Jinko Solar Co Ltd JKM335M-60HBL is a 335.0 W STC (308.5 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 20.55% efficiency, 40.8 V Voc at 25 C, and 45.13 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 335.0 W
- PTC Wattage
- 308.5 W
- Voc @ 25C
- 40.8 V
- Efficiency
- 20.55%
How Does Jinko Solar Co Ltd JKM335M-60HBL Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM335M-60HBL handles rooftop heat (308.5 W PTC), 8 kW sizing, and cold winter string voltage.
Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKM335M-60HBL (Mono-c-Si) as a compact residential or specialty off-grid module delivering 205.5 W/m2 (0.64 percentage points above 19.91% CEC median). Compared against Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W (335.0 W), this model holds strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Mid-range 40.8 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 16.74 A overcurrent floor served by a 20 A breaker.
Where Does Jinko Solar Co Ltd JKM335M-60HBL Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKM335M-60HBL (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM335M-60HBL?
Percentile placement of Jinko Solar Co Ltd JKM335M-60HBL across power density (205.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM335M-60HBL?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM335M-60HBL specifications.
335.0 W STC · Higher Than 34.7%
335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.55% Aperture Efficiency
Power density 205.5 W/m2 (0.64 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.13 V at -10 C (586.7 V string) and 46.36 V at -20 C (12 max).
24 Panels = 8,040 W STC
Occupies 39.1 m2 (421 sq ft) producing 7,404 W PTC; NEC 690.8 OCPD floor is 16.74 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.8 * (1 + (-0.303/100) * (-10 - 25)) = 45.13 V | OCPD = 1.56 * 10.73 = 16.74 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM335M-60HBL: Voc=40.8 V, beta_Voc=-0.303%/C, Isc=10.73 A, STC=335.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (586.7 V); 24 panels for 8 kW (421 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM335M-60HBL?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM335M-60HBL.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 308.5 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.74 V / 9.93 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.303 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.55% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 20 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM335M-60HBL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM335M-60HBL (335.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.03 kW | 316 sq ft | $1,509 | $2,552 |
| 8 kW Class | 24 | 8.04 kW | 421 sq ft | $2,012 | $3,403 |
| 10 kW Class | 30 | 10.05 kW | 526 sq ft | $2,515 | $4,253 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKM335M-60HBL architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM325M-60HBL | 325.0 W | 298.8 W | 41.1 V | 33.6 V | 20.06% |
| Jinko Solar Co Ltd JKM330M-60HBL | 330.0 W | 303.7 W | 40.6 V | 33.54 V | 20.25% |
| Jinko Solar Co Ltd JKM335M-60HBL | 335.0 W | 308.5 W | 40.8 V | 33.74 V | 20.55% |
| Jinko Solar Co Ltd JKM340M-60HBL | 340.0 W | 313.2 W | 41.0 V | 33.93 V | 20.86% |
| Jinko Solar Co Ltd JKM345M-60HBL | 345.0 W | 318.0 W | 41.2 V | 34.12 V | 21.17% |
How Many Jinko Solar Co Ltd JKM335M-60HBL Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKM335M-60HBL from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.36 V | 12 panels | 556.3 V | 21 panels |
| -10 C (14 F) | 45.13 V | 13 panels | 586.7 V | 22 panels |
| 0 C (32 F) | 43.89 V | 13 panels | 570.6 V | 22 panels |
| 25 C (77 F STC) | 40.8 V | 14 panels | 571.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM335M-60HBL?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM335M-60HBL (335.0 W), including Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W Dehui Solar Power (Vietnam) CoLtd |
335.0 W | Tie (0 W) | 40.8 V | 20.81% | 93.0% |
| Auxin Solar AXNG1M335B Auxin Solar |
335.0 W | Tie (0 W) | 40.75 V | 20.43% | 93.2% |
| Dehui Solar Power (Vietnam) CoLtd DH-M860W 335W Dehui Solar Power (Vietnam) CoLtd |
335.0 W | Tie (0 W) | 40.7 V | 21.07% | 92.6% |
| Aptos Solar Technology LLC DNA-120-MF23-335W {Blk} Aptos Solar Technology LLC |
335.0 W | Tie (0 W) | 40.44 V | 19.85% | 90.8% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM335M-60HBL?
Evaluate Jinko Solar Co Ltd JKM335M-60HBL (335.0 W STC, 40.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM335M-60HBL reaches 46.36 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 421 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (421 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM335M-60HBL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM335M-60HBL 8 kW Residential Fit
Needs 24 modules (421 sq ft) with a 20 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 308.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM335M-60HBL by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM335M-60HBL?
Multiplying Jinko Solar Co Ltd JKM335M-60HBL's 10.73 A short-circuit current by 1.56 equals 16.74 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKM335M-60HBL pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.13 V cold Voc at 14 F and handles 10.73 A Isc; string inverters cap Jinko Solar Co Ltd JKM335M-60HBL at 13 panels on 600 V.
Is Jinko Solar Co Ltd JKM335M-60HBL eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM335M-60HBL rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)