KOSOL ENERGIE PVT LTD KE-515-72XS is a 515.0 W STC (484.0 W PTC) Mono-c-Si solar module ranking #4,316 of 21,677 CEC listings (top 20.2%; higher than 79.8% of peers). It delivers 19.96% efficiency, 48.4 V Voc at 25 C, and 52.7 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 515.0 W
- PTC Wattage
- 484.0 W
- Voc @ 25C
- 48.4 V
- Efficiency
- 19.96%
How Does KOSOL ENERGIE PVT LTD KE-515-72XS Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for KOSOL ENERGIE PVT LTD KE-515-72XS (Mono-c-Si) residential solar systems.
Homeowners evaluating KOSOL ENERGIE PVT LTD KE-515-72XS need 12 panels for 6 kW or 16 panels (444 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 16 panels (444 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.254%/C) pushes open-circuit voltage to 52.7 V at 14 F and 53.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does KOSOL ENERGIE PVT LTD KE-515-72XS Fall Across Listed CEC Models?
Comparison of KOSOL ENERGIE PVT LTD KE-515-72XS (515.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define KOSOL ENERGIE PVT LTD KE-515-72XS?
Relative ranking of KOSOL ENERGIE PVT LTD KE-515-72XS across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for KOSOL ENERGIE PVT LTD KE-515-72XS?
Summary of KOSOL ENERGIE PVT LTD KE-515-72XS output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.
Top 20.2% STC Output
515.0 W STC (+130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.96% Aperture Efficiency
Power density 199.6 W/m2 (0.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.7 V at -10 C (579.7 V string) and 53.93 V at -20 C (11 max).
16 Panels = 8,240 W STC
Occupies 41.3 m2 (444 sq ft) producing 7,744 W PTC; NEC 690.8 OCPD floor is 20.98 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.4 * (1 + (-0.254/100) * (-10 - 25)) = 52.7 V | OCPD = 1.56 * 13.45 = 20.98 A
Inputs from CEC Modules.csv for KOSOL ENERGIE PVT LTD KE-515-72XS: Voc=48.4 V, beta_Voc=-0.254%/C, Isc=13.45 A, STC=515.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (579.7 V); 16 panels for 8 kW (444 sq ft).
What Are the Published CEC Specifications for KOSOL ENERGIE PVT LTD KE-515-72XS?
Complete CEC test sheet for KOSOL ENERGIE PVT LTD KE-515-72XS including Isc (13.45 A), Voc (48.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 515.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 484.0 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.45 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.3 V / 12.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.254 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.96% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many KOSOL ENERGIE PVT LTD KE-515-72XS Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using KOSOL ENERGIE PVT LTD KE-515-72XS.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.18 kW | 333 sq ft | $1,547 | $2,616 |
| 8 kW Class | 16 | 8.24 kW | 444 sq ft | $2,062 | $3,487 |
| 10 kW Class | 20 | 10.3 kW | 555 sq ft | $2,578 | $4,359 |
Which Sibling Wattage & Trim Variants Belong to This KOSOL ENERGIE PVT LTD Series?
Related KOSOL ENERGIE PVT LTD power steps and black/silver trims consolidated into this KOSOL ENERGIE PVT LTD KE-515-72XS series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| KOSOL ENERGIE PVT LTD KE-510-72XS | 510.0 W | 479.2 W | 48.2 V | 40.2 V | 19.77% |
| KOSOL ENERGIE PVT LTD KE-515-72XS | 515.0 W | 484.0 W | 48.4 V | 40.3 V | 19.96% |
| KOSOL ENERGIE PVT LTD KE-520-72XS | 520.0 W | 488.8 W | 48.5 V | 40.5 V | 20.16% |
How Many KOSOL ENERGIE PVT LTD KE-515-72XS Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for KOSOL ENERGIE PVT LTD KE-515-72XS (48.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.93 V | 11 panels | 593.2 V | 18 panels |
| -10 C (14 F) | 52.7 V | 11 panels | 579.7 V | 18 panels |
| 0 C (32 F) | 51.47 V | 11 panels | 566.2 V | 19 panels |
| 25 C (77 F STC) | 48.4 V | 12 panels | 580.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to KOSOL ENERGIE PVT LTD KE-515-72XS?
Four comparable CEC modules such as DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M (520.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
520.0 W | +5.0 W | 48.33 V | 27.37% | 95.1% |
| BYD Company Limited BYD520MLTK-36 BYD Company Limited |
520.0 W | +5.0 W | 48.52 V | 20.16% | 92.9% |
| Heliene 144HC-520 M10 SL Heliene |
520.0 W | +5.0 W | 48.72 V | 20.88% | 93.4% |
| IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-520/M IMPERIAL STAR SOLAR(CAMBODIA) CO LTD |
520.0 W | +5.0 W | 48.88 V | 20.31% | 93.9% |
What Are the Design Limits and Best-Fit Uses for KOSOL ENERGIE PVT LTD KE-515-72XS?
Evaluate KOSOL ENERGIE PVT LTD KE-515-72XS (515.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), KOSOL ENERGIE PVT LTD KE-515-72XS reaches 53.93 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (444 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of KOSOL ENERGIE PVT LTD KE-515-72XS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
KOSOL ENERGIE PVT LTD KE-515-72XS 8 kW Residential Fit
Needs 16 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 484.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for KOSOL ENERGIE PVT LTD KE-515-72XS by KOSOL ENERGIE PVT LTD grounded in CEC test data and NEC 690.7/690.8 limits.
Why is KOSOL ENERGIE PVT LTD KE-515-72XS PTC wattage (484.0 W) lower than STC (515.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 484.0 W PTC (94.0% retention) across KOSOL ENERGIE PVT LTD KE-515-72XS's 2.58 m2 aperture.
Who should skip KOSOL ENERGIE PVT LTD KE-515-72XS on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 KOSOL ENERGIE PVT LTD KE-515-72XS panels (444 sq ft) leave unusable roof gaps vs. DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M.
What is the 1,000 V commercial string limit for KOSOL ENERGIE PVT LTD KE-515-72XS?
On 1,000 V commercial inverters at -10 C (52.7 V cold Voc), KOSOL ENERGIE PVT LTD KE-515-72XS fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)