Skip to main content
WireAndSun
Calculators
CEC PV Module

Jinko Solar Co Ltd JKM335PP-72-V — CEC Solar Module Specifications

Manufacturer: Jinko Solar Co Ltd Registry: CEC Verified Engineering Specification

Jinko Solar Co Ltd JKM335PP-72-V is a 335.0 W STC (305.0 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.82% efficiency, 47.2 V Voc at 25 C, and 52.78 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
305.0 W
Voc @ 25C
47.2 V
Efficiency
17.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jinko Solar Co Ltd JKM335PP-72-V Compare Against Peer CEC Listings?

Engineering position of Jinko Solar Co Ltd JKM335PP-72-V (335.0 W STC) vs. BYD Company Limited BYD335P6K-36 across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, Jinko Solar Co Ltd JKM335PP-72-V pairs typical 91.0% PTC-to-STC thermal output (305.0 W real-world rating) with 47.2 V nominal Voc. An 8 kW residential build (8,040 W DC, 7,320 W PTC) saves ~$2,012/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer BYD Company Limited BYD335P6K-36 offers a 335.0 W alternative.

Where Does Jinko Solar Co Ltd JKM335PP-72-V Fall Across Listed CEC Models?

Plots Jinko Solar Co Ltd JKM335PP-72-V at 335.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jinko Solar Co Ltd JKM335PP-72-V (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJinko Solar Co Ltd: 335.0 W

What Dataset Percentiles Define Jinko Solar Co Ltd JKM335PP-72-V?

Benchmarks Jinko Solar Co Ltd JKM335PP-72-V on STC wattage, thermal PTC/STC retention, and 17.82 aperture conversion efficiency against CEC peers.

Jinko Solar Co Ltd JKM335PP-72-V Engineering BenchmarksPercentile comparison of Jinko Solar Co Ltd JKM335PP-72-V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention91.0%Module Efficiency17.82%

What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM335PP-72-V?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Jinko Solar Co Ltd JKM335PP-72-V by Jinko Solar Co Ltd.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,344

17.82% Aperture Efficiency

Power density 178.2 W/m2 (2.09 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.78 V at -10 C (580.6 V string) and 54.38 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 45.1 m2 (486 sq ft) producing 7,320 W PTC; NEC 690.8 OCPD floor is 14.32 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.2 * (1 + (-0.338/100) * (-10 - 25)) = 52.78 V | OCPD = 1.56 * 9.18 = 14.32 A

Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM335PP-72-V: Voc=47.2 V, beta_Voc=-0.338%/C, Isc=9.18 A, STC=335.0 W, Area=1.88 m2.

Result: 11 panels max on 600 V (580.6 V); 24 panels for 8 kW (486 sq ft).

What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM335PP-72-V?

Laboratory test ratings recorded for Jinko Solar Co Ltd JKM335PP-72-V (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Jinko Solar Co Ltd JKM335PP-72-V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 305.0 W (91.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.18 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.0 V / 8.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.338 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.82% (1.88 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Jinko Solar Co Ltd JKM335PP-72-V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (486 sq ft at 8 kW), and estimated Year-1 electric bill offset for Jinko Solar Co Ltd JKM335PP-72-V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 364 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 486 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 607 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?

Sibling wattage bins and frame colors grouped with Jinko Solar Co Ltd JKM335PP-72-V under Jinko Solar Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Jinko Solar Co Ltd JKM335PP-72-V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Jinko Solar Co Ltd JKM325PP-72-V 325.0 W 297.6 W 46.7 V 37.6 V 17.71%
Jinko Solar Co Ltd JKM330PP-72-V 330.0 W 302.3 W 46.9 V 37.8 V 17.98%
Jinko Solar Co Ltd JKM335PP-72-V 335.0 W 305.0 W 47.2 V 38.0 V 17.82%
Jinko Solar Co Ltd JKM340PP-72-V 340.0 W 309.7 W 47.5 V 38.2 V 18.09%
Jinko Solar Co Ltd JKM345PP-72-V 345.0 W 314.4 W 47.8 V 38.4 V 18.35%

How Many Jinko Solar Co Ltd JKM335PP-72-V Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Jinko Solar Co Ltd JKM335PP-72-V (beta_Voc -0.338%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.2V and beta_Voc=-0.338%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.38 V 11 panels 598.2 V 18 panels
-10 C (14 F) 52.78 V 11 panels 580.6 V 18 panels
0 C (32 F) 51.19 V 11 panels 563.1 V 19 panels
25 C (77 F STC) 47.2 V 12 panels 566.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM335PP-72-V?

Closest cross-brand CEC competitors to Jinko Solar Co Ltd JKM335PP-72-V matched near 335.0 W STC and 47.2 V Voc, led by BYD Company Limited BYD335P6K-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD335P6K-36
BYD Company Limited
335.0 W Tie (0 W) 47.28 V 17.27% 91.8%
Auxin Solar AXN6M612T335
Auxin Solar
335.0 W Tie (0 W) 47.04 V 17.26% 91.7%
Bluesun Solar Energy Tech CoLtd BSM335P-72
Bluesun Solar Energy Tech CoLtd
335.0 W Tie (0 W) 46.76 V 17.29% 91.4%
Centrosolar America EM72 335BW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM335PP-72-V?

Evaluate Jinko Solar Co Ltd JKM335PP-72-V (335.0 W STC, 47.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM335PP-72-V reaches 54.38 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 486 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (486 sq ft).
  • 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM335PP-72-V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jinko Solar Co Ltd JKM335PP-72-V 8 kW Residential Fit

Needs 24 modules (486 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD335P6K-36.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 305.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jinko Solar Co Ltd JKM335PP-72-V by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM335PP-72-V?

Multiplying Jinko Solar Co Ltd JKM335PP-72-V's 9.18 A short-circuit current by 1.56 equals 14.32 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Jinko Solar Co Ltd JKM335PP-72-V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.78 V cold Voc at 14 F and handles 9.18 A Isc; string inverters cap Jinko Solar Co Ltd JKM335PP-72-V at 11 panels on 600 V.

Is Jinko Solar Co Ltd JKM335PP-72-V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM335PP-72-V rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.