Northern Electric & Power Co Ltd: BDM-1600-208A {208V} outputs 1,331 W AC at 208 V, commercial single-phase (6.4 A continuous, 15 A OCPD), ranking #1,831 of 2,343 CEC inverters at 96.21% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,331 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.21%
How Does Northern Electric & Power Co Ltd: BDM-1600-208A {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,831), 22-55 V MPPT tracking, and panel fit for Northern Electric & Power Co Ltd: BDM-1600-208A {208V}.
Operating at 208 V, commercial single-phase, Northern Electric & Power Co Ltd: BDM-1600-208A {208V} converts DC array energy at 96.21% CEC weighted efficiency (below overall CEC median; higher than 21.6% of peers) with a 55 V max DC input and 39.5263 A max input current for NEC 690.7 string safety. Compare this 1,331 W grid-tied PV inverter directly with Altenergy Power System Inc: QS1 {208V} (1,218 W). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
Where Does Northern Electric & Power Co Ltd: BDM-1600-208A {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Northern Electric & Power Co Ltd: BDM-1600-208A {208V} at 1,331 W continuous AC output.
What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-1600-208A {208V}?
Dataset percentiles comparing Northern Electric & Power Co Ltd: BDM-1600-208A {208V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-1600-208A {208V}?
Engineering highlights for Northern Electric & Power Co Ltd: BDM-1600-208A {208V} covering efficiency, 14 AWG Cu feeder, and panel compatibility.
96.21% CEC Weighted Efficiency
-0.20 pts vs the 96.41% 208 V median; overall power rank #1,800 (1,331 W, below CEC median; higher than 23.2% of peers).
15 A Required Backfeed OCPD
125% x 6.4 A = 8.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
22 V - 55 V (Max 55 V DC)
Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1331.0W / 208 V -> 6.4 A | Breaker >= 1.25 * 6.4 = 8.0 A -> 15 A
CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-1600-208A {208V}: Paco=1331.0 W, Vac=208 V, Vdcmax=55.0 V, Eff=96.21%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-1600-208A {208V}?
California Energy Commission Solar Equipment List parameters for Northern Electric & Power Co Ltd: BDM-1600-208A {208V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,331 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 39.5263 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.21% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Northern Electric & Power Co Ltd: BDM-1600-208A {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for Northern Electric & Power Co Ltd: BDM-1600-208A {208V} (15 A OCPD). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-1600-208A {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Northern Electric & Power Co Ltd: BDM-1600-208A {208V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |
Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-1600-208A {208V}?
Four alternative CEC inverters matched to Northern Electric & Power Co Ltd: BDM-1600-208A {208V} (1,331 W AC), led by Altenergy Power System Inc: QS1 {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: QS1 {208V} Altenergy Power System Inc |
1,218 W | -113 W | 208.0 V | 48.0 V | 95.82% |
| Cherry Solution Co Ltd: CMI-1000S-SA {208V} Cherry Solution Co Ltd |
994 W | -337 W | 208.0 V | 50.0 V | 96.35% |
| Cherry Solution Co Ltd: CMI-1000S-WA {208V} Cherry Solution Co Ltd |
994 W | -337 W | 208.0 V | 50.0 V | 96.35% |
| Altenergy Power System Inc: QT2-208 {208V} Altenergy Power System Inc |
1,733 W | +402 W | 208.0 V | 42.0 V | 95.57% |
What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-1600-208A {208V}?
Check Northern Electric & Power Co Ltd: BDM-1600-208A {208V} (1,331 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-1600-208A {208V}.
Northern Electric & Power Co Ltd: BDM-1600-208A {208V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (6.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.21%) and MPPT window (22-55 V) directly against Altenergy Power System Inc: QS1 {208V} (1,218 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Northern Electric & Power Co Ltd: BDM-1600-208A {208V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Northern Electric & Power Co Ltd: BDM-1600-208A {208V} require?
At 1,331 W continuous AC (208 V, commercial single-phase), continuous current is 6.4 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Northern Electric & Power Co Ltd: BDM-1600-208A {208V} require?
At 1,331 W AC and 208 V, commercial single-phase, continuous line current is 6.4 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Northern Electric & Power Co Ltd: BDM-1600-208A {208V} compare to Altenergy Power System Inc: QS1 {208V}?
Northern Electric & Power Co Ltd: BDM-1600-208A {208V} delivers 1,331 W AC at 96.21% CEC efficiency with a 55 V DC ceiling, while Altenergy Power System Inc: QS1 {208V} outputs 1,218 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)