Skip to main content
WireAndSun
Calculators
CEC PV Module

Jetion Solar (China) JT260PPg — CEC Solar Module Specifications

Manufacturer: Jetion Solar (China) Registry: CEC Verified Engineering Specification

Jetion Solar (China) JT260PPg is a 260.0 W STC (232.7 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.98% efficiency, 38.0 V Voc at 25 C, and 42.64 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
232.7 W
Voc @ 25C
38.0 V
Efficiency
15.98%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jetion Solar (China) JT260PPg Compare Against Peer CEC Listings?

How Jetion Solar (China) Jetion Solar (China) JT260PPg handles rooftop heat (232.7 W PTC), 8 kW sizing, and cold winter string voltage.

Jetion Solar (China) builds the Jetion Solar (China) JT260PPg (Multi-c-Si) as a compact residential or specialty off-grid module delivering 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). Compared against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W (260.0 W), this model holds typical 89.5% PTC-to-STC thermal output (232.7 W real-world rating). Lower 38.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.01 A overcurrent floor served by a 15 A breaker.

Where Does Jetion Solar (China) JT260PPg Fall Across Listed CEC Models?

Where Jetion Solar (China) JT260PPg (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Jetion Solar (China) JT260PPg (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJetion Solar (Chin: 260.0 W

What Dataset Percentiles Define Jetion Solar (China) JT260PPg?

Percentile placement of Jetion Solar (China) JT260PPg across power density (159.8 W/m2), thermal retention, and nameplate STC wattage.

Jetion Solar (China) JT260PPg Engineering BenchmarksPercentile comparison of Jetion Solar (China) JT260PPg wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention89.5%Module Efficiency15.98%

What Do the Dataset Ranks Show for Jetion Solar (China) JT260PPg?

Four critical engineering numbers homeowners and solar installers check first when reviewing Jetion Solar (China) JT260PPg specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,143

15.98% Aperture Efficiency

Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.64 V at -10 C (597.0 V string) and 43.97 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,214 W PTC; NEC 690.8 OCPD floor is 14.01 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.0 * (1 + (-0.349/100) * (-10 - 25)) = 42.64 V | OCPD = 1.56 * 8.98 = 14.01 A

Inputs from CEC Modules.csv for Jetion Solar (China) JT260PPg: Voc=38.0 V, beta_Voc=-0.349%/C, Isc=8.98 A, STC=260.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (597.0 V); 31 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for Jetion Solar (China) JT260PPg?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jetion Solar (China) JT260PPg.

Official California Energy Commission (NREL SAM) test parameters for Jetion Solar (China) JT260PPg.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 232.7 W (89.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.9 V / 8.44 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.349 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.98% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Jetion Solar (China) JT260PPg Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jetion Solar (China) JT260PPg (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 420 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 543 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 683 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Jetion Solar (China) Series?

All closely matched Jetion Solar (China) wattages and cosmetic trims sharing the Jetion Solar (China) JT260PPg architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Jetion Solar (China) JT260PPg wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Jetion Solar (China) JT250PPg 250.0 W 223.5 W 37.6 V 30.3 V 15.37%
Jetion Solar (China) JT255PPg 255.0 W 228.1 W 37.8 V 30.6 V 15.67%
Jetion Solar (China) JT260PPg 260.0 W 232.7 W 38.0 V 30.9 V 15.98%
Jetion Solar (China) JT265PPg 265.0 W 237.3 W 38.2 V 31.2 V 16.29%
Jetion Solar (China) JT270PPg 270.0 W 242.0 W 38.4 V 31.5 V 16.6%

How Many Jetion Solar (China) JT260PPg Modules Fit in a Cold-Weather String?

Maximum series module counts for Jetion Solar (China) JT260PPg from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.0V and beta_Voc=-0.349%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.97 V 13 panels 571.6 V 22 panels
-10 C (14 F) 42.64 V 14 panels 597.0 V 23 panels
0 C (32 F) 41.32 V 14 panels 578.5 V 24 panels
25 C (77 F STC) 38.0 V 15 panels 570.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Jetion Solar (China) JT260PPg?

Alternative CEC solar modules from competing brands near Jetion Solar (China) JT260PPg (260.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
260.0 W Tie (0 W) 38.0 V 16.01% 88.5%
Chinaland Solar Energy HSE260-60M
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 16.01% 90.5%
Chinaland Solar Energy HSE260-60M-B
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 15.21% 90.4%
GermanSolar USA GSP6-60-260W
GermanSolar USA
260.0 W Tie (0 W) 38.0 V 15.98% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Jetion Solar (China) JT260PPg?

Evaluate Jetion Solar (China) JT260PPg (260.0 W STC, 38.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Jetion Solar (China) JT260PPg reaches 43.97 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
  • 2026 tax credit baseline: cash residential installs of Jetion Solar (China) JT260PPg carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Jetion Solar (China) JT260PPg 8 kW Residential Fit

Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Jetion Solar (China) JT260PPg by Jetion Solar (China) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Jetion Solar (China) JT260PPg?

Multiplying Jetion Solar (China) JT260PPg's 8.98 A short-circuit current by 1.56 equals 14.01 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Jetion Solar (China) JT260PPg pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.64 V cold Voc at 14 F and handles 8.98 A Isc; string inverters cap Jetion Solar (China) JT260PPg at 14 panels on 600 V.

Is Jetion Solar (China) JT260PPg eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jetion Solar (China) JT260PPg rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.