Skip to main content
WireAndSun
Calculators
CEC PV Module

ES Foundry Corp ES-DP8-H72L-520W — CEC Solar Module Specifications

Manufacturer: ES Foundry Corp Registry: CEC Verified Engineering Specification

ES Foundry Corp ES-DP8-H72L-520W is a 520.0 W STC (484.4 W PTC) Mono-c-Si solar module ranking #4,199 of 21,677 CEC listings (top 19.9%; higher than 80.1% of peers). It delivers 20.88% efficiency, 48.9 V Voc at 25 C, and 53.33 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
520.0 W
PTC Wattage
484.4 W
Voc @ 25C
48.9 V
Efficiency
20.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ES Foundry Corp ES-DP8-H72L-520W Compare Against Peer CEC Listings?

Engineering position of ES Foundry Corp ES-DP8-H72L-520W (520.0 W STC) vs. Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520 across 5,889 CEC Mono-c-Si solar modules.

Ranking #4,199 across 21,677 CEC solar panels (top 19.9%; higher than 80.1% of peers), ES Foundry Corp ES-DP8-H72L-520W operates as a modern high-density residential and light-commercial module sitting 110.0 W above the 410.0 W Mono-c-Si median. Higher 48.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677), 16 panels occupy 429 sq ft and offset roughly $2,082/yr at average US rates (or $3,521/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does ES Foundry Corp ES-DP8-H72L-520W Fall Across Listed CEC Models?

Plots ES Foundry Corp ES-DP8-H72L-520W at 520.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ES Foundry Corp ES-DP8-H72L-520W (520.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCES Foundry Corp ES: 520.0 W

What Dataset Percentiles Define ES Foundry Corp ES-DP8-H72L-520W?

Benchmarks ES Foundry Corp ES-DP8-H72L-520W on STC wattage, thermal PTC/STC retention, and 20.88 aperture conversion efficiency against CEC peers.

ES Foundry Corp ES-DP8-H72L-520W Engineering BenchmarksPercentile comparison of ES Foundry Corp ES-DP8-H72L-520W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage520.0 WPTC/STC Retention93.2%Module Efficiency20.88%

What Do the Dataset Ranks Show for ES Foundry Corp ES-DP8-H72L-520W?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for ES Foundry Corp ES-DP8-H72L-520W by ES Foundry Corp.

Rank #4,199 / 21,677

Top 19.9% STC Output

520.0 W STC (+135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,925

20.88% Aperture Efficiency

Power density 208.8 W/m2 (0.97 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.33 V at -10 C (586.6 V string) and 54.6 V at -20 C (10 max).

8 kW Reference Array

16 Panels = 8,320 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,750 W PTC; NEC 690.8 OCPD floor is 21.17 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.9 * (1 + (-0.259/100) * (-10 - 25)) = 53.33 V | OCPD = 1.56 * 13.57 = 21.17 A

Inputs from CEC Modules.csv for ES Foundry Corp ES-DP8-H72L-520W: Voc=48.9 V, beta_Voc=-0.259%/C, Isc=13.57 A, STC=520.0 W, Area=2.49 m2.

Result: 11 panels max on 600 V (586.6 V); 16 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for ES Foundry Corp ES-DP8-H72L-520W?

Laboratory test ratings recorded for ES Foundry Corp ES-DP8-H72L-520W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for ES Foundry Corp ES-DP8-H72L-520W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 520.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 484.4 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.1 V / 12.67 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.88% (2.49 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many ES Foundry Corp ES-DP8-H72L-520W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (429 sq ft at 8 kW), and estimated Year-1 electric bill offset for ES Foundry Corp ES-DP8-H72L-520W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.24 kW 322 sq ft $1,562 $2,641
8 kW Class 16 8.32 kW 429 sq ft $2,082 $3,521
10 kW Class 20 10.4 kW 536 sq ft $2,603 $4,402

How Many ES Foundry Corp ES-DP8-H72L-520W Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for ES Foundry Corp ES-DP8-H72L-520W (beta_Voc -0.259%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.9V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.6 V 10 panels 546.0 V 18 panels
-10 C (14 F) 53.33 V 11 panels 586.6 V 18 panels
0 C (32 F) 52.07 V 11 panels 572.8 V 19 panels
25 C (77 F STC) 48.9 V 12 panels 586.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to ES Foundry Corp ES-DP8-H72L-520W?

Closest cross-brand CEC competitors to ES Foundry Corp ES-DP8-H72L-520W matched near 520.0 W STC and 48.9 V Voc, led by Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520
Jiangsu Green Energy Power Technology Co Ltd
520.0 W Tie (0 W) 48.9 V 20.63% 93.8%
Bila Solar Inc AA520US-6x24GG
Bila Solar Inc
520.0 W Tie (0 W) 49.0 V 20.72% 92.7%
HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI
HYUNDAI ENERGY SOLUTIONS CO LTD
520.0 W Tie (0 W) 49.0 V 20.23% 93.9%
Heliene 144HC-520 M10 Bifacial
Heliene
520.0 W Tie (0 W) 48.73 V 20.72% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ES Foundry Corp ES-DP8-H72L-520W?

Evaluate ES Foundry Corp ES-DP8-H72L-520W (520.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ES Foundry Corp ES-DP8-H72L-520W reaches 54.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 16 panels for an 8 kW build require 429 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (429 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of ES Foundry Corp ES-DP8-H72L-520W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ES Foundry Corp ES-DP8-H72L-520W 8 kW Residential Fit

Needs 16 modules (429 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 484.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ES Foundry Corp ES-DP8-H72L-520W by ES Foundry Corp grounded in CEC test data and NEC 690.7/690.8 limits.

How many ES Foundry Corp ES-DP8-H72L-520W panels fit on a 600 V winter solar string?

At -10 C (14 F), ES Foundry Corp ES-DP8-H72L-520W cold Voc rises from 48.9 V to 53.33 V (beta_Voc -0.259%/C), capping a 600 V string at 11 panels (586.6 V).

How much roof area does an 8 kW array of ES Foundry Corp ES-DP8-H72L-520W need?

An 8 kW DC system uses 16 ES Foundry Corp ES-DP8-H72L-520W modules (8,320 W STC / 7,750 W PTC), covering roughly 429 sq ft and saving ~$2,082/yr at 18.54 c/kWh.

How does ES Foundry Corp ES-DP8-H72L-520W compare against Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520?

ES Foundry Corp ES-DP8-H72L-520W outputs 520.0 W STC (48.9 V Voc, rank #4,199 of 21,677), while Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520 delivers 520.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.