INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} outputs 3,304,620 W AC at 645 V, 3-phase (2958.1 A continuous, 3,700 A OCPD), ranking #459 of 2,343 CEC inverters at 97.72% efficiency with a 919-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,304,620 W
- AC Voltage
- 645 V, 3-phase
- Min PV Breaker
- 3,700 A (parallel Cu feeders)
- CEC Efficiency
- 97.72%
How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} Compare Against Peer CEC Listings?
CEC efficiency rank (#459), 919-1,300 V MPPT tracking, and panel fit for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}.
Operating at 645 V, 3-phase, INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} converts DC array energy at 97.72% CEC weighted efficiency (top 20.0%; higher than 80.0% of peers) with a 1,300 V max DC input and 2822.74 A max input current for NEC 690.7 string safety. Compare this 3,304,620 W grid-tied PV inverter directly with Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W). Commercial 645 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (645V) or NEC 705.11 supply-side tap.
Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} at 3,304,620 W continuous AC output.
What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}?
Dataset percentiles comparing INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} against 2,343 certified grid-support inverters nationwide.
What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}?
Engineering highlights for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.
97.72% CEC Weighted Efficiency
-0.03 pts vs the 97.75% 645 V median; overall power rank #35 (3,304,620 W, top 1.5%; higher than 98.5% of peers).
3,700 A Required Backfeed OCPD
125% x 2958.1 A = 3697.6 A -> 3,700 A standard OCPD using parallel Cu feeders (75 C).
919 V - 1,300 V (Max 1,300 V DC)
Tracking span of 381.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 645 V, 3-phase switchgear (200A Bus / 200A Main (645V) to 1,200A Bus / 1,200A Main (645V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3304620.0W / 645 V 3-phase -> 2958.1 A | Breaker >= 1.25 * 2958.1 = 3697.6 A -> 3,700 A
CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}: Paco=3304620.0 W, Vac=645 V, Vdcmax=1300.0 V, Eff=97.72%.
Result: Min 3,700 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (645V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}?
California Energy Commission Solar Equipment List parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,304,620 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 645 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,300 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 919 V - 1,300 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 2822.74 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.72% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} (645 V, 3-phase)?
Panelboard and switchgear backfeed allowances for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} (3,700 A OCPD).
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (645V) | 40 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (645V) | 80 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (645V) | 120 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (645V) | 160 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (645V) | 240 A | 3,700 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 22 to 23 panels | 13.57 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 28 to 30 panels | 13.2 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 27 to 29 panels | 12.32 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 32 panels (fixed) | 6.4 kW |
Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}?
Four alternative CEC inverters matched to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} (3,304,620 W AC), led by Sungrow Power Supply Co Ltd: SG3150U {630V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Sungrow Power Supply Co Ltd: SG3150U {630V} Sungrow Power Supply Co Ltd |
3,154,300 W | -150320 W | 630.0 V | 1300.0 V | 97.49% |
| Power Electronics: FS2250CU15O3 {600V} Power Electronics |
2,420,370 W | -884250 W | 600.0 V | 1200.0 V | 97.82% |
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | -1577920 W | 690.0 V | 1500.0 V | 98.32% |
| Schneider Electric USA Inc: CS1666-3-NA {575V} Schneider Electric USA Inc |
1,666,000 W | -1638620 W | 575.0 V | 1200.0 V | 97.54% |
What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}?
Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} (3,304,620 W AC, 3,700 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 645 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (645V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V}.
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 3,700 A OCPD breaker (2958.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.72%) and MPPT window (919-1,300 V) directly against Sungrow Power Supply Co Ltd: SG3150U {630V} (3,154,300 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 645 V, 3-phase interconnection.
What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} require?
At 3,304,620 W continuous AC (645 V, 3-phase), continuous current is 2958.1 A; 125% NEC 690.8/705.12 sizing requires a 3,700 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} require?
At 3,304,620 W AC and 645 V, 3-phase, continuous line current is 2958.1 A, requiring a 3,700 A OCPD and 1,200A Bus / 1,200A Main (645V) or NEC 705.11 interconnection.
How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} compare to Sungrow Power Supply Co Ltd: SG3150U {630V}?
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V} delivers 3,304,620 W AC at 97.72% CEC efficiency with a 1,300 V DC ceiling, while Sungrow Power Supply Co Ltd: SG3150U {630V} outputs 3,154,300 W at 645 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)