Manufacturer: Northern Electric & Power Co Ltd Registry: CEC Verified Engineering Specification

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} outputs 1,070 W AC at 208 V, commercial single-phase (5.1 A continuous, 15 A OCPD), ranking #1,589 of 2,343 CEC inverters at 96.48% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,070 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,589), 22-55 V MPPT tracking, and panel fit for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} from Northern Electric & Power Co Ltd outputs 5.1 A continuous AC at 208 V, commercial single-phase (1,070 W AC, rank #1,817). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.48% CEC efficiency compares closely with Cherry Solution Co Ltd: CMI-1000S-SA {208V} (994 W). Keep NEC 690.7 winter string Voc below 55 V DC.

Where Does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Northern Electric & Power Co Ltd: BDM-1200-208A {208V} at 1,070 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (1,070 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACNorthern Electric : 1,070 W

What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Dataset percentiles comparing Northern Electric & Power Co Ltd: BDM-1200-208A {208V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Technical ThresholdsPercentile comparison for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,070 WCEC Efficiency96.48%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Engineering highlights for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} covering efficiency, 14 AWG Cu feeder, and panel compatibility.

Eff #1,589 / 2,343

96.48% CEC Weighted Efficiency

+0.07 pts vs the 96.41% 208 V median; overall power rank #1,817 (1,070 W, below CEC median; higher than 22.4% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 5.1 A = 6.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1070.0W / 208 V -> 5.1 A | Breaker >= 1.25 * 5.1 = 6.4 A -> 15 A

CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}: Paco=1070.0 W, Vac=208 V, Vdcmax=55.0 V, Eff=96.48%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

California Energy Commission Solar Equipment List parameters for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,070 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 55 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 22 V - 55 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 31.6874 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.48% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-11-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (15 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 1 panel (micro/module) 0.52 kW

Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Four alternative CEC inverters matched to Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (1,070 W AC), led by Cherry Solution Co Ltd: CMI-1000S-SA {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Cherry Solution Co Ltd: CMI-1000S-SA {208V}
Cherry Solution Co Ltd
994 W -76 W 208.0 V 50.0 V 96.35%
Cherry Solution Co Ltd: CMI-1000S-WA {208V}
Cherry Solution Co Ltd
994 W -76 W 208.0 V 50.0 V 96.35%
Altenergy Power System Inc: QS1 {208V}
Altenergy Power System Inc
1,218 W +148 W 208.0 V 48.0 V 95.82%
Cherry Solution Co Ltd: CMI-800S-SA {208V}
Cherry Solution Co Ltd
800 W -270 W 208.0 V 50.0 V 95.84%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-1200-208A {208V}?

Check Northern Electric & Power Co Ltd: BDM-1200-208A {208V} (1,070 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-1200-208A {208V}.

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (5.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.48%) and MPPT window (22-55 V) directly against Cherry Solution Co Ltd: CMI-1000S-SA {208V} (994 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Northern Electric & Power Co Ltd: BDM-1200-208A {208V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} require?

At 1,070 W continuous AC (208 V, commercial single-phase), continuous current is 5.1 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} require?

At 1,070 W AC and 208 V, commercial single-phase, continuous line current is 5.1 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Northern Electric & Power Co Ltd: BDM-1200-208A {208V} compare to Cherry Solution Co Ltd: CMI-1000S-SA {208V}?

Northern Electric & Power Co Ltd: BDM-1200-208A {208V} delivers 1,070 W AC at 96.48% CEC efficiency with a 55 V DC ceiling, while Cherry Solution Co Ltd: CMI-1000S-SA {208V} outputs 994 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.