Skip to main content
WireAndSun
Calculators
CEC PV Module

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG — CEC Solar Module Specifications

Manufacturer: HYUNDAI ENERGY SOLUTIONS CO LTD Registry: CEC Verified Engineering Specification

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG is a 375.0 W STC (350.9 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.59% efficiency, 41.24 V Voc at 25 C, and 45.21 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
350.9 W
Voc @ 25C
41.24 V
Efficiency
20.59%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG Compare Against Peer CEC Listings?

Solar engineering breakdown for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 375.0 W STC and 350.9 W PTC, HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG sits -10.0 W vs all-CEC median (below all-CEC median; higher than 46.0% of peers) among 21,677 listed modules. Power density reaches 205.8 W/m2 (0.68 percentage points above 19.91% CEC median). Mid-range 41.24 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer CSI Solar Co Ltd CS3L-375P rates 375.0 W.

Where Does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG Fall Across Listed CEC Models?

Distribution marker showing HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG (375.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHYUNDAI ENERGY SOL: 375.0 W

What Dataset Percentiles Define HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG?

Dataset percentiles tracking HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG power output, thermal retention ratio, and aperture efficiency against 21,677 models.

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG Engineering BenchmarksPercentile comparison of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention93.6%Module Efficiency20.59%

What Do the Dataset Ranks Show for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG?

Benchmark highlights for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,187

20.59% Aperture Efficiency

Power density 205.8 W/m2 (0.68 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.21 V at -10 C (587.7 V string) and 46.34 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 40.1 m2 (431 sq ft) producing 7,720 W PTC; NEC 690.8 OCPD floor is 17.66 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.24 * (1 + (-0.275/100) * (-10 - 25)) = 45.21 V | OCPD = 1.56 * 11.32 = 17.66 A

Inputs from CEC Modules.csv for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG: Voc=41.24 V, beta_Voc=-0.275%/C, Isc=11.32 A, STC=375.0 W, Area=1.822 m2.

Result: 13 panels max on 600 V (587.7 V); 22 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG?

Official CEC datasheet figures for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 350.9 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.24 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.32 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.59 V / 10.84 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.59% (1.822 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 314 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 431 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 530 sq ft $2,533 $4,283

How Many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG (45.21 V at 14 F).

Computed from Voc=41.24V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.34 V 12 panels 556.1 V 21 panels
-10 C (14 F) 45.21 V 13 panels 587.7 V 22 panels
0 C (32 F) 44.08 V 13 panels 573.0 V 22 panels
25 C (77 F STC) 41.24 V 14 panels 577.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG?

Competing CEC solar panels closest to HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3L-375P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W Tie (0 W) 41.2 V 20.95% 92.5%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 21.07% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 20.72% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 20.49% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG?

Evaluate HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG (375.0 W STC, 41.24 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG reaches 46.34 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
  • 2026 tax credit baseline: cash residential installs of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3L-375P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG by HYUNDAI ENERGY SOLUTIONS CO LTD grounded in CEC test data and NEC 690.7/690.8 limits.

How many HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG panels fit on a 600 V winter solar string?

At -10 C (14 F), HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG cold Voc rises from 41.24 V to 45.21 V (beta_Voc -0.275%/C), capping a 600 V string at 13 panels (587.7 V).

How much roof area does an 8 kW array of HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG need?

An 8 kW DC system uses 22 HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG modules (8,250 W STC / 7,720 W PTC), covering roughly 431 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG compare against CSI Solar Co Ltd CS3L-375P?

HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG outputs 375.0 W STC (41.24 V Voc, rank #11,367 of 21,677), while CSI Solar Co Ltd CS3L-375P delivers 375.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.