Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Holu Hou Energy LLC: HH9600H-HI {240V} — CEC Inverter Specifications

Manufacturer: Holu Hou Energy LLC Registry: CEC Verified Engineering Specification

Holu Hou Energy LLC: HH9600H-HI {240V} outputs 9,628 W AC at 240 V (40.1 A continuous, 60 A OCPD), ranking #1,249 of 2,343 CEC inverters at 96.73% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,628 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.73%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Holu Hou Energy LLC: HH9600H-HI {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,249), 300-480 V MPPT tracking, and panel fit for Holu Hou Energy LLC: HH9600H-HI {240V}.

Operating at 240 V, Holu Hou Energy LLC: HH9600H-HI {240V} converts DC array energy at 96.73% CEC weighted efficiency (below overall CEC median; higher than 46.2% of peers) with a 480 V max DC input and 24.8847 A max input current for NEC 690.7 string safety. Compare this 9,628 W hybrid battery-capable inverter directly with Alpha ESS Co Ltd: SMILE-SP96-INV {240V} (9,628 W). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

Where Does Holu Hou Energy LLC: HH9600H-HI {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Holu Hou Energy LLC: HH9600H-HI {240V} at 9,628 W continuous AC output. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Holu Hou Energy LLC: HH9600H-HI {240V} (9,628 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACHolu Hou Energy LL: 9,628 W

What Dataset Percentiles Define Holu Hou Energy LLC: HH9600H-HI {240V}?

Dataset percentiles comparing Holu Hou Energy LLC: HH9600H-HI {240V} against 2,343 certified grid-support inverters nationwide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Holu Hou Energy LLC: HH9600H-HI {240V} Technical ThresholdsPercentile comparison for Holu Hou Energy LLC: HH9600H-HI {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,628 WCEC Efficiency96.73%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Holu Hou Energy LLC: HH9600H-HI {240V}?

Engineering highlights for Holu Hou Energy LLC: HH9600H-HI {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.

Eff #1,249 / 2,343

96.73% CEC Weighted Efficiency

+0.05 pts vs the 96.68% 240 V median; overall power rank #963 (9,628 W, top 41.4%; higher than 58.6% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 40.1 A = 50.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

300 V - 480 V (Max 480 V DC)

Tracking span of 180.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9628.0W / 240 V -> 40.1 A | Breaker >= 1.25 * 40.1 = 50.1 A -> 60 A

CEC Inverters.csv for Holu Hou Energy LLC: HH9600H-HI {240V}: Paco=9628.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.73%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Holu Hou Energy LLC: HH9600H-HI {240V}?

California Energy Commission Solar Equipment List parameters for Holu Hou Energy LLC: HH9600H-HI {240V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Holu Hou Energy LLC: HH9600H-HI {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,628 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 300 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 24.8847 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.73% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Holu Hou Energy LLC: HH9600H-HI {240V}?

Panelboard and switchgear backfeed allowances for Holu Hou Energy LLC: HH9600H-HI {240V} (60 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Holu Hou Energy LLC: HH9600H-HI {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Holu Hou Energy LLC: HH9600H-HI {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Holu Hou Energy LLC: HH9600H-HI {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 300.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 9 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 11 panels (fixed) 2.2 kW

Which Competing Grid-Support Inverters Compare to Holu Hou Energy LLC: HH9600H-HI {240V}?

Four alternative CEC inverters matched to Holu Hou Energy LLC: HH9600H-HI {240V} (9,628 W AC), led by Alpha ESS Co Ltd: SMILE-SP96-INV {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Alpha ESS Co Ltd: SMILE-SP96-INV {240V}
Alpha ESS Co Ltd
9,628 W Tie (0 W) 240.0 V 480.0 V 96.73%
Delta Electronics: E10-TL-US(AC) {240V}
Delta Electronics
9,632 W +4 W 240.0 V 480.0 V 97.79%
Delta Electronics: M10-TL-US {240V}
Delta Electronics
9,620 W -8 W 240.0 V 480.0 V 97.07%
Alpha ESS Co Ltd: SMILE-SPB96-INV {240V}
Alpha ESS Co Ltd
9,616 W -12 W 240.0 V 450.0 V 96.15%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Holu Hou Energy LLC: HH9600H-HI {240V}?

Check Holu Hou Energy LLC: HH9600H-HI {240V} (9,628 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Holu Hou Energy LLC: HH9600H-HI {240V}.

Holu Hou Energy LLC: HH9600H-HI {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.73%) and MPPT window (300-480 V) directly against Alpha ESS Co Ltd: SMILE-SP96-INV {240V} (9,628 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Holu Hou Energy LLC: HH9600H-HI {240V} by Holu Hou Energy LLC covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Holu Hou Energy LLC: HH9600H-HI {240V} require?

At 9,628 W continuous AC (240 V), continuous current is 40.1 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Holu Hou Energy LLC: HH9600H-HI {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Holu Hou Energy LLC: HH9600H-HI {240V} compare to Alpha ESS Co Ltd: SMILE-SP96-INV {240V}?

Holu Hou Energy LLC: HH9600H-HI {240V} delivers 9,628 W AC at 96.73% CEC efficiency with a 480 V DC ceiling, while Alpha ESS Co Ltd: SMILE-SP96-INV {240V} outputs 9,628 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.