GoodWe Technologies Co Ltd: GW9600A-BP {240V} outputs 9,616 W AC at 240 V (40.1 A continuous, 60 A OCPD), ranking #1,916 of 2,343 CEC inverters at 96.08% efficiency with a 200-495 V MPPT window and 495 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,616 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.08%
How Does GoodWe Technologies Co Ltd: GW9600A-BP {240V} Compare Against Peer CEC Listings?
How GoodWe Technologies Co Ltd GoodWe Technologies Co Ltd: GW9600A-BP {240V} compares on 96.08% efficiency, MPPT span, and 120% busbar interconnection.
GoodWe Technologies Co Ltd certifies GoodWe Technologies Co Ltd: GW9600A-BP {240V} (grid-tied PV inverter, listed since 2023-12-11) at 9,616 W AC (3,840 W above the 5,776 W 240 V median). Its 495 V DC ceiling pairs with an MPPT window of 200-495 V (span 295.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.
Where Does GoodWe Technologies Co Ltd: GW9600A-BP {240V} Fall Across Listed CEC Models?
Position of GoodWe Technologies Co Ltd: GW9600A-BP {240V} (9,616 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Percentile placement of GoodWe Technologies Co Ltd: GW9600A-BP {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for GoodWe Technologies Co Ltd: GW9600A-BP {240V}.
96.08% CEC Weighted Efficiency
-0.60 pts vs the 96.68% 240 V median; overall power rank #971 (9,616 W, top 41.5%; higher than 58.5% of peers).
60 A Required Backfeed OCPD
125% x 40.1 A = 50.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
200 V - 495 V (Max 495 V DC)
Tracking span of 295.0 V; listed since 2023-12-11 (grid-tied PV inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9616.0W / 240 V -> 40.1 A | Breaker >= 1.25 * 40.1 = 50.1 A -> 60 A
CEC Inverters.csv for GoodWe Technologies Co Ltd: GW9600A-BP {240V}: Paco=9616.0 W, Vac=240 V, Vdcmax=495.0 V, Eff=96.08%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for GoodWe Technologies Co Ltd: GW9600A-BP {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,616 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 495 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 495 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 28.5943 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.08% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-12-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Check whether GoodWe Technologies Co Ltd: GW9600A-BP {240V} (60 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Verified cold-weather (-10 C) series module counts matched to GoodWe Technologies Co Ltd: GW9600A-BP {240V}'s 495 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 12 panels | 2.4 kW |
Which Competing Grid-Support Inverters Compare to GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Alternative CEC inverters comparable to GoodWe Technologies Co Ltd: GW9600A-BP {240V}, including Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} (9,616 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} Alpha ESS Co Ltd |
9,616 W | Tie (0 W) | 240.0 V | 450.0 V | 96.15% |
| Delta Electronics: M10-TL-US {240V} Delta Electronics |
9,620 W | +4 W | 240.0 V | 480.0 V | 97.07% |
| Altenergy Power System Inc: ELS-96 {240V} Altenergy Power System Inc |
9,606 W | -10 W | 240.0 V | 60.0 V | 93.76% |
| Alpha ESS Co Ltd: SMILE-SP96-INV {240V} Alpha ESS Co Ltd |
9,628 W | +12 W | 240.0 V | 480.0 V | 96.73% |
What Are the Interconnection Limits and Best-Fit Uses for GoodWe Technologies Co Ltd: GW9600A-BP {240V}?
Check GoodWe Technologies Co Ltd: GW9600A-BP {240V} (9,616 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 495 V DC on GoodWe Technologies Co Ltd: GW9600A-BP {240V}.
GoodWe Technologies Co Ltd: GW9600A-BP {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (40.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.08%) and MPPT window (200-495 V) directly against Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} (9,616 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for GoodWe Technologies Co Ltd: GW9600A-BP {240V} by GoodWe Technologies Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does GoodWe Technologies Co Ltd: GW9600A-BP {240V} require?
At 9,616 W continuous AC (240 V), continuous current is 40.1 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does GoodWe Technologies Co Ltd: GW9600A-BP {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does GoodWe Technologies Co Ltd: GW9600A-BP {240V} compare to Alpha ESS Co Ltd: SMILE-SPB96-INV {240V}?
GoodWe Technologies Co Ltd: GW9600A-BP {240V} delivers 9,616 W AC at 96.08% CEC efficiency with a 495 V DC ceiling, while Alpha ESS Co Ltd: SMILE-SPB96-INV {240V} outputs 9,616 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)