Sparq Systems: Q1200-4101 {240V} outputs 1,165 W AC at 240 V (4.9 A continuous, 15 A OCPD), ranking #1,194 of 2,343 CEC inverters at 96.81% efficiency with a 28-31 V MPPT window and 31 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,165 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.81%
How Does Sparq Systems: Q1200-4101 {240V} Compare Against Peer CEC Listings?
How Sparq Systems Sparq Systems: Q1200-4101 {240V} compares on 96.81% efficiency, MPPT span, and 120% busbar interconnection. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Sparq Systems certifies Sparq Systems: Q1200-4101 {240V} (grid-tied PV inverter, listed since 2018-10-15) at 1,165 W AC (4,611 W below the 5,776 W 240 V median). Its 31 V DC ceiling pairs with an MPPT window of 28-31 V (span 3.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.
Where Does Sparq Systems: Q1200-4101 {240V} Fall Across Listed CEC Models?
Position of Sparq Systems: Q1200-4101 {240V} (1,165 W AC) relative to the 7,680 W CEC median inverter. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Sparq Systems: Q1200-4101 {240V}?
Percentile placement of Sparq Systems: Q1200-4101 {240V} across AC power class, conversion efficiency, and backfeed breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Sparq Systems: Q1200-4101 {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Sparq Systems: Q1200-4101 {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
96.81% CEC Weighted Efficiency
+0.13 pts vs the 96.68% 240 V median; overall power rank #1,816 (1,165 W, below CEC median; higher than 22.5% of peers).
15 A Required Backfeed OCPD
125% x 4.9 A = 6.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
28 V - 31 V (Max 31 V DC)
Tracking span of 3.0 V; listed since 2018-10-15 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1165.0W / 240 V -> 4.9 A | Breaker >= 1.25 * 4.9 = 6.1 A -> 15 A
CEC Inverters.csv for Sparq Systems: Q1200-4101 {240V}: Paco=1165.0 W, Vac=240 V, Vdcmax=31.0 V, Eff=96.81%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Sparq Systems: Q1200-4101 {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Sparq Systems: Q1200-4101 {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,165 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 31 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 28 V - 31 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 41.4967 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.81% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Sparq Systems: Q1200-4101 {240V}?
Check whether Sparq Systems: Q1200-4101 {240V} (15 A breaker) fits without main breaker derate or supply-side taps. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which Competing Grid-Support Inverters Compare to Sparq Systems: Q1200-4101 {240V}?
Alternative CEC inverters comparable to Sparq Systems: Q1200-4101 {240V}, including Altenergy Power System Inc: QS1 {240V} (1,225 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: QS1 {240V} Altenergy Power System Inc |
1,225 W | +60 W | 240.0 V | 48.0 V | 96.02% |
| Altenergy Power System Inc: QS1200 {240V} Altenergy Power System Inc |
1,225 W | +60 W | 240.0 V | 48.0 V | 96.02% |
| Altenergy Power System Inc: DS3-H {240V} Altenergy Power System Inc |
1,068 W | -97 W | 240.0 V | 43.0 V | 96.73% |
| Anker Innovations Limited: MI80H {240V} Anker Innovations Limited |
1,068 W | -97 W | 240.0 V | 43.0 V | 96.73% |
What Are the Interconnection Limits and Best-Fit Uses for Sparq Systems: Q1200-4101 {240V}?
Check Sparq Systems: Q1200-4101 {240V} (1,165 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 31 V DC on Sparq Systems: Q1200-4101 {240V}.
Sparq Systems: Q1200-4101 {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.81%) and MPPT window (28-31 V) directly against Altenergy Power System Inc: QS1 {240V} (1,225 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Sparq Systems: Q1200-4101 {240V} by Sparq Systems covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Sparq Systems: Q1200-4101 {240V} require?
At 1,165 W continuous AC (240 V), continuous current is 4.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Sparq Systems: Q1200-4101 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Sparq Systems: Q1200-4101 {240V} compare to Altenergy Power System Inc: QS1 {240V}?
Sparq Systems: Q1200-4101 {240V} delivers 1,165 W AC at 96.81% CEC efficiency with a 31 V DC ceiling, while Altenergy Power System Inc: QS1 {240V} outputs 1,225 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)