Gautam Solar Pvt Ltd G2X1770N-UHAD is a 590.0 W STC (560.1 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 22.96% efficiency, 51.34 V Voc at 25 C, and 55.58 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 590.0 W
- PTC Wattage
- 560.1 W
- Voc @ 25C
- 51.34 V
- Efficiency
- 22.96%
How Does Gautam Solar Pvt Ltd G2X1770N-UHAD Compare Against Peer CEC Listings?
Solar engineering breakdown for Gautam Solar Pvt Ltd G2X1770N-UHAD: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Gautam Solar Pvt Ltd and peers, Gautam Solar Pvt Ltd G2X1770N-UHAD stands 180.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (11 panels) to 10 kW (17 panels) yields $1,624-$2,510/yr in baseline US bill offset. Higher 51.34 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Gautam Solar Pvt Ltd G2X1770N-UHAD Fall Across Listed CEC Models?
Distribution marker showing Gautam Solar Pvt Ltd G2X1770N-UHAD (590.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Gautam Solar Pvt Ltd G2X1770N-UHAD?
Dataset percentiles tracking Gautam Solar Pvt Ltd G2X1770N-UHAD power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Gautam Solar Pvt Ltd G2X1770N-UHAD?
Benchmark highlights for Gautam Solar Pvt Ltd G2X1770N-UHAD covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 8.1% STC Output
590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.96% Aperture Efficiency
Power density 229.6 W/m2 (3.05 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.58 V at -10 C (555.8 V string) and 56.79 V at -20 C (10 max).
14 Panels = 8,260 W STC
Occupies 36.0 m2 (387 sq ft) producing 7,841 W PTC; NEC 690.8 OCPD floor is 22.76 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.34 * (1 + (-0.236/100) * (-10 - 25)) = 55.58 V | OCPD = 1.56 * 14.59 = 22.76 A
Inputs from CEC Modules.csv for Gautam Solar Pvt Ltd G2X1770N-UHAD: Voc=51.34 V, beta_Voc=-0.236%/C, Isc=14.59 A, STC=590.0 W, Area=2.57 m2.
Result: 10 panels max on 600 V (555.8 V); 14 panels for 8 kW (387 sq ft).
What Are the Published CEC Specifications for Gautam Solar Pvt Ltd G2X1770N-UHAD?
Official CEC datasheet figures for Gautam Solar Pvt Ltd G2X1770N-UHAD (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 590.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 560.1 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.34 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.67 V / 13.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.96% (2.57 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Gautam Solar Pvt Ltd G2X1770N-UHAD Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Gautam Solar Pvt Ltd G2X1770N-UHAD modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.49 kW | 304 sq ft | $1,624 | $2,747 |
| 8 kW Class | 14 | 8.26 kW | 387 sq ft | $2,067 | $3,496 |
| 10 kW Class | 17 | 10.03 kW | 470 sq ft | $2,510 | $4,245 |
How Many Gautam Solar Pvt Ltd G2X1770N-UHAD Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Gautam Solar Pvt Ltd G2X1770N-UHAD (55.58 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.79 V | 10 panels | 567.9 V | 17 panels |
| -10 C (14 F) | 55.58 V | 10 panels | 555.8 V | 17 panels |
| 0 C (32 F) | 54.37 V | 11 panels | 598.1 V | 18 panels |
| 25 C (77 F STC) | 51.34 V | 11 panels | 564.7 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Gautam Solar Pvt Ltd G2X1770N-UHAD?
Competing CEC solar panels closest to Gautam Solar Pvt Ltd G2X1770N-UHAD in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS61-72TB-590H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS61-72TB-590H CSI Solar Co Ltd |
590.0 W | Tie (0 W) | 51.4 V | 22.52% | 95.2% |
| Aptos Solar Technology LLC DNA-144-BFN10-590W-DG Aptos Solar Technology LLC |
590.0 W | Tie (0 W) | 52.4 V | 22.87% | 95.0% |
| BLUESUN GROUP LIMITED BSM590M10-72HNH BLUESUN GROUP LIMITED |
590.0 W | Tie (0 W) | 52.4 V | 22.87% | 95.0% |
| Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-595 Chint New Energy Technology Co Ltd |
595.0 W | +5.0 W | 51.2 V | 22.04% | 94.7% |
What Are the Design Limits and Best-Fit Uses for Gautam Solar Pvt Ltd G2X1770N-UHAD?
Evaluate Gautam Solar Pvt Ltd G2X1770N-UHAD (590.0 W STC, 51.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gautam Solar Pvt Ltd G2X1770N-UHAD reaches 56.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 387 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Gautam Solar Pvt Ltd G2X1770N-UHAD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gautam Solar Pvt Ltd G2X1770N-UHAD 8 kW Residential Fit
Needs 14 modules (387 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS61-72TB-590H.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 560.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gautam Solar Pvt Ltd G2X1770N-UHAD by Gautam Solar Pvt Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Gautam Solar Pvt Ltd G2X1770N-UHAD?
Multiplying Gautam Solar Pvt Ltd G2X1770N-UHAD's 14.59 A short-circuit current by 1.56 equals 22.76 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Gautam Solar Pvt Ltd G2X1770N-UHAD pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 55.58 V cold Voc at 14 F and handles 14.59 A Isc; string inverters cap Gautam Solar Pvt Ltd G2X1770N-UHAD at 10 panels on 600 V.
Is Gautam Solar Pvt Ltd G2X1770N-UHAD eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gautam Solar Pvt Ltd G2X1770N-UHAD rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)