PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} outputs 8,084 W AC at 240 V (33.7 A continuous, 45 A OCPD), ranking #896 of 2,343 CEC inverters at 97.09% efficiency with a 250-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 8,084 W
- AC Voltage
- 240 V
- Min PV Breaker
- 45 A (8 AWG Cu)
- CEC Efficiency
- 97.09%
How Does PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Rated at 8,084 W AC (33.7 A continuous), PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} ranks #896 of 2,343 CEC units at 97.09% efficiency (+0.41 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 45 A circuit is 8 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 430 V DC at record local winter lows.
Where Does PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} Fall Across Listed CEC Models?
Marks PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} (8,084 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Benchmarks PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} continuous AC output, 97.09% CEC weighted efficiency, and 45 A OCPD breaker demand.
What Do the Dataset Ranks Show for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} by PhaseGreen Technology Inc.
97.09% CEC Weighted Efficiency
+0.41 pts vs the 96.68% 240 V median; overall power rank #1,099 (8,084 W, top 47.2%; higher than 52.8% of peers).
45 A Required Backfeed OCPD
125% x 33.7 A = 42.1 A -> 45 A standard OCPD using 8 AWG Cu (75 C).
250 V - 430 V (Max 430 V DC)
Tracking span of 180.0 V; listed since 2026-03-11 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 8084.0W / 240 V -> 33.7 A | Breaker >= 1.25 * 33.7 = 42.1 A -> 45 A
CEC Inverters.csv for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}: Paco=8084.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=97.09%.
Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 8,084 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 250 V - 430 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 23.1297 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.09% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2026-03-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Evaluates PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} (45 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 45 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 45 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 45 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 45 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 45 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Sample PV string lengths aligned within 250-430 V MPPT and 430 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 9 panels | 3.83 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 10 panels | 2.0 kW |
Which Competing Grid-Support Inverters Compare to PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Competing CEC grid-support inverters near 8,084 W AC and 240 V, led by Amensolar Ess Co Ltd: N3H-X80-US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Amensolar Ess Co Ltd: N3H-X80-US {240V} Amensolar Ess Co Ltd |
8,084 W | Tie (0 W) | 240.0 V | 430.0 V | 97.08% |
| Amensolar Ess Co Ltd: N3H-X8US {240V} Amensolar Ess Co Ltd |
8,084 W | Tie (0 W) | 240.0 V | 430.0 V | 97.08% |
| Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
7,999 W | -85 W | 240.0 V | 480.0 V | 97.79% |
| Base Power Inc: MIN 8200TL-XH-US {240V} Base Power Inc |
8,251 W | +167 W | 240.0 V | 480.0 V | 97.7% |
What Are the Interconnection Limits and Best-Fit Uses for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}?
Check PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} (8,084 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V}.
PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (33.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.09%) and MPPT window (250-430 V) directly against Amensolar Ess Co Ltd: N3H-X80-US {240V} (8,084 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} by PhaseGreen Technology Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} require?
At 8,084 W continuous AC (240 V), continuous current is 33.7 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.
Does PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.
How does PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} compare to Amensolar Ess Co Ltd: N3H-X80-US {240V}?
PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V} delivers 8,084 W AC at 97.09% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X80-US {240V} outputs 8,084 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)