Jinko Solar Co Ltd JKM355M-72B-J4 is a 355.0 W STC (324.3 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 19.34% efficiency, 47.8 V Voc at 25 C, and 52.95 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 355.0 W
- PTC Wattage
- 324.3 W
- Voc @ 25C
- 47.8 V
- Efficiency
- 19.34%
How Does Jinko Solar Co Ltd JKM355M-72B-J4 Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM355M-72B-J4 handles rooftop heat (324.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Jinko Solar Co Ltd JKM355M-72B-J4 exhibits 9.45 A short-circuit current, requiring a 14.74 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #12,724 of 21,677 (55.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 42.2 m2 for an 8 kW system (29 panels for 10 kW). Mid-range 47.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Jinko Solar Co Ltd JKM355M-72B-J4 Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKM355M-72B-J4 (355.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM355M-72B-J4?
Percentile placement of Jinko Solar Co Ltd JKM355M-72B-J4 across power density (193.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM355M-72B-J4?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM355M-72B-J4 specifications.
355.0 W STC · Higher Than 39.9%
355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.34% Aperture Efficiency
Power density 193.5 W/m2 (0.57 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.95 V at -10 C (582.5 V string) and 54.43 V at -20 C (11 max).
23 Panels = 8,165 W STC
Occupies 42.2 m2 (454 sq ft) producing 7,459 W PTC; NEC 690.8 OCPD floor is 14.74 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.8 * (1 + (-0.308/100) * (-10 - 25)) = 52.95 V | OCPD = 1.56 * 9.45 = 14.74 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM355M-72B-J4: Voc=47.8 V, beta_Voc=-0.308%/C, Isc=9.45 A, STC=355.0 W, Area=1.835 m2.
Result: 11 panels max on 600 V (582.5 V); 23 panels for 8 kW (454 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM355M-72B-J4?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM355M-72B-J4.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 355.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 324.3 W (91.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.45 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.3 V / 9.04 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.308 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.34% (1.835 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM355M-72B-J4 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM355M-72B-J4 (355.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.04 kW | 336 sq ft | $1,512 | $2,556 |
| 8 kW Class | 23 | 8.16 kW | 454 sq ft | $2,042 | $3,454 |
| 10 kW Class | 29 | 10.29 kW | 573 sq ft | $2,575 | $4,355 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKM355M-72B-J4 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM350M-72B-J4 | 350.0 W | 319.6 W | 47.5 V | 39.1 V | 19.07% |
| Jinko Solar Co Ltd JKM355M-72B-J4 | 355.0 W | 324.3 W | 47.8 V | 39.3 V | 19.34% |
How Many Jinko Solar Co Ltd JKM355M-72B-J4 Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKM355M-72B-J4 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.43 V | 11 panels | 598.7 V | 18 panels |
| -10 C (14 F) | 52.95 V | 11 panels | 582.5 V | 18 panels |
| 0 C (32 F) | 51.48 V | 11 panels | 566.3 V | 19 panels |
| 25 C (77 F STC) | 47.8 V | 12 panels | 573.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM355M-72B-J4?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM355M-72B-J4 (355.0 W), including Bluesun Solar Energy Tech CoLtd BSM355P-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM355P-72 Bluesun Solar Energy Tech CoLtd |
355.0 W | Tie (0 W) | 47.52 V | 18.32% | 91.6% |
| AXITEC AC-355M/156-72S AXITEC |
355.0 W | Tie (0 W) | 47.4 V | 18.3% | 91.5% |
| Boviet Solar Technology Co Ltd BVM6612P-355 Boviet Solar Technology Co Ltd |
355.0 W | Tie (0 W) | 47.3 V | 18.3% | 92.6% |
| CertainTeed CT355M00-01 CertainTeed |
355.0 W | Tie (0 W) | 47.3 V | 19.61% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM355M-72B-J4?
Evaluate Jinko Solar Co Ltd JKM355M-72B-J4 (355.0 W STC, 47.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM355M-72B-J4 reaches 54.43 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 454 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (454 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM355M-72B-J4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM355M-72B-J4 8 kW Residential Fit
Needs 23 modules (454 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM355P-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 324.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM355M-72B-J4 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jinko Solar Co Ltd JKM355M-72B-J4 PTC wattage (324.3 W) lower than STC (355.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 324.3 W PTC (91.4% retention) across Jinko Solar Co Ltd JKM355M-72B-J4's 1.835 m2 aperture.
Who should skip Jinko Solar Co Ltd JKM355M-72B-J4 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 Jinko Solar Co Ltd JKM355M-72B-J4 panels (454 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM355P-72.
What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM355M-72B-J4?
On 1,000 V commercial inverters at -10 C (52.95 V cold Voc), Jinko Solar Co Ltd JKM355M-72B-J4 fits up to 18 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)