Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} — CEC Inverter Specifications

Manufacturer: Kowint Energy (Shenzhen) Co Ltd Registry: CEC Verified Engineering Specification

Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} outputs 125,015 W AC at 480 V, 3-phase (150.4 A continuous, 200 A OCPD), ranking #136 of 2,343 CEC inverters at 98.37% efficiency with a 720.0-1,300.1 V MPPT window and 1,300.1 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
125,015 W
AC Voltage
480 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
98.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} Compare Against Peer CEC Listings?

Breaker sizing (200 A), 3/0 AWG Cu wire rules, and DC input limits for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}.

Classified as a grid-tied PV inverter (active in CEC directory), Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} requires 188.0 A design capacity -> 200 A breaker using 3/0 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 98.37% (+1.55 pts vs overall CEC median) across 2,343 CEC models, while commercial 480 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (480v) or nec 705.11 supply-side tap.

Where Does Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} Fall Across Listed CEC Models?

Output power comparison showing where Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} (125,015 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACKowint Energy (She: 125,015 W

What Dataset Percentiles Define Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}?

Relative ranking of Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} Technical ThresholdsPercentile comparison for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output125,015 WCEC Efficiency98.37%Backfeed Breaker200 A

What Do the Dataset Ranks Show for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}?

Snapshot of Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} efficiency rank (#136), OCPD breaker size, MPPT span, and busbar verdict.

Eff #136 / 2,343

98.37% CEC Weighted Efficiency

+0.35 pts vs the 98.02% 480 V median; overall power rank #297 (125,015 W, top 12.7%; higher than 87.3% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 150.4 A = 188.0 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

720.0 V - 1,300.1 V (Max 1,300.1 V DC)

Tracking span of 580.1 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 125015.0W / 480 V 3-phase -> 150.4 A | Breaker >= 1.25 * 150.4 = 188.0 A -> 200 A

CEC Inverters.csv for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}: Paco=125015.0 W, Vac=480 V, Vdcmax=1300.1 V, Eff=98.37%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 125,015 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,300.1 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 720.0 V - 1,300.1 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 125.819 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.37% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} at 480 V, 3-phase.

Evaluates Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} (200 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (480V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}?

Minimum and maximum series solar module strings fitting Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} MPPT and 1,300.1 V limits.

Sampled CEC PV modules aligned within 720.015-1300.1 V MPPT and 1300.1 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 17 to 23 panels 13.57 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 22 to 30 panels 13.2 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 21 to 29 panels 12.32 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 25 to 32 panels 6.4 kW

Which Competing Grid-Support Inverters Compare to Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}?

Peer 480 V, 3-phase CEC inverters near 125,015 W AC output such as Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}
Chint Power Systems America
125,000 W -15 W 480.0 V 1100.0 V 97.2%
Delta Electronics: DES10JB125K01 {480V}
Delta Electronics
125,000 W -15 W 480.0 V 1000.0 V 97.01%
Delta Electronics: PCS125 {480V}
Delta Electronics
125,000 W -15 W 480.0 V 1000.0 V 97.01%
Ginlong Technologies Co Ltd: S5-GC125K-US {480V}
Ginlong Technologies Co Ltd
124,991 W -24 W 480.0 V 850.0 V 97.88%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}?

Check Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} (125,015 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300.1 V DC on Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V}.

Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (150.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.37%) and MPPT window (720.0-1,300.1 V) directly against Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V} (125,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} by Kowint Energy (Shenzhen) Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} require?

At 125,015 W continuous AC (480 V, 3-phase), continuous current is 150.4 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} require?

At 125,015 W AC and 480 V, 3-phase, continuous line current is 150.4 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} compare to Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V}?

Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V} delivers 125,015 W AC at 98.37% CEC efficiency with a 1,300.1 V DC ceiling, while Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V} outputs 125,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.