Skip to main content
WireAndSun
Calculators
CEC PV Module

Gautam Solar Pvt Ltd G2X1770N-UHAD — CEC Solar Module Specifications

Manufacturer: Gautam Solar Pvt Ltd Registry: CEC Verified Engineering Specification

Gautam Solar Pvt Ltd G2X1770N-UHAD is a 590.0 W STC (560.1 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 22.96% efficiency, 51.34 V Voc at 25 C, and 55.58 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
590.0 W
PTC Wattage
560.1 W
Voc @ 25C
51.34 V
Efficiency
22.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gautam Solar Pvt Ltd G2X1770N-UHAD Compare Against Peer CEC Listings?

Solar engineering breakdown for Gautam Solar Pvt Ltd G2X1770N-UHAD: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Gautam Solar Pvt Ltd and peers, Gautam Solar Pvt Ltd G2X1770N-UHAD stands 180.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (11 panels) to 10 kW (17 panels) yields $1,624-$2,510/yr in baseline US bill offset. Higher 51.34 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Gautam Solar Pvt Ltd G2X1770N-UHAD Fall Across Listed CEC Models?

Distribution marker showing Gautam Solar Pvt Ltd G2X1770N-UHAD (590.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gautam Solar Pvt Ltd G2X1770N-UHAD (590.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGautam Solar Pvt L: 590.0 W

What Dataset Percentiles Define Gautam Solar Pvt Ltd G2X1770N-UHAD?

Dataset percentiles tracking Gautam Solar Pvt Ltd G2X1770N-UHAD power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Gautam Solar Pvt Ltd G2X1770N-UHAD Engineering BenchmarksPercentile comparison of Gautam Solar Pvt Ltd G2X1770N-UHAD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage590.0 WPTC/STC Retention94.9%Module Efficiency22.96%

What Do the Dataset Ranks Show for Gautam Solar Pvt Ltd G2X1770N-UHAD?

Benchmark highlights for Gautam Solar Pvt Ltd G2X1770N-UHAD covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,597 / 21,677

Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,189

22.96% Aperture Efficiency

Power density 229.6 W/m2 (3.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.58 V at -10 C (555.8 V string) and 56.79 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,260 W STC

Occupies 36.0 m2 (387 sq ft) producing 7,841 W PTC; NEC 690.8 OCPD floor is 22.76 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.34 * (1 + (-0.236/100) * (-10 - 25)) = 55.58 V | OCPD = 1.56 * 14.59 = 22.76 A

Inputs from CEC Modules.csv for Gautam Solar Pvt Ltd G2X1770N-UHAD: Voc=51.34 V, beta_Voc=-0.236%/C, Isc=14.59 A, STC=590.0 W, Area=2.57 m2.

Result: 10 panels max on 600 V (555.8 V); 14 panels for 8 kW (387 sq ft).

What Are the Published CEC Specifications for Gautam Solar Pvt Ltd G2X1770N-UHAD?

Official CEC datasheet figures for Gautam Solar Pvt Ltd G2X1770N-UHAD (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Gautam Solar Pvt Ltd G2X1770N-UHAD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 590.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 560.1 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.34 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.67 V / 13.84 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.96% (2.57 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Gautam Solar Pvt Ltd G2X1770N-UHAD Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gautam Solar Pvt Ltd G2X1770N-UHAD modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.49 kW 304 sq ft $1,624 $2,747
8 kW Class 14 8.26 kW 387 sq ft $2,067 $3,496
10 kW Class 17 10.03 kW 470 sq ft $2,510 $4,245

How Many Gautam Solar Pvt Ltd G2X1770N-UHAD Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gautam Solar Pvt Ltd G2X1770N-UHAD (55.58 V at 14 F).

Computed from Voc=51.34V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.79 V 10 panels 567.9 V 17 panels
-10 C (14 F) 55.58 V 10 panels 555.8 V 17 panels
0 C (32 F) 54.37 V 11 panels 598.1 V 18 panels
25 C (77 F STC) 51.34 V 11 panels 564.7 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Gautam Solar Pvt Ltd G2X1770N-UHAD?

Competing CEC solar panels closest to Gautam Solar Pvt Ltd G2X1770N-UHAD in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS61-72TB-590H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS61-72TB-590H
CSI Solar Co Ltd
590.0 W Tie (0 W) 51.4 V 22.52% 95.2%
Aptos Solar Technology LLC DNA-144-BFN10-590W-DG
Aptos Solar Technology LLC
590.0 W Tie (0 W) 52.4 V 22.87% 95.0%
BLUESUN GROUP LIMITED BSM590M10-72HNH
BLUESUN GROUP LIMITED
590.0 W Tie (0 W) 52.4 V 22.87% 95.0%
Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-595
Chint New Energy Technology Co Ltd
595.0 W +5.0 W 51.2 V 22.04% 94.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gautam Solar Pvt Ltd G2X1770N-UHAD?

Evaluate Gautam Solar Pvt Ltd G2X1770N-UHAD (590.0 W STC, 51.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gautam Solar Pvt Ltd G2X1770N-UHAD reaches 56.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 387 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Gautam Solar Pvt Ltd G2X1770N-UHAD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gautam Solar Pvt Ltd G2X1770N-UHAD 8 kW Residential Fit

Needs 14 modules (387 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS61-72TB-590H.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 560.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gautam Solar Pvt Ltd G2X1770N-UHAD by Gautam Solar Pvt Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Gautam Solar Pvt Ltd G2X1770N-UHAD?

Multiplying Gautam Solar Pvt Ltd G2X1770N-UHAD's 14.59 A short-circuit current by 1.56 equals 22.76 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Gautam Solar Pvt Ltd G2X1770N-UHAD pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.58 V cold Voc at 14 F and handles 14.59 A Isc; string inverters cap Gautam Solar Pvt Ltd G2X1770N-UHAD at 10 panels on 600 V.

Is Gautam Solar Pvt Ltd G2X1770N-UHAD eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gautam Solar Pvt Ltd G2X1770N-UHAD rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.