Energy America LLC EA-ZLK7-SHDB108-410/M is a 410.0 W STC (381.2 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.5 V Voc at 25 C, and 41.0 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 381.2 W
- Voc @ 25C
- 37.5 V
- Efficiency
- 21.13%
How Does Energy America LLC EA-ZLK7-SHDB108-410/M Compare Against Peer CEC Listings?
Engineering position of Energy America LLC EA-ZLK7-SHDB108-410/M (410.0 W STC) vs. ASTORIOS Holding Inc ASTR108BDG-410W-US across 5,889 CEC Mono-c-Si solar modules.
Built with 54 Mono-c-Si cells, Energy America LLC EA-ZLK7-SHDB108-410/M pairs strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677) with 37.5 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,624 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer ASTORIOS Holding Inc ASTR108BDG-410W-US offers a 410.0 W alternative.
Where Does Energy America LLC EA-ZLK7-SHDB108-410/M Fall Across Listed CEC Models?
Plots Energy America LLC EA-ZLK7-SHDB108-410/M at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Energy America LLC EA-ZLK7-SHDB108-410/M?
Benchmarks Energy America LLC EA-ZLK7-SHDB108-410/M on STC wattage, thermal PTC/STC retention, and 21.13 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Energy America LLC EA-ZLK7-SHDB108-410/M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Energy America LLC EA-ZLK7-SHDB108-410/M by Energy America LLC.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.13% Aperture Efficiency
Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.0 V at -10 C (574.0 V string) and 42.01 V at -20 C (14 max).
20 Panels = 8,200 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,624 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.5 * (1 + (-0.267/100) * (-10 - 25)) = 41.0 V | OCPD = 1.56 * 13.86 = 21.62 A
Inputs from CEC Modules.csv for Energy America LLC EA-ZLK7-SHDB108-410/M: Voc=37.5 V, beta_Voc=-0.267%/C, Isc=13.86 A, STC=410.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (574.0 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Energy America LLC EA-ZLK7-SHDB108-410/M?
Laboratory test ratings recorded for Energy America LLC EA-ZLK7-SHDB108-410/M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 381.2 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.3 V / 13.1 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.13% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Energy America LLC EA-ZLK7-SHDB108-410/M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for Energy America LLC EA-ZLK7-SHDB108-410/M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 313 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 418 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 522 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This Energy America LLC Series?
Sibling wattage bins and frame colors grouped with Energy America LLC EA-ZLK7-SHDB108-410/M under Energy America LLC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Energy America LLC EA-ZLK7-SHDB108-400/M | 400.0 W | 371.6 W | 37.1 V | 30.9 V | 20.62% |
| Energy America LLC EA-ZLK7-SHDB108-405/M | 405.0 W | 376.4 W | 37.3 V | 31.1 V | 20.88% |
| Energy America LLC EA-ZLK7-SHDB108-410/M | 410.0 W | 381.2 W | 37.5 V | 31.3 V | 21.13% |
| Energy America LLC EA-ZLK7-SHDB108-415/M | 415.0 W | 386.0 W | 37.7 V | 31.5 V | 21.39% |
How Many Energy America LLC EA-ZLK7-SHDB108-410/M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Energy America LLC EA-ZLK7-SHDB108-410/M (beta_Voc -0.267%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.01 V | 14 panels | 588.1 V | 23 panels |
| -10 C (14 F) | 41.0 V | 14 panels | 574.0 V | 24 panels |
| 0 C (32 F) | 40.0 V | 15 panels | 600.0 V | 25 panels |
| 25 C (77 F STC) | 37.5 V | 16 panels | 600.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Energy America LLC EA-ZLK7-SHDB108-410/M?
Closest cross-brand CEC competitors to Energy America LLC EA-ZLK7-SHDB108-410/M matched near 410.0 W STC and 37.5 V Voc, led by ASTORIOS Holding Inc ASTR108BDG-410W-US.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ASTORIOS Holding Inc ASTR108BDG-410W-US ASTORIOS Holding Inc |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| AXITEC AC-410MBT/108US AXITEC |
410.0 W | Tie (0 W) | 37.5 V | 21.13% | 93.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-410 Elin Energy (Sirius PV) |
410.0 W | Tie (0 W) | 37.32 V | 21.13% | 94.4% |
| CSI Solar Co Ltd CS6R-410MB CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 38.0 V | 21.69% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Energy America LLC EA-ZLK7-SHDB108-410/M?
Evaluate Energy America LLC EA-ZLK7-SHDB108-410/M (410.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Energy America LLC EA-ZLK7-SHDB108-410/M reaches 42.01 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Energy America LLC EA-ZLK7-SHDB108-410/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Energy America LLC EA-ZLK7-SHDB108-410/M 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ASTORIOS Holding Inc ASTR108BDG-410W-US.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 381.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Energy America LLC EA-ZLK7-SHDB108-410/M by Energy America LLC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Energy America LLC EA-ZLK7-SHDB108-410/M?
Multiplying Energy America LLC EA-ZLK7-SHDB108-410/M's 13.86 A short-circuit current by 1.56 equals 21.62 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Energy America LLC EA-ZLK7-SHDB108-410/M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.0 V cold Voc at 14 F and handles 13.86 A Isc; string inverters cap Energy America LLC EA-ZLK7-SHDB108-410/M at 14 panels on 600 V.
Is Energy America LLC EA-ZLK7-SHDB108-410/M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Energy America LLC EA-ZLK7-SHDB108-410/M rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)