RNG International Inc: RIV4850HI-SPS {240V} — CEC Inverter Specifications

Manufacturer: RNG International Inc Registry: CEC Verified Engineering Specification

RNG International Inc: RIV4850HI-SPS {240V} outputs 5,090 W AC at 240 V (21.2 A continuous, 30 A OCPD), ranking #1,019 of 2,343 CEC inverters at 96.99% efficiency with a 180-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,090 W
AC Voltage
240 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
96.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does RNG International Inc: RIV4850HI-SPS {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,019), 180-430 V MPPT tracking, and panel fit for RNG International Inc: RIV4850HI-SPS {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

RNG International Inc: RIV4850HI-SPS {240V} from RNG International Inc outputs 21.2 A continuous AC at 240 V (5,090 W AC, rank #1,473). Paired with 10 AWG Cu conductors and a 30 A OCPD, its 96.99% CEC efficiency compares closely with Amensolar Ess Co Ltd: N3H-X50-US {240V} (5,090 W). Keep NEC 690.7 winter string Voc below 430 V DC.

Where Does RNG International Inc: RIV4850HI-SPS {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting RNG International Inc: RIV4850HI-SPS {240V} at 5,090 W continuous AC output. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where RNG International Inc: RIV4850HI-SPS {240V} (5,090 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACRNG International : 5,090 W

What Dataset Percentiles Define RNG International Inc: RIV4850HI-SPS {240V}?

Dataset percentiles comparing RNG International Inc: RIV4850HI-SPS {240V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

RNG International Inc: RIV4850HI-SPS {240V} Technical ThresholdsPercentile comparison for RNG International Inc: RIV4850HI-SPS {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,090 WCEC Efficiency96.99%Backfeed Breaker30 A

What Do the Dataset Ranks Show for RNG International Inc: RIV4850HI-SPS {240V}?

Engineering highlights for RNG International Inc: RIV4850HI-SPS {240V} covering efficiency, 10 AWG Cu feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #1,019 / 2,343

96.99% CEC Weighted Efficiency

+0.31 pts vs the 96.68% 240 V median; overall power rank #1,473 (5,090 W, below CEC median; higher than 37.0% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 21.2 A = 26.5 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

180 V - 430 V (Max 430 V DC)

Tracking span of 250.0 V; listed since 2024-09-03 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5089.7W / 240 V -> 21.2 A | Breaker >= 1.25 * 21.2 = 26.5 A -> 30 A

CEC Inverters.csv for RNG International Inc: RIV4850HI-SPS {240V}: Paco=5089.7 W, Vac=240 V, Vdcmax=430.0 V, Eff=96.99%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for RNG International Inc: RIV4850HI-SPS {240V}?

California Energy Commission Solar Equipment List parameters for RNG International Inc: RIV4850HI-SPS {240V} (hybrid battery-capable inverter) interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for RNG International Inc: RIV4850HI-SPS {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,090 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 430 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 180 V - 430 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 14.5766 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.99% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-09-03 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for RNG International Inc: RIV4850HI-SPS {240V}?

Panelboard and switchgear backfeed allowances for RNG International Inc: RIV4850HI-SPS {240V} (30 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates RNG International Inc: RIV4850HI-SPS {240V} (30 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 30 A PASS (120% Rule)
200A Bus / 200A Main 40 A 30 A PASS (120% Rule)
200A Bus / 175A Main 65 A 30 A PASS (120% Rule)
225A Bus / 200A Main 70 A 30 A PASS (120% Rule)

Which CEC PV Module Strings Pair With RNG International Inc: RIV4850HI-SPS {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for RNG International Inc: RIV4850HI-SPS {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 180.0-430.0 V MPPT and 430.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 9 panels 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 10 panels 2.0 kW

Which Competing Grid-Support Inverters Compare to RNG International Inc: RIV4850HI-SPS {240V}?

Four alternative CEC inverters matched to RNG International Inc: RIV4850HI-SPS {240V} (5,090 W AC), led by Amensolar Ess Co Ltd: N3H-X50-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X50-US {240V}
Amensolar Ess Co Ltd
5,090 W Tie (0 W) 240.0 V 430.0 V 96.99%
Amensolar Ess Co Ltd: N3H-X5US {240V}
Amensolar Ess Co Ltd
5,090 W Tie (0 W) 240.0 V 430.0 V 96.99%
Darfon Electronics Corp: H5000xxxxxx {240V}
Darfon Electronics Corp
5,074 W -16 W 240.0 V 380.0 V 95.84%
Dyness Digital Energy Technology Co LTD: TX5K-HM {240V}
Dyness Digital Energy Technology Co LTD
5,020 W -70 W 240.0 V 500.0 V 97.05%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for RNG International Inc: RIV4850HI-SPS {240V}?

Check RNG International Inc: RIV4850HI-SPS {240V} (5,090 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on RNG International Inc: RIV4850HI-SPS {240V}.

RNG International Inc: RIV4850HI-SPS {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (21.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.99%) and MPPT window (180-430 V) directly against Amensolar Ess Co Ltd: N3H-X50-US {240V} (5,090 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for RNG International Inc: RIV4850HI-SPS {240V} by RNG International Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does RNG International Inc: RIV4850HI-SPS {240V} require?

At 5,090 W continuous AC (240 V), continuous current is 21.2 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does RNG International Inc: RIV4850HI-SPS {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

How does RNG International Inc: RIV4850HI-SPS {240V} compare to Amensolar Ess Co Ltd: N3H-X50-US {240V}?

RNG International Inc: RIV4850HI-SPS {240V} delivers 5,090 W AC at 96.99% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X50-US {240V} outputs 5,090 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.