Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sparq Systems: Q1200-4101 {240V} — CEC Inverter Specifications

Manufacturer: Sparq Systems Registry: CEC Verified Engineering Specification

Sparq Systems: Q1200-4101 {240V} outputs 1,165 W AC at 240 V (4.9 A continuous, 15 A OCPD), ranking #1,194 of 2,343 CEC inverters at 96.81% efficiency with a 28-31 V MPPT window and 31 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,165 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sparq Systems: Q1200-4101 {240V} Compare Against Peer CEC Listings?

How Sparq Systems Sparq Systems: Q1200-4101 {240V} compares on 96.81% efficiency, MPPT span, and 120% busbar interconnection. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sparq Systems certifies Sparq Systems: Q1200-4101 {240V} (grid-tied PV inverter, listed since 2018-10-15) at 1,165 W AC (4,611 W below the 5,776 W 240 V median). Its 31 V DC ceiling pairs with an MPPT window of 28-31 V (span 3.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.

Where Does Sparq Systems: Q1200-4101 {240V} Fall Across Listed CEC Models?

Position of Sparq Systems: Q1200-4101 {240V} (1,165 W AC) relative to the 7,680 W CEC median inverter. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sparq Systems: Q1200-4101 {240V} (1,165 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSparq Systems: Q12: 1,165 W

What Dataset Percentiles Define Sparq Systems: Q1200-4101 {240V}?

Percentile placement of Sparq Systems: Q1200-4101 {240V} across AC power class, conversion efficiency, and backfeed breaker size. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sparq Systems: Q1200-4101 {240V} Technical ThresholdsPercentile comparison for Sparq Systems: Q1200-4101 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,165 WCEC Efficiency96.81%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Sparq Systems: Q1200-4101 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Sparq Systems: Q1200-4101 {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #1,194 / 2,343

96.81% CEC Weighted Efficiency

+0.13 pts vs the 96.68% 240 V median; overall power rank #1,816 (1,165 W, below CEC median; higher than 22.5% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 4.9 A = 6.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

28 V - 31 V (Max 31 V DC)

Tracking span of 3.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1165.0W / 240 V -> 4.9 A | Breaker >= 1.25 * 4.9 = 6.1 A -> 15 A

CEC Inverters.csv for Sparq Systems: Q1200-4101 {240V}: Paco=1165.0 W, Vac=240 V, Vdcmax=31.0 V, Eff=96.81%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Sparq Systems: Q1200-4101 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Sparq Systems: Q1200-4101 {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Sparq Systems: Q1200-4101 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,165 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 31 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 28 V - 31 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 41.4967 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.81% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Sparq Systems: Q1200-4101 {240V}?

Check whether Sparq Systems: Q1200-4101 {240V} (15 A breaker) fits without main breaker derate or supply-side taps. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Sparq Systems: Q1200-4101 {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which Competing Grid-Support Inverters Compare to Sparq Systems: Q1200-4101 {240V}?

Alternative CEC inverters comparable to Sparq Systems: Q1200-4101 {240V}, including Altenergy Power System Inc: QS1 {240V} (1,225 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: QS1 {240V}
Altenergy Power System Inc
1,225 W +60 W 240.0 V 48.0 V 96.02%
Altenergy Power System Inc: QS1200 {240V}
Altenergy Power System Inc
1,225 W +60 W 240.0 V 48.0 V 96.02%
Altenergy Power System Inc: DS3-H {240V}
Altenergy Power System Inc
1,068 W -97 W 240.0 V 43.0 V 96.73%
Anker Innovations Limited: MI80H {240V}
Anker Innovations Limited
1,068 W -97 W 240.0 V 43.0 V 96.73%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sparq Systems: Q1200-4101 {240V}?

Check Sparq Systems: Q1200-4101 {240V} (1,165 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 31 V DC on Sparq Systems: Q1200-4101 {240V}.

Sparq Systems: Q1200-4101 {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.81%) and MPPT window (28-31 V) directly against Altenergy Power System Inc: QS1 {240V} (1,225 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sparq Systems: Q1200-4101 {240V} by Sparq Systems covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Sparq Systems: Q1200-4101 {240V} require?

At 1,165 W continuous AC (240 V), continuous current is 4.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Sparq Systems: Q1200-4101 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Sparq Systems: Q1200-4101 {240V} compare to Altenergy Power System Inc: QS1 {240V}?

Sparq Systems: Q1200-4101 {240V} delivers 1,165 W AC at 96.81% CEC efficiency with a 31 V DC ceiling, while Altenergy Power System Inc: QS1 {240V} outputs 1,225 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.