Jinko Solar Co Ltd JKM310M-72B is a 310.0 W STC (280.0 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.98% efficiency, 45.9 V Voc at 25 C, and 51.09 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 280.0 W
- Voc @ 25C
- 45.9 V
- Efficiency
- 15.98%
How Does Jinko Solar Co Ltd JKM310M-72B Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKM310M-72B handles rooftop heat (280.0 W PTC), 8 kW sizing, and cold winter string voltage.
Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKM310M-72B (Mono-c-Si) as a compact residential or specialty off-grid module delivering 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612P-310 (310.0 W), this model holds typical 90.3% PTC-to-STC thermal output (280.0 W real-world rating). Mid-range 45.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.73 A overcurrent floor served by a 15 A breaker.
Where Does Jinko Solar Co Ltd JKM310M-72B Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKM310M-72B (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM310M-72B?
Percentile placement of Jinko Solar Co Ltd JKM310M-72B across power density (159.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM310M-72B?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKM310M-72B specifications.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.98% Aperture Efficiency
Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.09 V at -10 C (562.0 V string) and 52.57 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,280 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.9 * (1 + (-0.323/100) * (-10 - 25)) = 51.09 V | OCPD = 1.56 * 8.8 = 13.73 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM310M-72B: Voc=45.9 V, beta_Voc=-0.323%/C, Isc=8.8 A, STC=310.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (562.0 V); 26 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM310M-72B?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKM310M-72B.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 280.0 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.4 V / 8.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.323 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.98% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM310M-72B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKM310M-72B (310.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 418 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 689 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKM310M-72B architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM300M-72B | 300.0 W | 270.7 W | 45.5 V | 37.0 V | 15.46% |
| Jinko Solar Co Ltd JKM305M-72B | 305.0 W | 275.3 W | 45.7 V | 37.2 V | 15.72% |
| Jinko Solar Co Ltd JKM310M-72B | 310.0 W | 280.0 W | 45.9 V | 37.4 V | 15.98% |
| Jinko Solar Co Ltd JKM315M-72B | 315.0 W | 284.6 W | 46.1 V | 37.6 V | 16.23% |
| Jinko Solar Co Ltd JKM320M-72B | 320.0 W | 289.3 W | 46.3 V | 37.8 V | 16.49% |
How Many Jinko Solar Co Ltd JKM310M-72B Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKM310M-72B from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.57 V | 11 panels | 578.3 V | 19 panels |
| -10 C (14 F) | 51.09 V | 11 panels | 562.0 V | 19 panels |
| 0 C (32 F) | 49.61 V | 12 panels | 595.3 V | 20 panels |
| 25 C (77 F STC) | 45.9 V | 13 panels | 596.7 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM310M-72B?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKM310M-72B (310.0 W), including Boviet Solar Technology Co Ltd BVM6612P-310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612P-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| Centrosolar America CP72 310-C1 Centrosolar America |
310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| BYD Company Limited BYD 310P6C-36 BYD Company Limited |
310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.2% |
| BYD Company Limited BYD310P6K-36 BYD Company Limited |
310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.6% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM310M-72B?
Evaluate Jinko Solar Co Ltd JKM310M-72B (310.0 W STC, 45.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM310M-72B reaches 52.57 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM310M-72B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM310M-72B 8 kW Residential Fit
Needs 26 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 280.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM310M-72B by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKM310M-72B?
Multiplying Jinko Solar Co Ltd JKM310M-72B's 8.8 A short-circuit current by 1.56 equals 13.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKM310M-72B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.09 V cold Voc at 14 F and handles 8.8 A Isc; string inverters cap Jinko Solar Co Ltd JKM310M-72B at 11 panels on 600 V.
Is Jinko Solar Co Ltd JKM310M-72B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKM310M-72B rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)