Jinko Solar Co Ltd JKM360PP-72H is a 360.0 W STC (330.7 W PTC) Multi-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.95% efficiency, 48.5 V Voc at 25 C, and 54.27 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 330.7 W
- Voc @ 25C
- 48.5 V
- Efficiency
- 18.95%
How Does Jinko Solar Co Ltd JKM360PP-72H Compare Against Peer CEC Listings?
Solar engineering breakdown for Jinko Solar Co Ltd JKM360PP-72H: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Jinko Solar Co Ltd and peers, Jinko Solar Co Ltd JKM360PP-72H stands 81.2 W above the 278.8 W Multi-c-Si median and strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,532-$2,523/yr in baseline US bill offset. Higher 48.5 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Jinko Solar Co Ltd JKM360PP-72H Fall Across Listed CEC Models?
Distribution marker showing Jinko Solar Co Ltd JKM360PP-72H (360.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM360PP-72H?
Dataset percentiles tracking Jinko Solar Co Ltd JKM360PP-72H power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM360PP-72H?
Benchmark highlights for Jinko Solar Co Ltd JKM360PP-72H covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
18.95% Aperture Efficiency
Power density 189.5 W/m2 (0.96 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.27 V at -10 C (597.0 V string) and 55.92 V at -20 C (10 max).
23 Panels = 8,280 W STC
Occupies 43.7 m2 (470 sq ft) producing 7,606 W PTC; NEC 690.8 OCPD floor is 14.84 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.5 * (1 + (-0.34/100) * (-10 - 25)) = 54.27 V | OCPD = 1.56 * 9.51 = 14.84 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM360PP-72H: Voc=48.5 V, beta_Voc=-0.34%/C, Isc=9.51 A, STC=360.0 W, Area=1.9 m2.
Result: 11 panels max on 600 V (597.0 V); 23 panels for 8 kW (470 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM360PP-72H?
Official CEC datasheet figures for Jinko Solar Co Ltd JKM360PP-72H (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 330.7 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.1 V / 9.21 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.95% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 144 cells (Multi-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM360PP-72H Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Jinko Solar Co Ltd JKM360PP-72H modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 348 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 470 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 573 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Consolidated Jinko Solar Co Ltd wattage variants sharing the Jinko Solar Co Ltd JKM360PP-72H mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM350PP-72H | 350.0 W | 321.3 W | 48.0 V | 38.6 V | 18.42% |
| Jinko Solar Co Ltd JKM355PP-72H | 355.0 W | 326.0 W | 48.2 V | 38.9 V | 18.68% |
| Jinko Solar Co Ltd JKM360PP-72H | 360.0 W | 330.7 W | 48.5 V | 39.1 V | 18.95% |
| Jinko Solar Co Ltd JKM365PP-72H | 365.0 W | 335.5 W | 48.8 V | 39.3 V | 19.21% |
| Jinko Solar Co Ltd JKM370PP-72H | 370.0 W | 340.2 W | 49.1 V | 39.5 V | 19.47% |
How Many Jinko Solar Co Ltd JKM360PP-72H Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Jinko Solar Co Ltd JKM360PP-72H (54.27 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.92 V | 10 panels | 559.2 V | 17 panels |
| -10 C (14 F) | 54.27 V | 11 panels | 597.0 V | 18 panels |
| 0 C (32 F) | 52.62 V | 11 panels | 578.8 V | 19 panels |
| 25 C (77 F STC) | 48.5 V | 12 panels | 582.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM360PP-72H?
Competing CEC solar panels closest to Jinko Solar Co Ltd JKM360PP-72H in nameplate wattage and Voc, starting with DEHUI SOLAR POWER INC DH-72M-360W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DEHUI SOLAR POWER INC DH-72M-360W DEHUI SOLAR POWER INC |
360.0 W | Tie (0 W) | 49.1 V | 18.72% | 91.4% |
| Advance Power API-M360 Advance Power |
360.0 W | Tie (0 W) | 47.56 V | 18.56% | 91.7% |
| Auxin Solar AXN6M612T360 Auxin Solar |
360.0 W | Tie (0 W) | 47.56 V | 18.55% | 91.7% |
| Boviet Solar Technology Co Ltd BVM6612M-360 Boviet Solar Technology Co Ltd |
360.0 W | Tie (0 W) | 47.5 V | 18.56% | 92.3% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM360PP-72H?
Evaluate Jinko Solar Co Ltd JKM360PP-72H (360.0 W STC, 48.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM360PP-72H reaches 55.92 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (470 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM360PP-72H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM360PP-72H 8 kW Residential Fit
Needs 23 modules (470 sq ft) with a 15 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72M-360W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 330.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM360PP-72H by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM360PP-72H?
Multiplying Jinko Solar Co Ltd JKM360PP-72H's 9.51 A short-circuit current by 1.56 equals 14.84 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKM360PP-72H pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.27 V cold Voc at 14 F and handles 9.51 A Isc; string inverters cap Jinko Solar Co Ltd JKM360PP-72H at 11 panels on 600 V.
Is Jinko Solar Co Ltd JKM360PP-72H eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM360PP-72H rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)