INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} — CEC Inverter Specifications

Manufacturer: INGETEAM POWER TECHNOLOGY SA Registry: CEC Verified Engineering Specification

INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} outputs 3,240,000 W AC at 760 V, 3-phase (2461.4 A continuous, 3,100 A OCPD), ranking #229 of 2,343 CEC inverters at 98.24% efficiency with a 1,180-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,240,000 W
AC Voltage
760 V, 3-phase
Min PV Breaker
3,100 A (parallel Cu feeders)
CEC Efficiency
98.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} Compare Against Peer CEC Listings?

How INGETEAM POWER TECHNOLOGY SA INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} compares on 98.24% efficiency, MPPT span, and 120% busbar interconnection.

INGETEAM POWER TECHNOLOGY SA certifies INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (grid-tied PV inverter, active in CEC directory) at 3,240,000 W AC (equal to the 3,240,000 W 760 V median). Its 1,500 V DC ceiling pairs with an MPPT window of 1,180-1,500 V (span 320.0 V). Under NEC 690.8/705.12, 125% sizing demands parallel Cu feeders conductors on a 3,100 A OCPD.

Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} Fall Across Listed CEC Models?

Position of INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (3,240,000 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (3,240,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACINGETEAM POWER TEC: 3,240,000 W

What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}?

Percentile placement of INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} across AC power class, conversion efficiency, and backfeed breaker size.

INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} Technical ThresholdsPercentile comparison for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,240,000 WCEC Efficiency98.24%Backfeed Breaker3,100 A

What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}.

Eff #229 / 2,343

98.24% CEC Weighted Efficiency

equal to the 98.24% 760 V median; overall power rank #39 (3,240,000 W, top 1.7%; higher than 98.3% of peers).

NEC 705.12 Check

3,100 A Required Backfeed OCPD

125% x 2461.4 A = 3076.8 A -> 3,100 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,180 V - 1,500 V (Max 1,500 V DC)

Tracking span of 320.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 760 V, 3-phase switchgear (200A Bus / 200A Main (760V) to 1,200A Bus / 1,200A Main (760V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3240000.0W / 760 V 3-phase -> 2461.4 A | Breaker >= 1.25 * 2461.4 = 3076.8 A -> 3,100 A

CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}: Paco=3240000.0 W, Vac=760 V, Vdcmax=1500.0 V, Eff=98.24%.

Result: Min 3,100 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (760V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}.

Official California Energy Commission (NREL SAM) test parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,240,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 760 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,180 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 2442.88 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.24% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (760 V, 3-phase)?

Check whether INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (3,100 A breaker) fits without main breaker derate or supply-side taps.

Evaluates INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (3100 A required OCPD at 760 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (760V) 40 A 3,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (760V) 80 A 3,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (760V) 120 A 3,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (760V) 160 A 3,100 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (760V) 240 A 3,100 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}?

Alternative CEC inverters comparable to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}, including Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W) at 760 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Sungrow Power Supply Co Ltd: SG3150U {630V}
Sungrow Power Supply Co Ltd
3,154,300 W -85700 W 630.0 V 1300.0 V 97.49%
Power Electronics: FS2250CU15O3 {600V}
Power Electronics
2,420,370 W -819630 W 600.0 V 1200.0 V 97.82%
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -1513300 W 690.0 V 1500.0 V 98.32%
Schneider Electric USA Inc: CS1666-3-NA {575V}
Schneider Electric USA Inc
1,666,000 W -1574000 W 575.0 V 1200.0 V 97.54%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}?

Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} (3,240,000 W AC, 3,100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 760 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (760V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V}.

INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,100 A OCPD breaker (2461.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.24%) and MPPT window (1,180-1,500 V) directly against Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 760 V, 3-phase interconnection.

What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} require?

At 3,240,000 W continuous AC (760 V, 3-phase), continuous current is 2461.4 A; 125% NEC 690.8/705.12 sizing requires a 3,100 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} require?

At 3,240,000 W AC and 760 V, 3-phase, continuous line current is 2461.4 A, requiring a 3,100 A OCPD and 1,200A Bus / 1,200A Main (760V) or NEC 705.11 interconnection.

How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} compare to Sungrow Power Supply Co Ltd: SG3150U {630V}?

INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V} delivers 3,240,000 W AC at 98.24% CEC efficiency with a 1,500 V DC ceiling, while Sungrow Power Supply Co Ltd: SG3150U {630V} outputs 3,154,300 W at 760 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.