GoodWe Technologies Co Ltd: GW9600A-ES {240V} outputs 9,628 W AC at 240 V (40.1 A continuous, 60 A OCPD), ranking #1,249 of 2,343 CEC inverters at 96.73% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,628 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.73%
How Does GoodWe Technologies Co Ltd: GW9600A-ES {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,249), 300-480 V MPPT tracking, and panel fit for GoodWe Technologies Co Ltd: GW9600A-ES {240V}.
GoodWe Technologies Co Ltd: GW9600A-ES {240V} from GoodWe Technologies Co Ltd outputs 40.1 A continuous AC at 240 V (9,628 W AC, rank #963). Paired with 6 AWG Cu conductors and a 60 A OCPD, its 96.73% CEC efficiency compares closely with Alpha ESS Co Ltd: SMILE-SP96-INV {240V} (9,628 W). Keep NEC 690.7 winter string Voc below 480 V DC.
Where Does GoodWe Technologies Co Ltd: GW9600A-ES {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting GoodWe Technologies Co Ltd: GW9600A-ES {240V} at 9,628 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
Dataset percentiles comparing GoodWe Technologies Co Ltd: GW9600A-ES {240V} against 2,343 certified grid-support inverters nationwide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
Engineering highlights for GoodWe Technologies Co Ltd: GW9600A-ES {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.
96.73% CEC Weighted Efficiency
+0.05 pts vs the 96.68% 240 V median; overall power rank #963 (9,628 W, top 41.4%; higher than 58.6% of peers).
60 A Required Backfeed OCPD
125% x 40.1 A = 50.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
300 V - 480 V (Max 480 V DC)
Tracking span of 180.0 V; listed since 2023-02-13 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9628.0W / 240 V -> 40.1 A | Breaker >= 1.25 * 40.1 = 50.1 A -> 60 A
CEC Inverters.csv for GoodWe Technologies Co Ltd: GW9600A-ES {240V}: Paco=9628.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.73%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
California Energy Commission Solar Equipment List parameters for GoodWe Technologies Co Ltd: GW9600A-ES {240V} (hybrid battery-capable inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,628 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 24.8847 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.73% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-02-13 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
Panelboard and switchgear backfeed allowances for GoodWe Technologies Co Ltd: GW9600A-ES {240V} (60 A OCPD). Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for GoodWe Technologies Co Ltd: GW9600A-ES {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 11 panels (fixed) | 2.2 kW |
Which Competing Grid-Support Inverters Compare to GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
Four alternative CEC inverters matched to GoodWe Technologies Co Ltd: GW9600A-ES {240V} (9,628 W AC), led by Alpha ESS Co Ltd: SMILE-SP96-INV {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Alpha ESS Co Ltd: SMILE-SP96-INV {240V} Alpha ESS Co Ltd |
9,628 W | Tie (0 W) | 240.0 V | 480.0 V | 96.73% |
| Delta Electronics: E10-TL-US(AC) {240V} Delta Electronics |
9,632 W | +4 W | 240.0 V | 480.0 V | 97.79% |
| Delta Electronics: M10-TL-US {240V} Delta Electronics |
9,620 W | -8 W | 240.0 V | 480.0 V | 97.07% |
| Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} Alpha ESS Co Ltd |
9,616 W | -12 W | 240.0 V | 450.0 V | 96.15% |
What Are the Interconnection Limits and Best-Fit Uses for GoodWe Technologies Co Ltd: GW9600A-ES {240V}?
Check GoodWe Technologies Co Ltd: GW9600A-ES {240V} (9,628 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on GoodWe Technologies Co Ltd: GW9600A-ES {240V}.
GoodWe Technologies Co Ltd: GW9600A-ES {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.73%) and MPPT window (300-480 V) directly against Alpha ESS Co Ltd: SMILE-SP96-INV {240V} (9,628 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for GoodWe Technologies Co Ltd: GW9600A-ES {240V} by GoodWe Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does GoodWe Technologies Co Ltd: GW9600A-ES {240V} require?
At 9,628 W continuous AC (240 V), continuous current is 40.1 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does GoodWe Technologies Co Ltd: GW9600A-ES {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does GoodWe Technologies Co Ltd: GW9600A-ES {240V} compare to Alpha ESS Co Ltd: SMILE-SP96-INV {240V}?
GoodWe Technologies Co Ltd: GW9600A-ES {240V} delivers 9,628 W AC at 96.73% CEC efficiency with a 480 V DC ceiling, while Alpha ESS Co Ltd: SMILE-SP96-INV {240V} outputs 9,628 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)