Manufacturer: Zhejiang Hyxi Technology Co Ltd Registry: CEC Verified Engineering Specification

Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} outputs 478 W AC at 208 V, commercial single-phase (2.3 A continuous, 15 A OCPD), ranking #2,220 of 2,343 CEC inverters at 95.26% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
478 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
95.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} Compare Against Peer CEC Listings?

How Zhejiang Hyxi Technology Co Ltd Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} compares on 95.26% efficiency, MPPT span, and 120% busbar interconnection.

With a 35-50 V MPPT tracking band and 50 V DC ceiling, Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} handles 478 W continuous AC (4,522 W below the 5,000 W 208 V median). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Installers comparing Zhejiang Hyxi Technology Co Ltd against Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V} (475 W) should verify whether listed since 2025-03-21 grid-support firmware meets local IEEE 1547 utility rules.

Where Does Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} Fall Across Listed CEC Models?

Position of Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} (478 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} (478 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACZhejiang Hyxi Tech: 478 W

What Dataset Percentiles Define Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}?

Percentile placement of Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} across AC power class, conversion efficiency, and backfeed breaker size.

Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} Technical ThresholdsPercentile comparison for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output478 WCEC Efficiency95.26%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}.

Eff #2,220 / 2,343

95.26% CEC Weighted Efficiency

-1.15 pts vs the 96.41% 208 V median; overall power rank #1,959 (478 W, below CEC median; higher than 16.3% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 2.3 A = 2.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

35 V - 50 V (Max 50 V DC)

Tracking span of 15.0 V; listed since 2025-03-21 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 478.0W / 208 V -> 2.3 A | Breaker >= 1.25 * 2.3 = 2.9 A -> 15 A

CEC Inverters.csv for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}: Paco=478.0 W, Vac=208 V, Vdcmax=50.0 V, Eff=95.26%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}.

Official California Energy Commission (NREL SAM) test parameters for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 478 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 50 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 35 V - 50 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 11.9472 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.26% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-03-21 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} (208 V, commercial single-phase)?

Check whether Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} (15 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}?

Verified cold-weather (-10 C) series module counts matched to Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}'s 50 V DC ceiling.

Sampled CEC PV modules aligned within 35.0-50.0 V MPPT and 50.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}?

Alternative CEC inverters comparable to Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}, including Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V} (475 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V}
Enphase Energy Inc
475 W -3 W 208.0 V 53.0 V 97.21%
Enphase Energy Inc: IQ8P-3P-72-E-US {208V}
Enphase Energy Inc
475 W -3 W 208.0 V 53.0 V 97.21%
Enphase Energy Inc: IQ8P-3P-72-M-US {208V}
Enphase Energy Inc
475 W -3 W 208.0 V 53.0 V 97.21%
Enphase Energy Inc: IQ9N-A-DOM-US-HPB {208V}
Enphase Energy Inc
415 W -63 W 208.0 V 45.0 V 96.59%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}?

Check Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} (478 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V}.

Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.26%) and MPPT window (35-50 V) directly against Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V} (475 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} by Zhejiang Hyxi Technology Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} require?

At 478 W continuous AC (208 V, commercial single-phase), continuous current is 2.3 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} require?

At 478 W AC and 208 V, commercial single-phase, continuous line current is 2.3 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} compare to Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V}?

Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V} delivers 478 W AC at 95.26% CEC efficiency with a 50 V DC ceiling, while Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V} outputs 475 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.