Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} — CEC Inverter Specifications

Manufacturer: SHENZHENMYSMARTENERGYELECTRICCO LTD Registry: CEC Verified Engineering Specification

SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} outputs 15,015 W AC at 240 V (62.6 A continuous, 80 A OCPD), ranking #1,798 of 2,343 CEC inverters at 96.27% efficiency with a 202-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
15,015 W
AC Voltage
240 V
Min PV Breaker
80 A (4 AWG Cu)
CEC Efficiency
96.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} Compare Against Peer CEC Listings?

Breaker sizing (80 A), 4 AWG Cu wire rules, and DC input limits for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} requires 78.2 A design capacity -> 80 A breaker using 4 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 96.27% (-0.55 pts vs overall CEC median) across 2,343 CEC models, while its 80 a backfeed breaker exceeds a 200a/200a panel's 40 a ceiling, requiring a 175 a main derate, 225 a busbar, or nec 705.11 tap.

Where Does SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} Fall Across Listed CEC Models?

Output power comparison showing where SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} sits among all 2,343 CEC-listed grid-support inverters. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} (15,015 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSHENZHENMYSMARTENE: 15,015 W

What Dataset Percentiles Define SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

Relative ranking of SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} Technical ThresholdsPercentile comparison for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output15,015 WCEC Efficiency96.27%Backfeed Breaker80 A

What Do the Dataset Ranks Show for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

Snapshot of SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} efficiency rank (#1,798), OCPD breaker size, MPPT span, and busbar verdict. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #1,798 / 2,343

96.27% CEC Weighted Efficiency

-0.41 pts vs the 96.68% 240 V median; overall power rank #668 (15,015 W, top 28.6%; higher than 71.4% of peers).

NEC 705.12 Check

80 A Required Backfeed OCPD

125% x 62.6 A = 78.2 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

202 V - 480 V (Max 480 V DC)

Tracking span of 278.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 15014.8W / 240 V -> 62.6 A | Breaker >= 1.25 * 62.6 = 78.2 A -> 80 A

CEC Inverters.csv for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}: Paco=15014.8 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.27%.

Result: Min 80 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 15,015 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 202 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 41.0434 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.27% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} at 240 V. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Evaluates SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} (80 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 80 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 80 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 80 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 80 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 80 A Needs Derate / Tap 705.11

Which CEC PV Module Strings Pair With SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

Minimum and maximum series solar module strings fitting SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} MPPT and 480 V limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sampled CEC PV modules aligned within 202.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

Peer 240 V CEC inverters near 15,015 W AC output such as Amensolar Ess Co Ltd: N3H-X16US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X16US {240V}
Amensolar Ess Co Ltd
16,199 W +1184 W 240.0 V 430.0 V 96.25%
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W -2801 W 240.0 V 430.0 V 96.17%
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W -3025 W 240.0 V 480.0 V 96.59%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -3426 W 240.0 V 480.0 V 96.99%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}?

Check SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} (15,015 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 80 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V}.

SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (62.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.27%) and MPPT window (202-480 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} by SHENZHENMYSMARTENERGYELECTRICCO LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} require?

At 15,015 W continuous AC (240 V), continuous current is 62.6 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

Does SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 80 A at 240 V means Needs Derate / Tap 705.11.

How does SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?

SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V} delivers 15,015 W AC at 96.27% CEC efficiency with a 480 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.