GoodWe Technologies Co Ltd: GW9600A-MS {240V} outputs 9,628 W AC at 240 V (40.1 A continuous, 60 A OCPD), ranking #1,249 of 2,343 CEC inverters at 96.73% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,628 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.73%
How Does GoodWe Technologies Co Ltd: GW9600A-MS {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,249), 300-480 V MPPT tracking, and panel fit for GoodWe Technologies Co Ltd: GW9600A-MS {240V}.
GoodWe Technologies Co Ltd: GW9600A-MS {240V} from GoodWe Technologies Co Ltd outputs 40.1 A continuous AC at 240 V (9,628 W AC, rank #963). Paired with 6 AWG Cu conductors and a 60 A OCPD, its 96.73% CEC efficiency compares closely with Alpha ESS Co Ltd: SMILE-SP96-INV {240V} (9,628 W). Keep NEC 690.7 winter string Voc below 480 V DC.
Where Does GoodWe Technologies Co Ltd: GW9600A-MS {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting GoodWe Technologies Co Ltd: GW9600A-MS {240V} at 9,628 W continuous AC output. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
Dataset percentiles comparing GoodWe Technologies Co Ltd: GW9600A-MS {240V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
Engineering highlights for GoodWe Technologies Co Ltd: GW9600A-MS {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.
96.73% CEC Weighted Efficiency
+0.05 pts vs the 96.68% 240 V median; overall power rank #963 (9,628 W, top 41.4%; higher than 58.6% of peers).
60 A Required Backfeed OCPD
125% x 40.1 A = 50.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
300 V - 480 V (Max 480 V DC)
Tracking span of 180.0 V; listed since 2023-02-13 (grid-tied PV inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9628.0W / 240 V -> 40.1 A | Breaker >= 1.25 * 40.1 = 50.1 A -> 60 A
CEC Inverters.csv for GoodWe Technologies Co Ltd: GW9600A-MS {240V}: Paco=9628.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.73%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
California Energy Commission Solar Equipment List parameters for GoodWe Technologies Co Ltd: GW9600A-MS {240V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,628 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 24.8847 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.73% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-02-13 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
Panelboard and switchgear backfeed allowances for GoodWe Technologies Co Ltd: GW9600A-MS {240V} (60 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for GoodWe Technologies Co Ltd: GW9600A-MS {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |
Which Competing Grid-Support Inverters Compare to GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
Four alternative CEC inverters matched to GoodWe Technologies Co Ltd: GW9600A-MS {240V} (9,628 W AC), led by Alpha ESS Co Ltd: SMILE-SP96-INV {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Alpha ESS Co Ltd: SMILE-SP96-INV {240V} Alpha ESS Co Ltd |
9,628 W | Tie (0 W) | 240.0 V | 480.0 V | 96.73% |
| Delta Electronics: E10-TL-US(AC) {240V} Delta Electronics |
9,632 W | +4 W | 240.0 V | 480.0 V | 97.79% |
| Delta Electronics: M10-TL-US {240V} Delta Electronics |
9,620 W | -8 W | 240.0 V | 480.0 V | 97.07% |
| Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} Alpha ESS Co Ltd |
9,616 W | -12 W | 240.0 V | 450.0 V | 96.15% |
What Are the Interconnection Limits and Best-Fit Uses for GoodWe Technologies Co Ltd: GW9600A-MS {240V}?
Check GoodWe Technologies Co Ltd: GW9600A-MS {240V} (9,628 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on GoodWe Technologies Co Ltd: GW9600A-MS {240V}.
GoodWe Technologies Co Ltd: GW9600A-MS {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.73%) and MPPT window (300-480 V) directly against Alpha ESS Co Ltd: SMILE-SP96-INV {240V} (9,628 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for GoodWe Technologies Co Ltd: GW9600A-MS {240V} by GoodWe Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does GoodWe Technologies Co Ltd: GW9600A-MS {240V} require?
At 9,628 W continuous AC (240 V), continuous current is 40.1 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does GoodWe Technologies Co Ltd: GW9600A-MS {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does GoodWe Technologies Co Ltd: GW9600A-MS {240V} compare to Alpha ESS Co Ltd: SMILE-SP96-INV {240V}?
GoodWe Technologies Co Ltd: GW9600A-MS {240V} delivers 9,628 W AC at 96.73% CEC efficiency with a 480 V DC ceiling, while Alpha ESS Co Ltd: SMILE-SP96-INV {240V} outputs 9,628 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)