Jinko Solar Co Ltd JKMS245P-60 is a 245.0 W STC (221.0 W PTC) Multi-c-Si solar module ranking #19,942 of 21,677 CEC listings (below all-CEC median; higher than 7.0% of peers). It delivers 14.97% efficiency, 35.6 V Voc at 25 C, and 39.75 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 245.0 W
- PTC Wattage
- 221.0 W
- Voc @ 25C
- 35.6 V
- Efficiency
- 14.97%
How Does Jinko Solar Co Ltd JKMS245P-60 Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKMS245P-60 handles rooftop heat (221.0 W PTC), 8 kW sizing, and cold winter string voltage.
Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKMS245P-60 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 149.7 W/m2 (4.94 percentage points below 19.91% CEC median). Compared against Chinaland Solar Energy HSE245-60M (245.0 W), this model holds typical 90.2% PTC-to-STC thermal output (221.0 W real-world rating). Lower 35.6 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.4 A overcurrent floor served by a 15 A breaker.
Where Does Jinko Solar Co Ltd JKMS245P-60 Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKMS245P-60 (245.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKMS245P-60?
Percentile placement of Jinko Solar Co Ltd JKMS245P-60 across power density (149.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKMS245P-60?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKMS245P-60 specifications.
245.0 W STC · Higher Than 7.0%
245.0 W STC (-140.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.97% Aperture Efficiency
Power density 149.7 W/m2 (4.94 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 39.75 V at -10 C (596.2 V string) and 40.93 V at -20 C (14 max).
33 Panels = 8,085 W STC
Occupies 54.0 m2 (581 sq ft) producing 7,293 W PTC; NEC 690.8 OCPD floor is 14.4 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 35.6 * (1 + (-0.333/100) * (-10 - 25)) = 39.75 V | OCPD = 1.56 * 9.23 = 14.4 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKMS245P-60: Voc=35.6 V, beta_Voc=-0.333%/C, Isc=9.23 A, STC=245.0 W, Area=1.637 m2.
Result: 15 panels max on 600 V (596.2 V); 33 panels for 8 kW (581 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKMS245P-60?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKMS245P-60.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 245.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 221.0 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 35.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 28.6 V / 8.57 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.333 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.97% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKMS245P-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKMS245P-60 (245.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 25 | 6.12 kW | 441 sq ft | $1,532 | $2,590 |
| 8 kW Class | 33 | 8.09 kW | 581 sq ft | $2,025 | $3,424 |
| 10 kW Class | 41 | 10.04 kW | 722 sq ft | $2,513 | $4,249 |
How Many Jinko Solar Co Ltd JKMS245P-60 Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKMS245P-60 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 40.93 V | 14 panels | 573.0 V | 24 panels |
| -10 C (14 F) | 39.75 V | 15 panels | 596.2 V | 25 panels |
| 0 C (32 F) | 38.56 V | 15 panels | 578.4 V | 25 panels |
| 25 C (77 F STC) | 35.6 V | 16 panels | 569.6 V | 28 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKMS245P-60?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKMS245P-60 (245.0 W), including Chinaland Solar Energy HSE245-60M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE245-60M Chinaland Solar Energy |
245.0 W | Tie (0 W) | 36.8 V | 15.09% | 90.4% |
| Chinaland Solar Energy HSE245-60M-B Chinaland Solar Energy |
245.0 W | Tie (0 W) | 36.8 V | 14.33% | 90.2% |
| Chinaland Solar Energy HSE240-60P Chinaland Solar Energy |
240.0 W | -5.0 W | 35.7 V | 14.78% | 88.4% |
| Chinaland Solar Energy HSE240-60P-B Chinaland Solar Energy |
240.0 W | -5.0 W | 35.7 V | 14.04% | 88.8% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKMS245P-60?
Evaluate Jinko Solar Co Ltd JKMS245P-60 (245.0 W STC, 35.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKMS245P-60 reaches 40.93 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 33 panels for an 8 kW build require 581 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 33 panels (581 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKMS245P-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKMS245P-60 8 kW Residential Fit
Needs 33 modules (581 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare Chinaland Solar Energy HSE245-60M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 221.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKMS245P-60 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKMS245P-60?
Multiplying Jinko Solar Co Ltd JKMS245P-60's 9.23 A short-circuit current by 1.56 equals 14.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKMS245P-60 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 39.75 V cold Voc at 14 F and handles 9.23 A Isc; string inverters cap Jinko Solar Co Ltd JKMS245P-60 at 15 panels on 600 V.
Is Jinko Solar Co Ltd JKMS245P-60 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKMS245P-60 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)