CSI Solar Co Ltd CS1H-315MS is a 315.0 W STC (293.7 W PTC) Mono-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 19.33% efficiency, 43.2 V Voc at 25 C, and 47.36 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 315.0 W
- PTC Wattage
- 293.7 W
- Voc @ 25C
- 43.2 V
- Efficiency
- 19.33%
How Does CSI Solar Co Ltd CS1H-315MS Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS1H-315MS: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from CSI Solar Co Ltd and peers, CSI Solar Co Ltd CS1H-315MS stands 95.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (20 panels) to 10 kW (32 panels) yields $1,577-$2,523/yr in baseline US bill offset. Mid-range 43.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does CSI Solar Co Ltd CS1H-315MS Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS1H-315MS (315.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS1H-315MS?
Dataset percentiles tracking CSI Solar Co Ltd CS1H-315MS power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS1H-315MS?
Benchmark highlights for CSI Solar Co Ltd CS1H-315MS covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
315.0 W STC · Higher Than 27.3%
315.0 W STC (-70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.33% Aperture Efficiency
Power density 193.3 W/m2 (0.58 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.36 V at -10 C (568.3 V string) and 48.55 V at -20 C (12 max).
26 Panels = 8,190 W STC
Occupies 42.4 m2 (456 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 14.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.2 * (1 + (-0.275/100) * (-10 - 25)) = 47.36 V | OCPD = 1.56 * 9.44 = 14.73 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS1H-315MS: Voc=43.2 V, beta_Voc=-0.275%/C, Isc=9.44 A, STC=315.0 W, Area=1.63 m2.
Result: 12 panels max on 600 V (568.3 V); 26 panels for 8 kW (456 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS1H-315MS?
Official CEC datasheet figures for CSI Solar Co Ltd CS1H-315MS (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 293.7 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.44 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.4 V / 8.91 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.275 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.33% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS1H-315MS Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS1H-315MS modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.3 kW | 351 sq ft | $1,577 | $2,666 |
| 8 kW Class | 26 | 8.19 kW | 456 sq ft | $2,050 | $3,466 |
| 10 kW Class | 32 | 10.08 kW | 561 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS1H-315MS mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1H-310MS | 310.0 W | 288.9 W | 43.1 V | 35.2 V | 19.02% |
| CSI Solar Co Ltd CS1H-315MS | 315.0 W | 293.7 W | 43.2 V | 35.4 V | 19.33% |
| CSI Solar Co Ltd CS1H-320MS | 320.0 W | 298.4 W | 43.3 V | 35.6 V | 19.63% |
How Many CSI Solar Co Ltd CS1H-315MS Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS1H-315MS (47.36 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.55 V | 12 panels | 582.6 V | 20 panels |
| -10 C (14 F) | 47.36 V | 12 panels | 568.3 V | 21 panels |
| 0 C (32 F) | 46.17 V | 12 panels | 554.0 V | 21 panels |
| 25 C (77 F STC) | 43.2 V | 13 panels | 561.6 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS1H-315MS?
Competing CEC solar panels closest to CSI Solar Co Ltd CS1H-315MS in nameplate wattage and Voc, starting with Chinaland Solar Energy HSE310-72P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE310-72P Chinaland Solar Energy |
310.0 W | -5.0 W | 44.0 V | 16.06% | 88.6% |
| GCL System Integration Technology Co Ltd GCL-P6/72315 GCL System Integration Technology Co Ltd |
315.0 W | Tie (0 W) | 45.6 V | 16.23% | 90.5% |
| Centrosolar America EP72 315BW Centrosolar America |
315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| Centrosolar America EP72 315SW Centrosolar America |
315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS1H-315MS?
Evaluate CSI Solar Co Ltd CS1H-315MS (315.0 W STC, 43.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS1H-315MS reaches 48.55 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (456 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS1H-315MS carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS1H-315MS 8 kW Residential Fit
Needs 26 modules (456 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Chinaland Solar Energy HSE310-72P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 293.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS1H-315MS by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS1H-315MS?
Multiplying CSI Solar Co Ltd CS1H-315MS's 9.44 A short-circuit current by 1.56 equals 14.73 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS1H-315MS pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 47.36 V cold Voc at 14 F and handles 9.44 A Isc; string inverters cap CSI Solar Co Ltd CS1H-315MS at 12 panels on 600 V.
Is CSI Solar Co Ltd CS1H-315MS eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS1H-315MS rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)