Skip to main content
WireAndSun
Calculators
CEC PV Module

Jinko Solar Co Ltd JKM400M-72L — CEC Solar Module Specifications

Manufacturer: Jinko Solar Co Ltd Registry: CEC Verified Engineering Specification

Jinko Solar Co Ltd JKM400M-72L is a 400.0 W STC (368.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.83% efficiency, 49.8 V Voc at 25 C, and 55.22 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
368.2 W
Voc @ 25C
49.8 V
Efficiency
20.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jinko Solar Co Ltd JKM400M-72L Compare Against Peer CEC Listings?

Solar engineering breakdown for Jinko Solar Co Ltd JKM400M-72L: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 400.0 W STC and 368.2 W PTC, Jinko Solar Co Ltd JKM400M-72L sits +15.0 W vs all-CEC median (top 45.5%; higher than 54.5% of peers) among 21,677 listed modules. Power density reaches 208.3 W/m2 (0.92 percentage points above 19.91% CEC median). Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-400-H rates 400.0 W.

Where Does Jinko Solar Co Ltd JKM400M-72L Fall Across Listed CEC Models?

Distribution marker showing Jinko Solar Co Ltd JKM400M-72L (400.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jinko Solar Co Ltd JKM400M-72L (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJinko Solar Co Ltd: 400.0 W

What Dataset Percentiles Define Jinko Solar Co Ltd JKM400M-72L?

Dataset percentiles tracking Jinko Solar Co Ltd JKM400M-72L power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Jinko Solar Co Ltd JKM400M-72L Engineering BenchmarksPercentile comparison of Jinko Solar Co Ltd JKM400M-72L wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention92.0%Module Efficiency20.83%

What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM400M-72L?

Benchmark highlights for Jinko Solar Co Ltd JKM400M-72L covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,094

20.83% Aperture Efficiency

Power density 208.3 W/m2 (0.92 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.22 V at -10 C (552.2 V string) and 56.77 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,364 W PTC; NEC 690.8 OCPD floor is 16.16 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.311/100) * (-10 - 25)) = 55.22 V | OCPD = 1.56 * 10.36 = 16.16 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM400M-72L: Voc=49.8 V, beta_Voc=-0.311%/C, Isc=10.36 A, STC=400.0 W, Area=1.92 m2.

Result: 10 panels max on 600 V (552.2 V); 20 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM400M-72L?

Official CEC datasheet figures for Jinko Solar Co Ltd JKM400M-72L (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM400M-72L.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 368.2 W (92.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.7 V / 9.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.311 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.83% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Jinko Solar Co Ltd JKM400M-72L Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Jinko Solar Co Ltd JKM400M-72L modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 310 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 413 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 517 sq ft $2,503 $4,232

How Many Jinko Solar Co Ltd JKM400M-72L Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Jinko Solar Co Ltd JKM400M-72L (55.22 V at 14 F).

Computed from Voc=49.8V and beta_Voc=-0.311%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.77 V 10 panels 567.7 V 17 panels
-10 C (14 F) 55.22 V 10 panels 552.2 V 18 panels
0 C (32 F) 53.67 V 11 panels 590.4 V 18 panels
25 C (77 F STC) 49.8 V 12 panels 597.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM400M-72L?

Competing CEC solar panels closest to Jinko Solar Co Ltd JKM400M-72L in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM400M-72L?

Evaluate Jinko Solar Co Ltd JKM400M-72L (400.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM400M-72L reaches 56.77 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 413 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (413 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM400M-72L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jinko Solar Co Ltd JKM400M-72L 8 kW Residential Fit

Needs 20 modules (413 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 368.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM400M-72L by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Jinko Solar Co Ltd JKM400M-72L panels fit on a 600 V winter solar string?

At -10 C (14 F), Jinko Solar Co Ltd JKM400M-72L cold Voc rises from 49.8 V to 55.22 V (beta_Voc -0.311%/C), capping a 600 V string at 10 panels (552.2 V).

How much roof area does an 8 kW array of Jinko Solar Co Ltd JKM400M-72L need?

An 8 kW DC system uses 20 Jinko Solar Co Ltd JKM400M-72L modules (8,000 W STC / 7,364 W PTC), covering roughly 413 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Jinko Solar Co Ltd JKM400M-72L compare against Boviet Solar Technology Co Ltd BVM6612M-400-H?

Jinko Solar Co Ltd JKM400M-72L outputs 400.0 W STC (49.8 V Voc, rank #9,407 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-400-H delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.