Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Qcells North America: QMICRO380C-G2 {208V} — CEC Inverter Specifications

Manufacturer: Qcells North America Registry: CEC Verified Engineering Specification

Qcells North America: QMICRO380C-G2 {208V} outputs 330 W AC at 208 V, commercial single-phase (1.6 A continuous, 15 A OCPD), ranking #1,263 of 2,343 CEC inverters at 96.71% efficiency with a 29.5-41 V MPPT window and 41 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
330 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Qcells North America: QMICRO380C-G2 {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Qcells North America: QMICRO380C-G2 {208V}.

Rated at 330 W AC (1.6 A continuous), Qcells North America: QMICRO380C-G2 {208V} ranks #1,263 of 2,343 CEC units at 96.71% efficiency (+0.30 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 15 A circuit is 14 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 41 V DC at record local winter lows.

Where Does Qcells North America: QMICRO380C-G2 {208V} Fall Across Listed CEC Models?

Marks Qcells North America: QMICRO380C-G2 {208V} (330 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Qcells North America: QMICRO380C-G2 {208V} (330 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACQcells North Ameri: 330 W

What Dataset Percentiles Define Qcells North America: QMICRO380C-G2 {208V}?

Benchmarks Qcells North America: QMICRO380C-G2 {208V} continuous AC output, 96.71% CEC weighted efficiency, and 15 A OCPD breaker demand.

Qcells North America: QMICRO380C-G2 {208V} Technical ThresholdsPercentile comparison for Qcells North America: QMICRO380C-G2 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output330 WCEC Efficiency96.71%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Qcells North America: QMICRO380C-G2 {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Qcells North America: QMICRO380C-G2 {208V} by Qcells North America.

Eff #1,263 / 2,343

96.71% CEC Weighted Efficiency

+0.30 pts vs the 96.41% 208 V median; overall power rank #2,129 (330 W, below CEC median; higher than 9.1% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 1.6 A = 2.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

29.5 V - 41 V (Max 41 V DC)

Tracking span of 11.5 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 330.2W / 208 V -> 1.6 A | Breaker >= 1.25 * 1.6 = 2.0 A -> 15 A

CEC Inverters.csv for Qcells North America: QMICRO380C-G2 {208V}: Paco=330.2 W, Vac=208 V, Vdcmax=41.0 V, Eff=96.71%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Qcells North America: QMICRO380C-G2 {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Qcells North America: QMICRO380C-G2 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Qcells North America: QMICRO380C-G2 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 330 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 41 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 29.5 V - 41 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 10.5059 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.71% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Qcells North America: QMICRO380C-G2 {208V} (208 V, commercial single-phase)?

Evaluates Qcells North America: QMICRO380C-G2 {208V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Qcells North America: QMICRO380C-G2 {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Qcells North America: QMICRO380C-G2 {208V}?

Sample PV string lengths aligned within 29.5-41 V MPPT and 41 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 29.5-41.0 V MPPT and 41.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW

Which Competing Grid-Support Inverters Compare to Qcells North America: QMICRO380C-G2 {208V}?

Competing CEC grid-support inverters near 330 W AC and 208 V, commercial single-phase, led by Enphase Energy Inc: IQ8AC-72-2-US {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Enphase Energy Inc: IQ8AC-72-2-US {208V}
Enphase Energy Inc
344 W +14 W 208.0 V 45.0 V 95.88%
Enphase Energy Inc: IQ8AC-72-M-DOM-US {208V}
Enphase Energy Inc
345 W +15 W 208.0 V 45.0 V 95.98%
Enphase Energy Inc: IQ8AC-72-M-F-US {208V}
Enphase Energy Inc
345 W +15 W 208.0 V 45.0 V 95.98%
Enphase Energy Inc: IQ8AC-72-M-US {208V}
Enphase Energy Inc
345 W +15 W 208.0 V 45.0 V 95.96%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Qcells North America: QMICRO380C-G2 {208V}?

Check Qcells North America: QMICRO380C-G2 {208V} (330 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 41 V DC on Qcells North America: QMICRO380C-G2 {208V}.

Qcells North America: QMICRO380C-G2 {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.71%) and MPPT window (29.5-41 V) directly against Enphase Energy Inc: IQ8AC-72-2-US {208V} (344 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Qcells North America: QMICRO380C-G2 {208V} by Qcells North America covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Qcells North America: QMICRO380C-G2 {208V} require?

At 330 W continuous AC (208 V, commercial single-phase), continuous current is 1.6 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Qcells North America: QMICRO380C-G2 {208V} require?

At 330 W AC and 208 V, commercial single-phase, continuous line current is 1.6 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Qcells North America: QMICRO380C-G2 {208V} compare to Enphase Energy Inc: IQ8AC-72-2-US {208V}?

Qcells North America: QMICRO380C-G2 {208V} delivers 330 W AC at 96.71% CEC efficiency with a 41 V DC ceiling, while Enphase Energy Inc: IQ8AC-72-2-US {208V} outputs 344 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.