Efficiency
Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.99 V at -10 C (571.9 V string) and 53.67 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.5 m2 (522 sq ft) producing 7,400 W PTC; NEC 690.8 OCPD floor is 14.34 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.1 * (1 + (-0.365/100) * (-10 - 25)) = 51.99 V | OCPD = 1.56 * 9.19 = 14.34 A
Inputs from CEC Modules.csv for Luxor Solar LX-330M/156-72+: Voc=46.1 V, beta_Voc=-0.365%/C, Isc=9.19 A, STC=330.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (571.9 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for Luxor Solar LX-330M/156-72+?
Laboratory test ratings recorded for Luxor Solar LX-330M/156-72+ (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 296.0 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.3 V / 8.85 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.365 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.01% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Luxor Solar LX-330M/156-72+ Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for Luxor Solar LX-330M/156-72+.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 397 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Luxor Solar Series?
Sibling wattage bins and frame colors grouped with Luxor Solar LX-330M/156-72+ under Luxor Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Luxor Solar LX-325M/156-72+ | 325.0 W | 291.3 W | 46.0 V | 37.1 V | 16.75% |
| Luxor Solar LX-330M/156-72+ | 330.0 W | 296.0 W | 46.1 V | 37.3 V | 17.01% |
| Luxor Solar LX-335M/156-72+ | 335.0 W | 300.6 W | 46.15 V | 37.4 V | 17.26% |
How Many Luxor Solar LX-330M/156-72+ Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Luxor Solar LX-330M/156-72+ (beta_Voc -0.365%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.67 V | 11 panels | 590.4 V | 18 panels |
| -10 C (14 F) | 51.99 V | 11 panels | 571.9 V | 19 panels |
| 0 C (32 F) | 50.31 V | 11 panels | 553.4 V | 19 panels |
| 25 C (77 F STC) | 46.1 V | 13 panels | 599.3 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Luxor Solar LX-330M/156-72+?
Closest cross-brand CEC competitors to Luxor Solar LX-330M/156-72+ matched near 330.0 W STC and 46.1 V Voc, led by Centrosolar America TM7 330SW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TM7 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| Centrosolar America TM7S 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| Advance Power API-P330 Advance Power |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| Auxin Solar AXN6P612T330 Auxin Solar |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
What Are the Design Limits and Best-Fit Uses for Luxor Solar LX-330M/156-72+?
Evaluate Luxor Solar LX-330M/156-72+ (330.0 W STC, 46.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Luxor Solar LX-330M/156-72+ reaches 53.67 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of Luxor Solar LX-330M/156-72+ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Luxor Solar LX-330M/156-72+ 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America TM7 330SW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 296.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Luxor Solar LX-330M/156-72+ by Luxor Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Luxor Solar LX-330M/156-72+ panels fit on a 600 V winter solar string?
At -10 C (14 F), Luxor Solar LX-330M/156-72+ cold Voc rises from 46.1 V to 51.99 V (beta_Voc -0.365%/C), capping a 600 V string at 11 panels (571.9 V).
How much roof area does an 8 kW array of Luxor Solar LX-330M/156-72+ need?
An 8 kW DC system uses 25 Luxor Solar LX-330M/156-72+ modules (8,250 W STC / 7,400 W PTC), covering roughly 522 sq ft and saving ~$2,065/yr at 18.54 c/kWh.
How does Luxor Solar LX-330M/156-72+ compare against Centrosolar America TM7 330SW?
Luxor Solar LX-330M/156-72+ outputs 330.0 W STC (46.1 V Voc, rank #14,165 of 21,677), while Centrosolar America TM7 330SW delivers 330.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)