Jinko Solar Co Ltd JKM330M-60L is a 330.0 W STC (304.0 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 20.75% efficiency, 41.3 V Voc at 25 C, and 45.84 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 304.0 W
- Voc @ 25C
- 41.3 V
- Efficiency
- 20.75%
How Does Jinko Solar Co Ltd JKM330M-60L Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM330M-60L (Mono-c-Si) residential solar systems.
Homeowners evaluating Jinko Solar Co Ltd JKM330M-60L need 19 panels for 6 kW or 25 panels (428 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (428 sq ft). Under NEC 690.7(A), beta_Voc (-0.314%/C) pushes open-circuit voltage to 45.84 V at 14 F and 47.14 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Jinko Solar Co Ltd JKM330M-60L Fall Across Listed CEC Models?
Comparison of Jinko Solar Co Ltd JKM330M-60L (330.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM330M-60L?
Relative ranking of Jinko Solar Co Ltd JKM330M-60L across nameplate watts, 92.1% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM330M-60L?
Summary of Jinko Solar Co Ltd JKM330M-60L output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.75% Aperture Efficiency
Power density 207.5 W/m2 (0.84 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.84 V at -10 C (595.9 V string) and 47.14 V at -20 C (12 max).
25 Panels = 8,250 W STC
Occupies 39.8 m2 (428 sq ft) producing 7,600 W PTC; NEC 690.8 OCPD floor is 16.08 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.3 * (1 + (-0.314/100) * (-10 - 25)) = 45.84 V | OCPD = 1.56 * 10.31 = 16.08 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM330M-60L: Voc=41.3 V, beta_Voc=-0.314%/C, Isc=10.31 A, STC=330.0 W, Area=1.59 m2.
Result: 13 panels max on 600 V (595.9 V); 25 panels for 8 kW (428 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM330M-60L?
Complete CEC test sheet for Jinko Solar Co Ltd JKM330M-60L including Isc (10.31 A), Voc (41.3 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 304.0 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.8 V / 9.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.314 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.75% (1.59 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM330M-60L Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM330M-60L.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 325 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 428 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 531 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM330M-60L series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM325M-60L | 325.0 W | 299.2 W | 41.1 V | 33.6 V | 20.44% |
| Jinko Solar Co Ltd JKM330M-60L | 330.0 W | 304.0 W | 41.3 V | 33.8 V | 20.75% |
How Many Jinko Solar Co Ltd JKM330M-60L Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM330M-60L (41.3 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.14 V | 12 panels | 565.7 V | 21 panels |
| -10 C (14 F) | 45.84 V | 13 panels | 595.9 V | 21 panels |
| 0 C (32 F) | 44.54 V | 13 panels | 579.0 V | 22 panels |
| 25 C (77 F STC) | 41.3 V | 14 panels | 578.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM330M-60L?
Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6610M-330L-H (330.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6610M-330L-H Boviet Solar Technology Co Ltd |
330.0 W | Tie (0 W) | 41.9 V | 19.76% | 93.6% |
| Boviet Solar Technology Co Ltd BVM6610M-330-H Boviet Solar Technology Co Ltd |
330.0 W | Tie (0 W) | 41.95 V | 20.25% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-330-H Boviet Solar Technology Co Ltd |
330.0 W | Tie (0 W) | 41.95 V | 20.28% | 93.2% |
| CSI Solar Co Ltd CS3K-330MS CSI Solar Co Ltd |
330.0 W | Tie (0 W) | 40.5 V | 20.62% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM330M-60L?
Evaluate Jinko Solar Co Ltd JKM330M-60L (330.0 W STC, 41.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM330M-60L reaches 47.14 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 428 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (428 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM330M-60L carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM330M-60L 8 kW Residential Fit
Needs 25 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6610M-330L-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 304.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM330M-60L by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Jinko Solar Co Ltd JKM330M-60L PTC wattage (304.0 W) lower than STC (330.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 304.0 W PTC (92.1% retention) across Jinko Solar Co Ltd JKM330M-60L's 1.59 m2 aperture.
Who should skip Jinko Solar Co Ltd JKM330M-60L on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 Jinko Solar Co Ltd JKM330M-60L panels (428 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6610M-330L-H.
What is the 1,000 V commercial string limit for Jinko Solar Co Ltd JKM330M-60L?
On 1,000 V commercial inverters at -10 C (45.84 V cold Voc), Jinko Solar Co Ltd JKM330M-60L fits up to 21 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)