Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Lion Energy: #50170168 {240V} — CEC Inverter Specifications

Manufacturer: Lion Energy Registry: CEC Verified Engineering Specification

Lion Energy: #50170168 {240V} outputs 8,084 W AC at 240 V (33.7 A continuous, 45 A OCPD), ranking #896 of 2,343 CEC inverters at 97.09% efficiency with a 250-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
8,084 W
AC Voltage
240 V
Min PV Breaker
45 A (8 AWG Cu)
CEC Efficiency
97.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lion Energy: #50170168 {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#896), 250-430 V MPPT tracking, and panel fit for Lion Energy: #50170168 {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Operating at 240 V, Lion Energy: #50170168 {240V} converts DC array energy at 97.09% CEC weighted efficiency (top 38.6%; higher than 61.4% of peers) with a 430 V max DC input and 23.1297 A max input current for NEC 690.7 string safety. Compare this 8,084 W hybrid battery-capable inverter directly with Amensolar Ess Co Ltd: N3H-X80-US {240V} (8,084 W). Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

Where Does Lion Energy: #50170168 {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Lion Energy: #50170168 {240V} at 8,084 W continuous AC output. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Lion Energy: #50170168 {240V} (8,084 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACLion Energy: #5017: 8,084 W

What Dataset Percentiles Define Lion Energy: #50170168 {240V}?

Dataset percentiles comparing Lion Energy: #50170168 {240V} against 2,343 certified grid-support inverters nationwide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Lion Energy: #50170168 {240V} Technical ThresholdsPercentile comparison for Lion Energy: #50170168 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output8,084 WCEC Efficiency97.09%Backfeed Breaker45 A

What Do the Dataset Ranks Show for Lion Energy: #50170168 {240V}?

Engineering highlights for Lion Energy: #50170168 {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Eff #896 / 2,343

97.09% CEC Weighted Efficiency

+0.41 pts vs the 96.68% 240 V median; overall power rank #1,099 (8,084 W, top 47.2%; higher than 52.8% of peers).

NEC 705.12 Check

45 A Required Backfeed OCPD

125% x 33.7 A = 42.1 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

250 V - 430 V (Max 430 V DC)

Tracking span of 180.0 V; listed since 2024-05-21 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8084.0W / 240 V -> 33.7 A | Breaker >= 1.25 * 33.7 = 42.1 A -> 45 A

CEC Inverters.csv for Lion Energy: #50170168 {240V}: Paco=8084.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=97.09%.

Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Lion Energy: #50170168 {240V}?

California Energy Commission Solar Equipment List parameters for Lion Energy: #50170168 {240V} (hybrid battery-capable inverter) interconnection. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Lion Energy: #50170168 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 8,084 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 430 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 250 V - 430 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 23.1297 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.09% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-05-21 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Lion Energy: #50170168 {240V}?

Panelboard and switchgear backfeed allowances for Lion Energy: #50170168 {240V} (45 A OCPD). Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates Lion Energy: #50170168 {240V} (45 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 45 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 45 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 45 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 45 A PASS (120% Rule)
225A Bus / 200A Main 70 A 45 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Lion Energy: #50170168 {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Lion Energy: #50170168 {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sampled CEC PV modules aligned within 250.0-430.0 V MPPT and 430.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 9 panels 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 10 panels 2.0 kW

Which Competing Grid-Support Inverters Compare to Lion Energy: #50170168 {240V}?

Four alternative CEC inverters matched to Lion Energy: #50170168 {240V} (8,084 W AC), led by Amensolar Ess Co Ltd: N3H-X80-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X80-US {240V}
Amensolar Ess Co Ltd
8,084 W Tie (0 W) 240.0 V 430.0 V 97.08%
Amensolar Ess Co Ltd: N3H-X8US {240V}
Amensolar Ess Co Ltd
8,084 W Tie (0 W) 240.0 V 430.0 V 97.08%
Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
7,999 W -85 W 240.0 V 480.0 V 97.79%
Base Power Inc: MIN 8200TL-XH-US {240V}
Base Power Inc
8,251 W +167 W 240.0 V 480.0 V 97.7%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Lion Energy: #50170168 {240V}?

Check Lion Energy: #50170168 {240V} (8,084 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on Lion Energy: #50170168 {240V}.

Lion Energy: #50170168 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (33.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.09%) and MPPT window (250-430 V) directly against Amensolar Ess Co Ltd: N3H-X80-US {240V} (8,084 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Lion Energy: #50170168 {240V} by Lion Energy covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Lion Energy: #50170168 {240V} require?

At 8,084 W continuous AC (240 V), continuous current is 33.7 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

Does Lion Energy: #50170168 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

How does Lion Energy: #50170168 {240V} compare to Amensolar Ess Co Ltd: N3H-X80-US {240V}?

Lion Energy: #50170168 {240V} delivers 8,084 W AC at 97.09% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X80-US {240V} outputs 8,084 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.