Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Lunar Energy Inc: 10-005025 {240V} — CEC Inverter Specifications

Manufacturer: Lunar Energy Inc Registry: CEC Verified Engineering Specification

Lunar Energy Inc: 10-005025 {240V} outputs 9,675 W AC at 240 V (40.3 A continuous, 60 A OCPD), ranking #1,861 of 2,343 CEC inverters at 96.14% efficiency with a 380-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,675 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lunar Energy Inc: 10-005025 {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Lunar Energy Inc: 10-005025 {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Ranking #951 of 2,343 CEC inverters (top 40.6%; higher than 59.4% of peers), Lunar Energy Inc: 10-005025 {240V} is a hybrid battery-capable inverter delivering 9,675 W continuous AC at 240 V (40.3 A continuous). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 96.14% (-0.54 pts vs the 96.68% 240 V median) against peers like Delta Electronics: E10_BDI {240V} (9,674 W).

Where Does Lunar Energy Inc: 10-005025 {240V} Fall Across Listed CEC Models?

Marks Lunar Energy Inc: 10-005025 {240V} (9,675 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Lunar Energy Inc: 10-005025 {240V} (9,675 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACLunar Energy Inc: : 9,675 W

What Dataset Percentiles Define Lunar Energy Inc: 10-005025 {240V}?

Benchmarks Lunar Energy Inc: 10-005025 {240V} continuous AC output, 96.14% CEC weighted efficiency, and 60 A OCPD breaker demand.

Lunar Energy Inc: 10-005025 {240V} Technical ThresholdsPercentile comparison for Lunar Energy Inc: 10-005025 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,675 WCEC Efficiency96.14%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Lunar Energy Inc: 10-005025 {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Lunar Energy Inc: 10-005025 {240V} by Lunar Energy Inc.

Eff #1,861 / 2,343

96.14% CEC Weighted Efficiency

-0.54 pts vs the 96.68% 240 V median; overall power rank #951 (9,675 W, top 40.6%; higher than 59.4% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 40.3 A = 50.4 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

380 V - 450 V (Max 450 V DC)

Tracking span of 70.0 V; listed since 2025-10-21 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9675.0W / 240 V -> 40.3 A | Breaker >= 1.25 * 40.3 = 50.4 A -> 60 A

CEC Inverters.csv for Lunar Energy Inc: 10-005025 {240V}: Paco=9675.0 W, Vac=240 V, Vdcmax=450.0 V, Eff=96.14%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Lunar Energy Inc: 10-005025 {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Lunar Energy Inc: 10-005025 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Lunar Energy Inc: 10-005025 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,675 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 450 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 380 V - 450 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 24.2485 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.14% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-10-21 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Lunar Energy Inc: 10-005025 {240V}?

Evaluates Lunar Energy Inc: 10-005025 {240V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Lunar Energy Inc: 10-005025 {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which Competing Grid-Support Inverters Compare to Lunar Energy Inc: 10-005025 {240V}?

Competing CEC grid-support inverters near 9,675 W AC and 240 V, led by Delta Electronics: E10_BDI {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E10_BDI {240V}
Delta Electronics
9,674 W -1 W 240.0 V 480.0 V 97.21%
Delta Electronics: E10-TL-US {240V}
Delta Electronics
9,674 W -1 W 240.0 V 480.0 V 97.21%
Delta Electronics: M10-4-TL-US {240V}
Delta Electronics
9,674 W -1 W 240.0 V 480.0 V 97.21%
Dyness Digital Energy Technology Co LTD: TX96K-AM {240V}
Dyness Digital Energy Technology Co LTD
9,662 W -13 W 240.0 V 490.0 V 96.46%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Lunar Energy Inc: 10-005025 {240V}?

Check Lunar Energy Inc: 10-005025 {240V} (9,675 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on Lunar Energy Inc: 10-005025 {240V}.

Lunar Energy Inc: 10-005025 {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.14%) and MPPT window (380-450 V) directly against Delta Electronics: E10_BDI {240V} (9,674 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Lunar Energy Inc: 10-005025 {240V} by Lunar Energy Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Lunar Energy Inc: 10-005025 {240V} require?

At 9,675 W continuous AC (240 V), continuous current is 40.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Lunar Energy Inc: 10-005025 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Lunar Energy Inc: 10-005025 {240V} compare to Delta Electronics: E10_BDI {240V}?

Lunar Energy Inc: 10-005025 {240V} delivers 9,675 W AC at 96.14% CEC efficiency with a 450 V DC ceiling, while Delta Electronics: E10_BDI {240V} outputs 9,674 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.