Sol-Ark: Sol-Ark-9k-48-ST {208V} outputs 8,818 W AC at 208 V, commercial single-phase (42.4 A continuous, 60 A OCPD), ranking #1,083 of 2,343 CEC inverters at 96.95% efficiency with a 240-425 V MPPT window and 425 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 8,818 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.95%
How Does Sol-Ark: Sol-Ark-9k-48-ST {208V} Compare Against Peer CEC Listings?
Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Sol-Ark: Sol-Ark-9k-48-ST {208V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
For NEC 705.12 solar interconnection, Sol-Ark: Sol-Ark-9k-48-ST {208V} outputs 42.4 A continuous AC at 208 V, commercial single-phase and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.95% (#1,083 of 2,343, +0.13 pts vs overall CEC median).
Where Does Sol-Ark: Sol-Ark-9k-48-ST {208V} Fall Across Listed CEC Models?
Output power comparison showing where Sol-Ark: Sol-Ark-9k-48-ST {208V} sits among all 2,343 CEC-listed grid-support inverters. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Sol-Ark: Sol-Ark-9k-48-ST {208V}?
Relative ranking of Sol-Ark: Sol-Ark-9k-48-ST {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Do the Dataset Ranks Show for Sol-Ark: Sol-Ark-9k-48-ST {208V}?
Snapshot of Sol-Ark: Sol-Ark-9k-48-ST {208V} efficiency rank (#1,083), OCPD breaker size, MPPT span, and busbar verdict. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
96.95% CEC Weighted Efficiency
+0.54 pts vs the 96.41% 208 V median; overall power rank #1,031 (8,818 W, top 44.0%; higher than 56.0% of peers).
60 A Required Backfeed OCPD
125% x 42.4 A = 53.0 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
240 V - 425 V (Max 425 V DC)
Tracking span of 185.0 V; listed since 2023-04-11 (hybrid battery-capable inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 8818.0W / 208 V -> 42.4 A | Breaker >= 1.25 * 42.4 = 53.0 A -> 60 A
CEC Inverters.csv for Sol-Ark: Sol-Ark-9k-48-ST {208V}: Paco=8818.0 W, Vac=208 V, Vdcmax=425.0 V, Eff=96.95%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Sol-Ark: Sol-Ark-9k-48-ST {208V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Sol-Ark: Sol-Ark-9k-48-ST {208V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 8,818 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 425 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 240 V - 425 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 24.5832 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.95% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-04-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Sol-Ark: Sol-Ark-9k-48-ST {208V} (208 V, commercial single-phase)?
NEC 705.12(B)(3)(2) backfeed compliance table for Sol-Ark: Sol-Ark-9k-48-ST {208V} at 208 V, commercial single-phase. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Sol-Ark: Sol-Ark-9k-48-ST {208V}?
Minimum and maximum series solar module strings fitting Sol-Ark: Sol-Ark-9k-48-ST {208V} MPPT and 425 V limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 10 panels | 2.0 kW |
Which Competing Grid-Support Inverters Compare to Sol-Ark: Sol-Ark-9k-48-ST {208V}?
Peer 208 V, commercial single-phase CEC inverters near 8,818 W AC output such as Delta Electronics: E10_BDI {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E10_BDI {208V} Delta Electronics |
8,400 W | -418 W | 208.0 V | 480.0 V | 96.86% |
| Delta Electronics: E10-TL-US {208V} Delta Electronics |
8,400 W | -418 W | 208.0 V | 480.0 V | 96.86% |
| Delta Electronics: M10-4-TL-US {208V} Delta Electronics |
8,385 W | -433 W | 208.0 V | 480.0 V | 96.94% |
| Delta Electronics: M10-TL-US {208V} Delta Electronics |
8,360 W | -458 W | 208.0 V | 480.0 V | 96.83% |
What Are the Interconnection Limits and Best-Fit Uses for Sol-Ark: Sol-Ark-9k-48-ST {208V}?
Check Sol-Ark: Sol-Ark-9k-48-ST {208V} (8,818 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 425 V DC on Sol-Ark: Sol-Ark-9k-48-ST {208V}.
Sol-Ark: Sol-Ark-9k-48-ST {208V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (42.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.95%) and MPPT window (240-425 V) directly against Delta Electronics: E10_BDI {208V} (8,400 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Sol-Ark: Sol-Ark-9k-48-ST {208V} by Sol-Ark covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Sol-Ark: Sol-Ark-9k-48-ST {208V} require?
At 8,818 W continuous AC (208 V, commercial single-phase), continuous current is 42.4 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Sol-Ark: Sol-Ark-9k-48-ST {208V} require?
At 8,818 W AC and 208 V, commercial single-phase, continuous line current is 42.4 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Sol-Ark: Sol-Ark-9k-48-ST {208V} compare to Delta Electronics: E10_BDI {208V}?
Sol-Ark: Sol-Ark-9k-48-ST {208V} delivers 8,818 W AC at 96.95% CEC efficiency with a 425 V DC ceiling, while Delta Electronics: E10_BDI {208V} outputs 8,400 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)