GCL System Integration Technology Co Ltd GCL-M6/72H385 is a 385.0 W STC (358.2 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.85% efficiency, 48.4 V Voc at 25 C, and 53.01 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 385.0 W
- PTC Wattage
- 358.2 W
- Voc @ 25C
- 48.4 V
- Efficiency
- 19.85%
How Does GCL System Integration Technology Co Ltd GCL-M6/72H385 Compare Against Peer CEC Listings?
Solar engineering breakdown for GCL System Integration Technology Co Ltd GCL-M6/72H385: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 385.0 W STC and 358.2 W PTC, GCL System Integration Technology Co Ltd GCL-M6/72H385 sits equal to all-CEC median (at all-CEC median; higher than 49.1% of peers) among 21,677 listed modules. Power density reaches 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). Higher 48.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-385L-H rates 385.0 W.
Where Does GCL System Integration Technology Co Ltd GCL-M6/72H385 Fall Across Listed CEC Models?
Distribution marker showing GCL System Integration Technology Co Ltd GCL-M6/72H385 (385.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/72H385?
Dataset percentiles tracking GCL System Integration Technology Co Ltd GCL-M6/72H385 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/72H385?
Benchmark highlights for GCL System Integration Technology Co Ltd GCL-M6/72H385 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
385.0 W STC · Higher Than 49.1%
385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.
19.85% Aperture Efficiency
Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.01 V at -10 C (583.1 V string) and 54.32 V at -20 C (11 max).
21 Panels = 8,085 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,522 W PTC; NEC 690.8 OCPD floor is 15.93 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.4 * (1 + (-0.272/100) * (-10 - 25)) = 53.01 V | OCPD = 1.56 * 10.21 = 15.93 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/72H385: Voc=48.4 V, beta_Voc=-0.272%/C, Isc=10.21 A, STC=385.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (583.1 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/72H385?
Official CEC datasheet figures for GCL System Integration Technology Co Ltd GCL-M6/72H385 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 358.2 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.21 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.98 V / 9.63 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.85% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-M6/72H385 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many GCL System Integration Technology Co Ltd GCL-M6/72H385 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.16 kW | 334 sq ft | $1,542 | $2,607 |
| 8 kW Class | 21 | 8.09 kW | 439 sq ft | $2,025 | $3,424 |
| 10 kW Class | 26 | 10.01 kW | 543 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This GCL System Integration Technology Co Ltd Series?
Consolidated GCL System Integration Technology Co Ltd wattage variants sharing the GCL System Integration Technology Co Ltd GCL-M6/72H385 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/72H375 | 375.0 W | 349.8 W | 48.0 V | 39.6 V | 18.94% |
| GCL System Integration Technology Co Ltd GCL-M6/72H380 | 380.0 W | 353.4 W | 48.2 V | 39.8 V | 19.59% |
| GCL System Integration Technology Co Ltd GCL-M6/72H385 | 385.0 W | 358.2 W | 48.4 V | 39.98 V | 19.85% |
| GCL System Integration Technology Co Ltd GCL-M6/72H390 | 390.0 W | 363.0 W | 48.6 V | 40.17 V | 20.1% |
| GCL System Integration Technology Co Ltd GCL-M6/72H395 | 395.0 W | 367.7 W | 48.8 V | 40.35 V | 20.36% |
How Many GCL System Integration Technology Co Ltd GCL-M6/72H385 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on GCL System Integration Technology Co Ltd GCL-M6/72H385 (53.01 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.32 V | 11 panels | 597.5 V | 18 panels |
| -10 C (14 F) | 53.01 V | 11 panels | 583.1 V | 18 panels |
| 0 C (32 F) | 51.69 V | 11 panels | 568.6 V | 19 panels |
| 25 C (77 F STC) | 48.4 V | 12 panels | 580.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/72H385?
Competing CEC solar panels closest to GCL System Integration Technology Co Ltd GCL-M6/72H385 in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-385L-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-385L-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 18.97% | 93.5% |
| Boviet Solar Technology Co Ltd BVM6612M-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/72H385?
Evaluate GCL System Integration Technology Co Ltd GCL-M6/72H385 (385.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/72H385 reaches 54.32 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (439 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/72H385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-M6/72H385 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-385L-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 358.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-M6/72H385 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many GCL System Integration Technology Co Ltd GCL-M6/72H385 panels fit on a 600 V winter solar string?
At -10 C (14 F), GCL System Integration Technology Co Ltd GCL-M6/72H385 cold Voc rises from 48.4 V to 53.01 V (beta_Voc -0.272%/C), capping a 600 V string at 11 panels (583.1 V).
How much roof area does an 8 kW array of GCL System Integration Technology Co Ltd GCL-M6/72H385 need?
An 8 kW DC system uses 21 GCL System Integration Technology Co Ltd GCL-M6/72H385 modules (8,085 W STC / 7,522 W PTC), covering roughly 439 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does GCL System Integration Technology Co Ltd GCL-M6/72H385 compare against Boviet Solar Technology Co Ltd BVM6612M-385L-H?
GCL System Integration Technology Co Ltd GCL-M6/72H385 outputs 385.0 W STC (48.4 V Voc, rank #10,723 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-385L-H delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)