Manufacturer: KOSOL ENERGIE PVT LTD Registry: CEC Verified Engineering Specification

KOSOL ENERGIE PVT LTD KE-515-72XS is a 515.0 W STC (484.0 W PTC) Mono-c-Si solar module ranking #4,316 of 21,677 CEC listings (top 20.2%; higher than 79.8% of peers). It delivers 19.96% efficiency, 48.4 V Voc at 25 C, and 52.7 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
515.0 W
PTC Wattage
484.0 W
Voc @ 25C
48.4 V
Efficiency
19.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does KOSOL ENERGIE PVT LTD KE-515-72XS Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for KOSOL ENERGIE PVT LTD KE-515-72XS (Mono-c-Si) residential solar systems.

Homeowners evaluating KOSOL ENERGIE PVT LTD KE-515-72XS need 12 panels for 6 kW or 16 panels (444 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 16 panels (444 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.254%/C) pushes open-circuit voltage to 52.7 V at 14 F and 53.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does KOSOL ENERGIE PVT LTD KE-515-72XS Fall Across Listed CEC Models?

Comparison of KOSOL ENERGIE PVT LTD KE-515-72XS (515.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where KOSOL ENERGIE PVT LTD KE-515-72XS (515.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCKOSOL ENERGIE PVT : 515.0 W

What Dataset Percentiles Define KOSOL ENERGIE PVT LTD KE-515-72XS?

Relative ranking of KOSOL ENERGIE PVT LTD KE-515-72XS across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.

KOSOL ENERGIE PVT LTD KE-515-72XS Engineering BenchmarksPercentile comparison of KOSOL ENERGIE PVT LTD KE-515-72XS wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage515.0 WPTC/STC Retention94.0%Module Efficiency19.96%

What Do the Dataset Ranks Show for KOSOL ENERGIE PVT LTD KE-515-72XS?

Summary of KOSOL ENERGIE PVT LTD KE-515-72XS output rank, 8 kW array size (16 panels), efficiency rating, and 600 V string limit.

Rank #4,316 / 21,677

Top 20.2% STC Output

515.0 W STC (+130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,625

19.96% Aperture Efficiency

Power density 199.6 W/m2 (0.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.7 V at -10 C (579.7 V string) and 53.93 V at -20 C (11 max).

8 kW Reference Array

16 Panels = 8,240 W STC

Occupies 41.3 m2 (444 sq ft) producing 7,744 W PTC; NEC 690.8 OCPD floor is 20.98 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.4 * (1 + (-0.254/100) * (-10 - 25)) = 52.7 V | OCPD = 1.56 * 13.45 = 20.98 A

Inputs from CEC Modules.csv for KOSOL ENERGIE PVT LTD KE-515-72XS: Voc=48.4 V, beta_Voc=-0.254%/C, Isc=13.45 A, STC=515.0 W, Area=2.58 m2.

Result: 11 panels max on 600 V (579.7 V); 16 panels for 8 kW (444 sq ft).

What Are the Published CEC Specifications for KOSOL ENERGIE PVT LTD KE-515-72XS?

Complete CEC test sheet for KOSOL ENERGIE PVT LTD KE-515-72XS including Isc (13.45 A), Voc (48.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for KOSOL ENERGIE PVT LTD KE-515-72XS.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 515.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 484.0 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.3 V / 12.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.254 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.96% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many KOSOL ENERGIE PVT LTD KE-515-72XS Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using KOSOL ENERGIE PVT LTD KE-515-72XS.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.18 kW 333 sq ft $1,547 $2,616
8 kW Class 16 8.24 kW 444 sq ft $2,062 $3,487
10 kW Class 20 10.3 kW 555 sq ft $2,578 $4,359

Which Sibling Wattage & Trim Variants Belong to This KOSOL ENERGIE PVT LTD Series?

Related KOSOL ENERGIE PVT LTD power steps and black/silver trims consolidated into this KOSOL ENERGIE PVT LTD KE-515-72XS series guide.

Sibling CEC listings grouped into the KOSOL ENERGIE PVT LTD KE-515-72XS wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
KOSOL ENERGIE PVT LTD KE-510-72XS 510.0 W 479.2 W 48.2 V 40.2 V 19.77%
KOSOL ENERGIE PVT LTD KE-515-72XS 515.0 W 484.0 W 48.4 V 40.3 V 19.96%
KOSOL ENERGIE PVT LTD KE-520-72XS 520.0 W 488.8 W 48.5 V 40.5 V 20.16%

How Many KOSOL ENERGIE PVT LTD KE-515-72XS Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for KOSOL ENERGIE PVT LTD KE-515-72XS (48.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.4V and beta_Voc=-0.254%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.93 V 11 panels 593.2 V 18 panels
-10 C (14 F) 52.7 V 11 panels 579.7 V 18 panels
0 C (32 F) 51.47 V 11 panels 566.2 V 19 panels
25 C (77 F STC) 48.4 V 12 panels 580.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to KOSOL ENERGIE PVT LTD KE-515-72XS?

Four comparable CEC modules such as DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M (520.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
520.0 W +5.0 W 48.33 V 27.37% 95.1%
BYD Company Limited BYD520MLTK-36
BYD Company Limited
520.0 W +5.0 W 48.52 V 20.16% 92.9%
Heliene 144HC-520 M10 SL
Heliene
520.0 W +5.0 W 48.72 V 20.88% 93.4%
IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-520/M
IMPERIAL STAR SOLAR(CAMBODIA) CO LTD
520.0 W +5.0 W 48.88 V 20.31% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for KOSOL ENERGIE PVT LTD KE-515-72XS?

Evaluate KOSOL ENERGIE PVT LTD KE-515-72XS (515.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), KOSOL ENERGIE PVT LTD KE-515-72XS reaches 53.93 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (444 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of KOSOL ENERGIE PVT LTD KE-515-72XS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

KOSOL ENERGIE PVT LTD KE-515-72XS 8 kW Residential Fit

Needs 16 modules (444 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 484.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for KOSOL ENERGIE PVT LTD KE-515-72XS by KOSOL ENERGIE PVT LTD grounded in CEC test data and NEC 690.7/690.8 limits.

Why is KOSOL ENERGIE PVT LTD KE-515-72XS PTC wattage (484.0 W) lower than STC (515.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 484.0 W PTC (94.0% retention) across KOSOL ENERGIE PVT LTD KE-515-72XS's 2.58 m2 aperture.

Who should skip KOSOL ENERGIE PVT LTD KE-515-72XS on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 16 KOSOL ENERGIE PVT LTD KE-515-72XS panels (444 sq ft) leave unusable roof gaps vs. DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M.

What is the 1,000 V commercial string limit for KOSOL ENERGIE PVT LTD KE-515-72XS?

On 1,000 V commercial inverters at -10 C (52.7 V cold Voc), KOSOL ENERGIE PVT LTD KE-515-72XS fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.