GCL System Integration Technology Co Ltd GCL-P6/72H355 is a 355.0 W STC (325.9 W PTC) Multi-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 18.3% efficiency, 47.9 V Voc at 25 C, and 52.73 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 355.0 W
- PTC Wattage
- 325.9 W
- Voc @ 25C
- 47.9 V
- Efficiency
- 18.3%
How Does GCL System Integration Technology Co Ltd GCL-P6/72H355 Compare Against Peer CEC Listings?
Solar engineering breakdown for GCL System Integration Technology Co Ltd GCL-P6/72H355: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 355.0 W STC and 325.9 W PTC, GCL System Integration Technology Co Ltd GCL-P6/72H355 sits -30.0 W vs all-CEC median (below all-CEC median; higher than 39.9% of peers) among 21,677 listed modules. Power density reaches 183.0 W/m2 (1.61 percentage points below 19.91% CEC median). Mid-range 47.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Bluesun Solar Energy Tech CoLtd BSM355P-72 rates 355.0 W.
Where Does GCL System Integration Technology Co Ltd GCL-P6/72H355 Fall Across Listed CEC Models?
Distribution marker showing GCL System Integration Technology Co Ltd GCL-P6/72H355 (355.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-P6/72H355?
Dataset percentiles tracking GCL System Integration Technology Co Ltd GCL-P6/72H355 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-P6/72H355?
Benchmark highlights for GCL System Integration Technology Co Ltd GCL-P6/72H355 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
355.0 W STC · Higher Than 39.9%
355.0 W STC (-30.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
18.3% Aperture Efficiency
Power density 183.0 W/m2 (1.61 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.73 V at -10 C (580.0 V string) and 54.11 V at -20 C (11 max).
23 Panels = 8,165 W STC
Occupies 44.6 m2 (480 sq ft) producing 7,496 W PTC; NEC 690.8 OCPD floor is 15.19 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.9 * (1 + (-0.288/100) * (-10 - 25)) = 52.73 V | OCPD = 1.56 * 9.74 = 15.19 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-P6/72H355: Voc=47.9 V, beta_Voc=-0.288%/C, Isc=9.74 A, STC=355.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (580.0 V); 23 panels for 8 kW (480 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-P6/72H355?
Official CEC datasheet figures for GCL System Integration Technology Co Ltd GCL-P6/72H355 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 355.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 325.9 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.49 V / 8.99 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.288 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.3% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-P6/72H355 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many GCL System Integration Technology Co Ltd GCL-P6/72H355 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.04 kW | 355 sq ft | $1,512 | $2,556 |
| 8 kW Class | 23 | 8.16 kW | 480 sq ft | $2,042 | $3,454 |
| 10 kW Class | 29 | 10.29 kW | 606 sq ft | $2,575 | $4,355 |
Which Sibling Wattage & Trim Variants Belong to This GCL System Integration Technology Co Ltd Series?
Consolidated GCL System Integration Technology Co Ltd wattage variants sharing the GCL System Integration Technology Co Ltd GCL-P6/72H355 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/72H350 | 350.0 W | 321.2 W | 47.6 V | 39.2 V | 18.04% |
| GCL System Integration Technology Co Ltd GCL-P6/72H355 | 355.0 W | 325.9 W | 47.9 V | 39.49 V | 18.3% |
| GCL System Integration Technology Co Ltd GCL-P6/72H360 | 360.0 W | 330.6 W | 48.2 V | 39.78 V | 18.56% |
How Many GCL System Integration Technology Co Ltd GCL-P6/72H355 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on GCL System Integration Technology Co Ltd GCL-P6/72H355 (52.73 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.11 V | 11 panels | 595.2 V | 18 panels |
| -10 C (14 F) | 52.73 V | 11 panels | 580.0 V | 18 panels |
| 0 C (32 F) | 51.35 V | 11 panels | 564.9 V | 19 panels |
| 25 C (77 F STC) | 47.9 V | 12 panels | 574.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-P6/72H355?
Competing CEC solar panels closest to GCL System Integration Technology Co Ltd GCL-P6/72H355 in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM355P-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM355P-72 Bluesun Solar Energy Tech CoLtd |
355.0 W | Tie (0 W) | 47.52 V | 18.32% | 91.6% |
| AXITEC AC-355M/156-72S AXITEC |
355.0 W | Tie (0 W) | 47.4 V | 18.3% | 91.5% |
| Boviet Solar Technology Co Ltd BVM6612P-355 Boviet Solar Technology Co Ltd |
355.0 W | Tie (0 W) | 47.3 V | 18.3% | 92.6% |
| CertainTeed CT355M00-01 CertainTeed |
355.0 W | Tie (0 W) | 47.3 V | 19.61% | 92.0% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-P6/72H355?
Evaluate GCL System Integration Technology Co Ltd GCL-P6/72H355 (355.0 W STC, 47.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-P6/72H355 reaches 54.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 480 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (480 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-P6/72H355 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-P6/72H355 8 kW Residential Fit
Needs 23 modules (480 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM355P-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 325.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-P6/72H355 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many GCL System Integration Technology Co Ltd GCL-P6/72H355 panels fit on a 600 V winter solar string?
At -10 C (14 F), GCL System Integration Technology Co Ltd GCL-P6/72H355 cold Voc rises from 47.9 V to 52.73 V (beta_Voc -0.288%/C), capping a 600 V string at 11 panels (580.0 V).
How much roof area does an 8 kW array of GCL System Integration Technology Co Ltd GCL-P6/72H355 need?
An 8 kW DC system uses 23 GCL System Integration Technology Co Ltd GCL-P6/72H355 modules (8,165 W STC / 7,496 W PTC), covering roughly 480 sq ft and saving ~$2,042/yr at 18.54 c/kWh.
How does GCL System Integration Technology Co Ltd GCL-P6/72H355 compare against Bluesun Solar Energy Tech CoLtd BSM355P-72?
GCL System Integration Technology Co Ltd GCL-P6/72H355 outputs 355.0 W STC (47.9 V Voc, rank #12,724 of 21,677), while Bluesun Solar Energy Tech CoLtd BSM355P-72 delivers 355.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)