Skip to main content
WireAndSun
Calculators
CEC PV Module

Greenlite Solar Canada GLS-200 — CEC Solar Module Specifications

Manufacturer: Greenlite Solar Canada Registry: CEC Verified Engineering Specification

Greenlite Solar Canada GLS-200 is a 200.0 W STC (180.0 W PTC) Multi-c-Si solar module ranking #21,027 of 21,677 CEC listings (below all-CEC median; higher than 2.7% of peers). It delivers 13.71% efficiency, 33.37 V Voc at 25 C, and 36.87 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
200.0 W
PTC Wattage
180.0 W
Voc @ 25C
33.37 V
Efficiency
13.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Greenlite Solar Canada GLS-200 Compare Against Peer CEC Listings?

Engineering position of Greenlite Solar Canada GLS-200 (200.0 W STC) vs. APOS Energy AP205 across 1,407 CEC Multi-c-Si solar modules.

Built with 54 Multi-c-Si cells, Greenlite Solar Canada GLS-200 pairs typical 90.0% PTC-to-STC thermal output (180.0 W real-world rating) with 33.37 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,200 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer APOS Energy AP205 offers a 205.0 W alternative.

Where Does Greenlite Solar Canada GLS-200 Fall Across Listed CEC Models?

Plots Greenlite Solar Canada GLS-200 at 200.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Greenlite Solar Canada GLS-200 (200.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGreenlite Solar Ca: 200.0 W

What Dataset Percentiles Define Greenlite Solar Canada GLS-200?

Benchmarks Greenlite Solar Canada GLS-200 on STC wattage, thermal PTC/STC retention, and 13.71 aperture conversion efficiency against CEC peers.

Greenlite Solar Canada GLS-200 Engineering BenchmarksPercentile comparison of Greenlite Solar Canada GLS-200 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage200.0 WPTC/STC Retention90.0%Module Efficiency13.71%

What Do the Dataset Ranks Show for Greenlite Solar Canada GLS-200?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Greenlite Solar Canada GLS-200 by Greenlite Solar Canada.

Rank #21,027 / 21,677

200.0 W STC · Higher Than 2.7%

200.0 W STC (-185.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,095

13.71% Aperture Efficiency

Power density 137.1 W/m2 (6.20 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.87 V at -10 C (589.9 V string) and 37.87 V at -20 C (15 max).

8 kW Reference Array

40 Panels = 8,000 W STC

Occupies 58.4 m2 (628 sq ft) producing 7,200 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.37 * (1 + (-0.3/100) * (-10 - 25)) = 36.87 V | OCPD = 1.56 * 7.95 = 12.4 A

Inputs from CEC Modules.csv for Greenlite Solar Canada GLS-200: Voc=33.37 V, beta_Voc=-0.3%/C, Isc=7.95 A, STC=200.0 W, Area=1.459 m2.

Result: 16 panels max on 600 V (589.9 V); 40 panels for 8 kW (628 sq ft).

What Are the Published CEC Specifications for Greenlite Solar Canada GLS-200?

Laboratory test ratings recorded for Greenlite Solar Canada GLS-200 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Greenlite Solar Canada GLS-200.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 200.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 180.0 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.37 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 7.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 27.54 V / 7.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.71% (1.459 m2) Array roof footprint density
Cell Count & Technology 54 cells (Multi-c-Si) Monofacial backsheet

How Many Greenlite Solar Canada GLS-200 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (628 sq ft at 8 kW), and estimated Year-1 electric bill offset for Greenlite Solar Canada GLS-200.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 30 6.0 kW 471 sq ft $1,502 $2,539
8 kW Class 40 8.0 kW 628 sq ft $2,002 $3,386
10 kW Class 50 10.0 kW 785 sq ft $2,503 $4,232

How Many Greenlite Solar Canada GLS-200 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Greenlite Solar Canada GLS-200 (beta_Voc -0.3%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=33.37V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 37.87 V 15 panels 568.0 V 26 panels
-10 C (14 F) 36.87 V 16 panels 589.9 V 27 panels
0 C (32 F) 35.87 V 16 panels 573.9 V 27 panels
25 C (77 F STC) 33.37 V 17 panels 567.3 V 29 panels

Which Cross-Brand Solar Modules Compare Closest to Greenlite Solar Canada GLS-200?

Closest cross-brand CEC competitors to Greenlite Solar Canada GLS-200 matched near 200.0 W STC and 33.37 V Voc, led by APOS Energy AP205.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
APOS Energy AP205
APOS Energy
205.0 W +5.0 W 33.48 V 13.67% 88.9%
Guangdong Golden Glass Technologies GG205M2-27/1482x992
Guangdong Golden Glass Technologies
205.0 W +5.0 W 33.2 V 13.94% 89.9%
Gintung Energy ASEC-205G6M
Gintung Energy
205.0 W +5.0 W 33.58 V 14.57% 88.5%
Hanwha Qcells (Qidong) Co Ltd SF190-27-M205
Hanwha Qcells (Qidong) Co Ltd
205.0 W +5.0 W 33.1 V 13.72% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Greenlite Solar Canada GLS-200?

Evaluate Greenlite Solar Canada GLS-200 (200.0 W STC, 33.37 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Greenlite Solar Canada GLS-200 reaches 37.87 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 40 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (628 sq ft).
  • 2026 tax credit baseline: cash residential installs of Greenlite Solar Canada GLS-200 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Greenlite Solar Canada GLS-200 8 kW Residential Fit

Needs 40 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare APOS Energy AP205.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 180.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Greenlite Solar Canada GLS-200 by Greenlite Solar Canada grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Greenlite Solar Canada GLS-200?

Multiplying Greenlite Solar Canada GLS-200's 7.95 A short-circuit current by 1.56 equals 12.4 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Greenlite Solar Canada GLS-200 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 36.87 V cold Voc at 14 F and handles 7.95 A Isc; string inverters cap Greenlite Solar Canada GLS-200 at 16 panels on 600 V.

Is Greenlite Solar Canada GLS-200 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Greenlite Solar Canada GLS-200 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.