Skip to main content
WireAndSun
Calculators
CEC PV Module

CSI Solar Co Ltd CS61-72TB-630H — CEC Solar Module Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd CS61-72TB-630H is a 630.0 W STC (600.8 W PTC) Mono-c-Si solar module ranking #783 of 21,677 CEC listings (top 4.0%; higher than 96.0% of peers). It delivers 24.05% efficiency, 53.0 V Voc at 25 C, and 57.38 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
630.0 W
PTC Wattage
600.8 W
Voc @ 25C
53.0 V
Efficiency
24.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd CS61-72TB-630H Compare Against Peer CEC Listings?

How CSI Solar Co Ltd CSI Solar Co Ltd CS61-72TB-630H handles rooftop heat (600.8 W PTC), 8 kW sizing, and cold winter string voltage.

CSI Solar Co Ltd builds the CSI Solar Co Ltd CS61-72TB-630H (Mono-c-Si) as a large-format commercial and ground-mount module delivering 240.5 W/m2 (4.14 percentage points above 19.91% CEC median). Compared against FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-630 (630.0 W), this model holds strong 95.4% PTC-to-STC heat retention (#141 of 21,677). Higher 53.0 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 23.24 A overcurrent floor served by a 25 A breaker.

Where Does CSI Solar Co Ltd CS61-72TB-630H Fall Across Listed CEC Models?

Where CSI Solar Co Ltd CS61-72TB-630H (630.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where CSI Solar Co Ltd CS61-72TB-630H (630.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCSI Solar Co Ltd C: 630.0 W

What Dataset Percentiles Define CSI Solar Co Ltd CS61-72TB-630H?

Percentile placement of CSI Solar Co Ltd CS61-72TB-630H across power density (240.5 W/m2), thermal retention, and nameplate STC wattage.

CSI Solar Co Ltd CS61-72TB-630H Engineering BenchmarksPercentile comparison of CSI Solar Co Ltd CS61-72TB-630H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage630.0 WPTC/STC Retention95.4%Module Efficiency24.05%

What Do the Dataset Ranks Show for CSI Solar Co Ltd CS61-72TB-630H?

Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS61-72TB-630H specifications.

Rank #783 / 21,677

Top 4.0% STC Output

630.0 W STC (+245.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #208

24.05% Aperture Efficiency

Power density 240.5 W/m2 (4.14 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.38 V at -10 C (573.8 V string) and 58.63 V at -20 C (10 max).

8 kW Reference Array

13 Panels = 8,190 W STC

Occupies 34.1 m2 (367 sq ft) producing 7,810 W PTC; NEC 690.8 OCPD floor is 23.24 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.0 * (1 + (-0.236/100) * (-10 - 25)) = 57.38 V | OCPD = 1.56 * 14.9 = 23.24 A

Inputs from CEC Modules.csv for CSI Solar Co Ltd CS61-72TB-630H: Voc=53.0 V, beta_Voc=-0.236%/C, Isc=14.9 A, STC=630.0 W, Area=2.62 m2.

Result: 10 panels max on 600 V (573.8 V); 13 panels for 8 kW (367 sq ft).

What Are the Published CEC Specifications for CSI Solar Co Ltd CS61-72TB-630H?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS61-72TB-630H.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd CS61-72TB-630H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 630.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 600.8 W (95.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.2 V / 13.94 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.236 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 24.05% (2.62 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many CSI Solar Co Ltd CS61-72TB-630H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS61-72TB-630H (630.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.3 kW 282 sq ft $1,577 $2,666
8 kW Class 13 8.19 kW 367 sq ft $2,050 $3,466
10 kW Class 16 10.08 kW 451 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?

All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS61-72TB-630H architecture.

Sibling CEC listings grouped into the CSI Solar Co Ltd CS61-72TB-630H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
CSI Solar Co Ltd CS61-72TB-625H 625.0 W 595.9 W 52.8 V 45.0 V 23.85%
CSI Solar Co Ltd CS61-72TB-630H 630.0 W 600.8 W 53.0 V 45.2 V 24.05%

How Many CSI Solar Co Ltd CS61-72TB-630H Modules Fit in a Cold-Weather String?

Maximum series module counts for CSI Solar Co Ltd CS61-72TB-630H from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=53.0V and beta_Voc=-0.236%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.63 V 10 panels 586.3 V 17 panels
-10 C (14 F) 57.38 V 10 panels 573.8 V 17 panels
0 C (32 F) 56.13 V 10 panels 561.3 V 17 panels
25 C (77 F STC) 53.0 V 11 panels 583.0 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS61-72TB-630H?

Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS61-72TB-630H (630.0 W), including FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-630.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-630
FS GREEN ENERGIES PRIVATE LIMITED
630.0 W Tie (0 W) 48.83 V 23.51% 94.9%
Philadelphia Solar PS-MNB156(HCBF)-635W
Philadelphia Solar
635.0 W +5.0 W 56.1 V 22.76% 94.3%
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-635
CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI
635.0 W +5.0 W 49.7 V 23.69% 94.6%
Jinko Solar Co Ltd JKM635N-66HL4M-BDV
Jinko Solar Co Ltd
635.0 W +5.0 W 49.68 V 23.52% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS61-72TB-630H?

Evaluate CSI Solar Co Ltd CS61-72TB-630H (630.0 W STC, 53.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS61-72TB-630H reaches 58.63 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 367 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS61-72TB-630H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

CSI Solar Co Ltd CS61-72TB-630H 8 kW Residential Fit

Needs 13 modules (367 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-630.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 600.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for CSI Solar Co Ltd CS61-72TB-630H by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS61-72TB-630H?

Multiplying CSI Solar Co Ltd CS61-72TB-630H's 14.9 A short-circuit current by 1.56 equals 23.24 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can CSI Solar Co Ltd CS61-72TB-630H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.38 V cold Voc at 14 F and handles 14.9 A Isc; string inverters cap CSI Solar Co Ltd CS61-72TB-630H at 10 panels on 600 V.

Is CSI Solar Co Ltd CS61-72TB-630H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS61-72TB-630H rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.