Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS6R-390MB-HL — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS6R-390MB-HL is a 390.0 W STC (366.9 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.63% efficiency, 37.2 V Voc at 25 C, and 40.55 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
390.0 W
PTC Wattage
366.9 W
Voc @ 25C
37.2 V
Efficiency
20.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS6R-390MB-HL Compare Against Peer CEC Listings?

How CSI Solar Co Ltd CSI Solar Co Ltd CS6R-390MB-HL handles rooftop heat (366.9 W PTC), 8 kW sizing, and cold winter string voltage.

CSI Solar Co Ltd builds the CSI Solar Co Ltd CS6R-390MB-HL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 206.3 W/m2 (0.72 percentage points above 19.91% CEC median). Compared against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS (390.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Lower 37.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 20.67 A overcurrent floor served by a 25 A breaker.

Where Does CSI Solar Co Ltd CS6R-390MB-HL Fall Across Listed CEC Models?

Where CSI Solar Co Ltd CS6R-390MB-HL (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS6R-390MB-HL (390.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 390.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS6R-390MB-HL?

Percentile placement of CSI Solar Co Ltd CS6R-390MB-HL across power density (206.3 W/m2), thermal retention, and nameplate STC wattage.

CSI Solar Co Ltd CS6R-390MB-HL Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS6R-390MB-HL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage390.0 WPTC/STC Retention94.1%Module Efficiency20.63%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6R-390MB-HL?

Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS6R-390MB-HL specifications.

Rank #10,321 / 21,677

Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,981

20.63% Aperture Efficiency

Power density 206.3 W/m2 (0.72 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.55 V at -10 C (567.7 V string) and 41.5 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,190 W STC

Occupies 39.7 m2 (427 sq ft) producing 7,705 W PTC; NEC 690.8 OCPD floor is 20.67 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.2 * (1 + (-0.257/100) * (-10 - 25)) = 40.55 V | OCPD = 1.56 * 13.25 = 20.67 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6R-390MB-HL: Voc=37.2 V, beta_Voc=-0.257%/C, Isc=13.25 A, STC=390.0 W, Area=1.89 m2.

Result: 14 panels max on 600 V (567.7 V); 21 panels for 8 kW (427 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS6R-390MB-HL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS6R-390MB-HL.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS6R-390MB-HL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 390.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 366.9 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.25 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.0 V / 12.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.257 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.63% (1.89 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many CSI Solar Co Ltd CS6R-390MB-HL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS6R-390MB-HL (390.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.24 kW 326 sq ft $1,562 $2,641
8 kW Class 21 8.19 kW 427 sq ft $2,050 $3,466
10 kW Class 26 10.14 kW 529 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS6R-390MB-HL architecture.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS6R-390MB-HL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS6R-385MB-HL 385.0 W 362.1 W 37.0 V 30.8 V 20.37%
CSI Solar Co Ltd CS6R-390MB-HL 390.0 W 366.9 W 37.2 V 31.0 V 20.63%
CSI Solar Co Ltd CS6R-395MB-HL 395.0 W 371.7 W 37.4 V 31.2 V 20.9%

How Many CSI Solar Co Ltd CS6R-390MB-HL Modules Fit in a Cold-Weather String?

Maximum series module counts for CSI Solar Co Ltd CS6R-390MB-HL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.2V and beta_Voc=-0.257%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.5 V 14 panels 581.0 V 24 panels
-10 C (14 F) 40.55 V 14 panels 567.7 V 24 panels
0 C (32 F) 39.59 V 15 panels 593.9 V 25 panels
25 C (77 F STC) 37.2 V 16 panels 595.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6R-390MB-HL?

Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS6R-390MB-HL (390.0 W), including ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
390.0 W Tie (0 W) 36.9 V 20.21% 93.3%
Aptos Solar Technology LLC DNA-108-BF10-390W
Aptos Solar Technology LLC
390.0 W Tie (0 W) 36.85 V 20.21% 93.2%
Dehui Solar Power (Vietnam) CoLtd DH-M154T 390W
Dehui Solar Power (Vietnam) CoLtd
390.0 W Tie (0 W) 36.85 V 20.21% 93.2%
ELITE Solar ET-M754BH390TB
ELITE Solar
390.0 W Tie (0 W) 36.85 V 15.23% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6R-390MB-HL?

Evaluate CSI Solar Co Ltd CS6R-390MB-HL (390.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6R-390MB-HL reaches 41.5 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 427 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (427 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6R-390MB-HL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS6R-390MB-HL 8 kW Residential Fit

Needs 21 modules (427 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 366.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS6R-390MB-HL by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS6R-390MB-HL?

Multiplying CSI Solar Co Ltd CS6R-390MB-HL's 13.25 A short-circuit current by 1.56 equals 20.67 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can CSI Solar Co Ltd CS6R-390MB-HL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.55 V cold Voc at 14 F and handles 13.25 A Isc; string inverters cap CSI Solar Co Ltd CS6R-390MB-HL at 14 panels on 600 V.

Is CSI Solar Co Ltd CS6R-390MB-HL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS6R-390MB-HL rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls