CSI Solar Co Ltd CS3L-320P is a 320.0 W STC (297.8 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 17.88% efficiency, 38.8 V Voc at 25 C, and 42.45 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 297.8 W
- Voc @ 25C
- 38.8 V
- Efficiency
- 17.88%
How Does CSI Solar Co Ltd CS3L-320P Compare Against Peer CEC Listings?
How CSI Solar Co Ltd CSI Solar Co Ltd CS3L-320P handles rooftop heat (297.8 W PTC), 8 kW sizing, and cold winter string voltage.
CSI Solar Co Ltd builds the CSI Solar Co Ltd CS3L-320P (Multi-c-Si) as a compact residential or specialty off-grid module delivering 178.8 W/m2 (2.03 percentage points below 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-120-MF23-320W {Blk} (320.0 W), this model holds strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Lower 38.8 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 16.63 A overcurrent floor served by a 20 A breaker.
Where Does CSI Solar Co Ltd CS3L-320P Fall Across Listed CEC Models?
Where CSI Solar Co Ltd CS3L-320P (320.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3L-320P?
Percentile placement of CSI Solar Co Ltd CS3L-320P across power density (178.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3L-320P?
Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS3L-320P specifications.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.88% Aperture Efficiency
Power density 178.8 W/m2 (2.03 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.45 V at -10 C (594.3 V string) and 43.5 V at -20 C (13 max).
25 Panels = 8,000 W STC
Occupies 44.8 m2 (482 sq ft) producing 7,445 W PTC; NEC 690.8 OCPD floor is 16.63 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.8 * (1 + (-0.269/100) * (-10 - 25)) = 42.45 V | OCPD = 1.56 * 10.66 = 16.63 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3L-320P: Voc=38.8 V, beta_Voc=-0.269%/C, Isc=10.66 A, STC=320.0 W, Area=1.79 m2.
Result: 14 panels max on 600 V (594.3 V); 25 panels for 8 kW (482 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3L-320P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS3L-320P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 297.8 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.66 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.8 V / 10.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.88% (1.79 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3L-320P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS3L-320P (320.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 366 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 482 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 617 sq ft | $2,563 | $4,334 |
How Many CSI Solar Co Ltd CS3L-320P Modules Fit in a Cold-Weather String?
Maximum series module counts for CSI Solar Co Ltd CS3L-320P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.5 V | 13 panels | 565.5 V | 22 panels |
| -10 C (14 F) | 42.45 V | 14 panels | 594.3 V | 23 panels |
| 0 C (32 F) | 41.41 V | 14 panels | 579.7 V | 24 panels |
| 25 C (77 F STC) | 38.8 V | 15 panels | 582.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3L-320P?
Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS3L-320P (320.0 W), including Aptos Solar Technology LLC DNA-120-MF23-320W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-MF23-320W {Blk} Aptos Solar Technology LLC |
320.0 W | Tie (0 W) | 39.92 V | 18.96% | 90.7% |
| Aptos Solar Technology LLC DNA-120-MF23-320W {Wht} Aptos Solar Technology LLC |
320.0 W | Tie (0 W) | 39.92 V | 19.63% | 93.4% |
| Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W Dehui Solar Power (Vietnam) CoLtd |
320.0 W | Tie (0 W) | 40.2 V | 19.88% | 92.9% |
| GCL System Integration Technology Co Ltd GCL-M6/60320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 40.3 V | 19.63% | 91.3% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3L-320P?
Evaluate CSI Solar Co Ltd CS3L-320P (320.0 W STC, 38.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3L-320P reaches 43.5 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 482 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (482 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3L-320P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3L-320P 8 kW Residential Fit
Needs 25 modules (482 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF23-320W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 297.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3L-320P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS3L-320P?
Multiplying CSI Solar Co Ltd CS3L-320P's 10.66 A short-circuit current by 1.56 equals 16.63 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS3L-320P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.45 V cold Voc at 14 F and handles 10.66 A Isc; string inverters cap CSI Solar Co Ltd CS3L-320P at 14 panels on 600 V.
Is CSI Solar Co Ltd CS3L-320P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS3L-320P rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)