Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy GTEC-260G6M6A — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy GTEC-260G6M6A is a 260.0 W STC (229.1 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.14% efficiency, 37.78 V Voc at 25 C, and 42.32 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
229.1 W
Voc @ 25C
37.78 V
Efficiency
16.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy GTEC-260G6M6A Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy GTEC-260G6M6A handles rooftop heat (229.1 W PTC), 8 kW sizing, and cold winter string voltage.

Gintung Energy builds the Gintung Energy GTEC-260G6M6A (Multi-c-Si) as a compact residential or specialty off-grid module delivering 161.4 W/m2 (3.77 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6M610T260 (260.0 W), this model holds typical 88.1% PTC-to-STC thermal output (229.1 W real-world rating). Lower 37.78 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.07 A overcurrent floor served by a 15 A breaker.

Where Does Gintung Energy GTEC-260G6M6A Fall Across Listed CEC Models?

Where Gintung Energy GTEC-260G6M6A (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy GTEC-260G6M6A (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy GTE: 260.0 W

What Dataset Percentiles Define Gintung Energy GTEC-260G6M6A?

Percentile placement of Gintung Energy GTEC-260G6M6A across power density (161.4 W/m2), thermal retention, and nameplate STC wattage.

Gintung Energy GTEC-260G6M6A Engineering BenchmarksPercentile comparison of Gintung Energy GTEC-260G6M6A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention88.1%Module Efficiency16.14%

What Do the Dataset Ranks Show for Gintung Energy GTEC-260G6M6A?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-260G6M6A specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,936

16.14% Aperture Efficiency

Power density 161.4 W/m2 (3.77 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.32 V at -10 C (592.5 V string) and 43.61 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 49.9 m2 (538 sq ft) producing 7,102 W PTC; NEC 690.8 OCPD floor is 14.07 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.78 * (1 + (-0.343/100) * (-10 - 25)) = 42.32 V | OCPD = 1.56 * 9.02 = 14.07 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-260G6M6A: Voc=37.78 V, beta_Voc=-0.343%/C, Isc=9.02 A, STC=260.0 W, Area=1.611 m2.

Result: 14 panels max on 600 V (592.5 V); 31 panels for 8 kW (538 sq ft).

What Are the Published CEC Specifications for Gintung Energy GTEC-260G6M6A?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-260G6M6A.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-260G6M6A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 229.1 W (88.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.78 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.02 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.02 V / 8.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.14% (1.611 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Gintung Energy GTEC-260G6M6A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-260G6M6A (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 416 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 538 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 676 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-260G6M6A architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Gintung Energy GTEC-260G6M6A wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy GTEC-250G6M6A 250.0 W 220.0 W 37.43 V 29.68 V 15.52%
Gintung Energy GTEC-255G6M6A 255.0 W 224.6 W 37.6 V 29.86 V 15.83%
Gintung Energy GTEC-260G6M6A 260.0 W 229.1 W 37.78 V 30.02 V 16.14%
Gintung Energy GTEC-265G6M6A 265.0 W 233.7 W 37.91 V 30.18 V 16.45%
Gintung Energy GTEC-270G6M6A 270.0 W 238.3 W 38.03 V 30.34 V 16.76%

How Many Gintung Energy GTEC-260G6M6A Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy GTEC-260G6M6A from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.78V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.61 V 13 panels 566.9 V 22 panels
-10 C (14 F) 42.32 V 14 panels 592.5 V 23 panels
0 C (32 F) 41.02 V 14 panels 574.3 V 24 panels
25 C (77 F STC) 37.78 V 15 panels 566.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-260G6M6A?

Alternative CEC solar modules from competing brands near Gintung Energy GTEC-260G6M6A (260.0 W), including Auxin Solar AXN6M610T260. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M610T260
Auxin Solar
260.0 W Tie (0 W) 37.8 V 15.87% 89.6%
CSI Solar Co Ltd CS6P-260M
CSI Solar Co Ltd
260.0 W Tie (0 W) 37.8 V 16.79% 91.3%
CSI Solar Co Ltd CS6P-260MX
CSI Solar Co Ltd
260.0 W Tie (0 W) 37.8 V 16.79% 90.7%
AXITEC AC-260M/156-60S
AXITEC
260.0 W Tie (0 W) 37.73 V 16.02% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-260G6M6A?

Evaluate Gintung Energy GTEC-260G6M6A (260.0 W STC, 37.78 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-260G6M6A reaches 43.61 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 538 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (538 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-260G6M6A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy GTEC-260G6M6A 8 kW Residential Fit

Needs 31 modules (538 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610T260.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-260G6M6A by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-260G6M6A?

Multiplying Gintung Energy GTEC-260G6M6A's 9.02 A short-circuit current by 1.56 equals 14.07 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Gintung Energy GTEC-260G6M6A pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.32 V cold Voc at 14 F and handles 9.02 A Isc; string inverters cap Gintung Energy GTEC-260G6M6A at 14 panels on 600 V.

Is Gintung Energy GTEC-260G6M6A eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-260G6M6A rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.