Leapton Energy Co Ltd LP182*182-M-54-MH-410W is a 410.0 W STC (380.4 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.34 V Voc at 25 C, and 40.87 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 380.4 W
- Voc @ 25C
- 37.34 V
- Efficiency
- 21.13%
How Does Leapton Energy Co Ltd LP182*182-M-54-MH-410W Compare Against Peer CEC Listings?
How Leapton Energy Co Ltd Leapton Energy Co Ltd LP182*182-M-54-MH-410W handles rooftop heat (380.4 W PTC), 8 kW sizing, and cold winter string voltage.
Leapton Energy Co Ltd builds the Leapton Energy Co Ltd LP182*182-M-54-MH-410W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). Compared against Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W (410.0 W), this model holds strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677). Lower 37.34 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.37 A overcurrent floor served by a 25 A breaker.
Where Does Leapton Energy Co Ltd LP182*182-M-54-MH-410W Fall Across Listed CEC Models?
Where Leapton Energy Co Ltd LP182*182-M-54-MH-410W (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Leapton Energy Co Ltd LP182*182-M-54-MH-410W?
Percentile placement of Leapton Energy Co Ltd LP182*182-M-54-MH-410W across power density (211.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Leapton Energy Co Ltd LP182*182-M-54-MH-410W?
Four critical engineering numbers homeowners and solar installers check first when reviewing Leapton Energy Co Ltd LP182*182-M-54-MH-410W specifications.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.13% Aperture Efficiency
Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.87 V at -10 C (572.2 V string) and 41.88 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.34 * (1 + (-0.27/100) * (-10 - 25)) = 40.87 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for Leapton Energy Co Ltd LP182*182-M-54-MH-410W: Voc=37.34 V, beta_Voc=-0.27%/C, Isc=13.7 A, STC=410.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (572.2 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Leapton Energy Co Ltd LP182*182-M-54-MH-410W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Leapton Energy Co Ltd LP182*182-M-54-MH-410W.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 380.4 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.34 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.32 V / 13.06 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.27 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.13% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Leapton Energy Co Ltd LP182*182-M-54-MH-410W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Leapton Energy Co Ltd LP182*182-M-54-MH-410W (410.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 313 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 418 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 522 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Leapton Energy Co Ltd Series?
All closely matched Leapton Energy Co Ltd wattages and cosmetic trims sharing the Leapton Energy Co Ltd LP182*182-M-54-MH-410W architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Leapton Energy Co Ltd LP182*182-M-54-MH-400W | 400.0 W | 370.9 W | 36.94 V | 30.92 V | 20.62% |
| Leapton Energy Co Ltd LP182*182-M-54-MH-405W | 405.0 W | 375.6 W | 37.14 V | 31.12 V | 20.88% |
| Leapton Energy Co Ltd LP182*182-M-54-MH-410W | 410.0 W | 380.4 W | 37.34 V | 31.32 V | 21.13% |
| Leapton Energy Co Ltd LP182*182-M-54-MH-415W | 415.0 W | 385.2 W | 37.54 V | 31.62 V | 21.39% |
| Leapton Energy Co Ltd LP182*182-M-54-MH-420W | 420.0 W | 390.0 W | 37.74 V | 31.72 V | 21.65% |
How Many Leapton Energy Co Ltd LP182*182-M-54-MH-410W Modules Fit in a Cold-Weather String?
Maximum series module counts for Leapton Energy Co Ltd LP182*182-M-54-MH-410W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.88 V | 14 panels | 586.3 V | 23 panels |
| -10 C (14 F) | 40.87 V | 14 panels | 572.2 V | 24 panels |
| 0 C (32 F) | 39.86 V | 15 panels | 597.9 V | 25 panels |
| 25 C (77 F STC) | 37.34 V | 16 panels | 597.4 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Leapton Energy Co Ltd LP182*182-M-54-MH-410W?
Alternative CEC solar modules from competing brands near Leapton Energy Co Ltd LP182*182-M-54-MH-410W (410.0 W), including Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 37.34 V | 21.24% | 92.2% |
| Aptos Solar Technology LLC DNA-108-MF10-410W Aptos Solar Technology LLC |
410.0 W | Tie (0 W) | 37.32 V | 21.03% | 93.8% |
| CertainTeed CTM10410HC11-06 CertainTeed |
410.0 W | Tie (0 W) | 37.32 V | 21.03% | 93.8% |
| Elin Energy (Sirius PV) ELNSM54M-HC-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Leapton Energy Co Ltd LP182*182-M-54-MH-410W?
Evaluate Leapton Energy Co Ltd LP182*182-M-54-MH-410W (410.0 W STC, 37.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Leapton Energy Co Ltd LP182*182-M-54-MH-410W reaches 41.88 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Leapton Energy Co Ltd LP182*182-M-54-MH-410W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Leapton Energy Co Ltd LP182*182-M-54-MH-410W 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 380.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Leapton Energy Co Ltd LP182*182-M-54-MH-410W by Leapton Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Leapton Energy Co Ltd LP182*182-M-54-MH-410W?
Multiplying Leapton Energy Co Ltd LP182*182-M-54-MH-410W's 13.7 A short-circuit current by 1.56 equals 21.37 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Leapton Energy Co Ltd LP182*182-M-54-MH-410W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.87 V cold Voc at 14 F and handles 13.7 A Isc; string inverters cap Leapton Energy Co Ltd LP182*182-M-54-MH-410W at 14 panels on 600 V.
Is Leapton Energy Co Ltd LP182*182-M-54-MH-410W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Leapton Energy Co Ltd LP182*182-M-54-MH-410W rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)