Skip to main content
WireAndSun
Calculators
CEC PV Module

LG Electronics Inc LG380N1K-E6 — CEC Solar Module Specifications

Manufacturer: LG Electronics Inc Registry: CEC Verified Engineering Specification

LG Electronics Inc LG380N1K-E6 is a 380.0 W STC (353.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 21.23% efficiency, 41.7 V Voc at 25 C, and 45.47 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
353.6 W
Voc @ 25C
41.7 V
Efficiency
21.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LG Electronics Inc LG380N1K-E6 Compare Against Peer CEC Listings?

Solar engineering breakdown for LG Electronics Inc LG380N1K-E6: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from LG Electronics Inc and peers, LG Electronics Inc LG380N1K-E6 stands 30.0 W below the 410.0 W Mono-c-Si median and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Mid-range 41.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does LG Electronics Inc LG380N1K-E6 Fall Across Listed CEC Models?

Distribution marker showing LG Electronics Inc LG380N1K-E6 (380.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LG Electronics Inc LG380N1K-E6 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLG Electronics Inc: 380.0 W

What Dataset Percentiles Define LG Electronics Inc LG380N1K-E6?

Dataset percentiles tracking LG Electronics Inc LG380N1K-E6 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

LG Electronics Inc LG380N1K-E6 Engineering BenchmarksPercentile comparison of LG Electronics Inc LG380N1K-E6 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention93.1%Module Efficiency21.23%

What Do the Dataset Ranks Show for LG Electronics Inc LG380N1K-E6?

Benchmark highlights for LG Electronics Inc LG380N1K-E6 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,486

21.23% Aperture Efficiency

Power density 212.3 W/m2 (1.32 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.47 V at -10 C (591.1 V string) and 46.54 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 39.4 m2 (424 sq ft) producing 7,779 W PTC; NEC 690.8 OCPD floor is 17.83 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.7 * (1 + (-0.258/100) * (-10 - 25)) = 45.47 V | OCPD = 1.56 * 11.43 = 17.83 A

Inputs from CEC Modules.csv for LG Electronics Inc LG380N1K-E6: Voc=41.7 V, beta_Voc=-0.258%/C, Isc=11.43 A, STC=380.0 W, Area=1.79 m2.

Result: 13 panels max on 600 V (591.1 V); 22 panels for 8 kW (424 sq ft).

What Are the Published CEC Specifications for LG Electronics Inc LG380N1K-E6?

Official CEC datasheet figures for LG Electronics Inc LG380N1K-E6 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for LG Electronics Inc LG380N1K-E6.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 353.6 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.2 V / 10.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.258 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.23% (1.79 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many LG Electronics Inc LG380N1K-E6 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many LG Electronics Inc LG380N1K-E6 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 308 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 424 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 520 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This LG Electronics Inc Series?

Consolidated LG Electronics Inc wattage variants sharing the LG Electronics Inc LG380N1K-E6 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the LG Electronics Inc LG380N1K-E6 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LG Electronics Inc LG375N1K-E6 375.0 W 348.8 W 41.5 V 34.9 V 20.95%
LG Electronics Inc LG380N1K-E6 380.0 W 353.6 W 41.7 V 35.2 V 21.23%
LG Electronics Inc LG390N1K-E6 390.0 W 363.2 W 42.1 V 35.5 V 21.79%

How Many LG Electronics Inc LG380N1K-E6 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on LG Electronics Inc LG380N1K-E6 (45.47 V at 14 F).

Computed from Voc=41.7V and beta_Voc=-0.258%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.54 V 12 panels 558.5 V 21 panels
-10 C (14 F) 45.47 V 13 panels 591.1 V 21 panels
0 C (32 F) 44.39 V 13 panels 577.1 V 22 panels
25 C (77 F STC) 41.7 V 14 panels 583.8 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to LG Electronics Inc LG380N1K-E6?

Competing CEC solar panels closest to LG Electronics Inc LG380N1K-E6 in nameplate wattage and Voc, starting with DualSun SAS DualSun 380M-120-01.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 380M-120-01
DualSun SAS
380.0 W Tie (0 W) 41.3 V 21.47% 93.9%
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC
Boviet Solar Technology Co Ltd
380.0 W Tie (0 W) 40.94 V 20.54% 94.2%
CSI Solar Co Ltd CS3L-385MS
CSI Solar Co Ltd
385.0 W +5.0 W 41.4 V 21.51% 93.2%
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W -5.0 W 41.2 V 20.95% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LG Electronics Inc LG380N1K-E6?

Evaluate LG Electronics Inc LG380N1K-E6 (380.0 W STC, 41.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LG Electronics Inc LG380N1K-E6 reaches 46.54 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 424 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (424 sq ft).
  • 2026 tax credit baseline: cash residential installs of LG Electronics Inc LG380N1K-E6 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LG Electronics Inc LG380N1K-E6 8 kW Residential Fit

Needs 22 modules (424 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 353.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LG Electronics Inc LG380N1K-E6 by LG Electronics Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LG Electronics Inc LG380N1K-E6?

Multiplying LG Electronics Inc LG380N1K-E6's 11.43 A short-circuit current by 1.56 equals 17.83 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can LG Electronics Inc LG380N1K-E6 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.47 V cold Voc at 14 F and handles 11.43 A Isc; string inverters cap LG Electronics Inc LG380N1K-E6 at 13 panels on 600 V.

Is LG Electronics Inc LG380N1K-E6 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LG Electronics Inc LG380N1K-E6 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?