Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Fronius International GmbH: Primo GEN24 77 208-240 {240V} — CEC Inverter Specifications

Manufacturer: Fronius International GmbH Registry: CEC Verified Engineering Specification

Fronius International GmbH: Primo GEN24 77 208-240 {240V} outputs 7,686 W AC at 240 V (32.0 A continuous, 40 A OCPD), ranking #906 of 2,343 CEC inverters at 97.08% efficiency with a 260-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,686 W
AC Voltage
240 V
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
97.08%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fronius International GmbH: Primo GEN24 77 208-240 {240V} Compare Against Peer CEC Listings?

How Fronius International GmbH Fronius International GmbH: Primo GEN24 77 208-240 {240V} compares on 97.08% efficiency, MPPT span, and 120% busbar interconnection.

With a 260-480 V MPPT tracking band and 480 V DC ceiling, Fronius International GmbH: Primo GEN24 77 208-240 {240V} handles 7,686 W continuous AC (1,910 W above the 5,776 W 240 V median). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing Fronius International GmbH against Anker Innovations Limited: A17E1 {240V} (7,687 W) should verify whether listed since 2025-05-01 grid-support firmware meets local IEEE 1547 utility rules.

Where Does Fronius International GmbH: Primo GEN24 77 208-240 {240V} Fall Across Listed CEC Models?

Position of Fronius International GmbH: Primo GEN24 77 208-240 {240V} (7,686 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fronius International GmbH: Primo GEN24 77 208-240 {240V} (7,686 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFronius Internatio: 7,686 W

What Dataset Percentiles Define Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Percentile placement of Fronius International GmbH: Primo GEN24 77 208-240 {240V} across AC power class, conversion efficiency, and backfeed breaker size.

Fronius International GmbH: Primo GEN24 77 208-240 {240V} Technical ThresholdsPercentile comparison for Fronius International GmbH: Primo GEN24 77 208-240 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,686 WCEC Efficiency97.08%Backfeed Breaker40 A

What Do the Dataset Ranks Show for Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Fronius International GmbH: Primo GEN24 77 208-240 {240V}.

Eff #906 / 2,343

97.08% CEC Weighted Efficiency

+0.40 pts vs the 96.68% 240 V median; overall power rank #1,165 (7,686 W, top 49.8%; higher than 50.2% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 32.0 A = 40.0 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

260 V - 480 V (Max 480 V DC)

Tracking span of 220.0 V; listed since 2025-05-01 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7686.0W / 240 V -> 32.0 A | Breaker >= 1.25 * 32.0 = 40.0 A -> 40 A

CEC Inverters.csv for Fronius International GmbH: Primo GEN24 77 208-240 {240V}: Paco=7686.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.08%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Fronius International GmbH: Primo GEN24 77 208-240 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Primo GEN24 77 208-240 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,686 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 260 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 20.5634 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.08% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-05-01 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Check whether Fronius International GmbH: Primo GEN24 77 208-240 {240V} (40 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Fronius International GmbH: Primo GEN24 77 208-240 {240V} (40 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 40 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 40 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 40 A PASS (120% Rule)
200A Bus / 175A Main 65 A 40 A PASS (120% Rule)
225A Bus / 200A Main 70 A 40 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Verified cold-weather (-10 C) series module counts matched to Fronius International GmbH: Primo GEN24 77 208-240 {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 260.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Alternative CEC inverters comparable to Fronius International GmbH: Primo GEN24 77 208-240 {240V}, including Anker Innovations Limited: A17E1 {240V} (7,687 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Anker Innovations Limited: A17E1 {240V}
Anker Innovations Limited
7,687 W +1 W 240.0 V 450.0 V 95.96%
Delta Electronics: E8-TL-US {240V}
Delta Electronics
7,680 W -6 W 240.0 V 480.0 V 97.42%
Delta Electronics: M8-TL-US {240V}
Delta Electronics
7,680 W -6 W 240.0 V 480.0 V 97.42%
Delta Electronics: E8_BDI {240V}
Delta Electronics
7,716 W +30 W 240.0 V 480.0 V 97.27%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Primo GEN24 77 208-240 {240V}?

Check Fronius International GmbH: Primo GEN24 77 208-240 {240V} (7,686 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Primo GEN24 77 208-240 {240V}.

Fronius International GmbH: Primo GEN24 77 208-240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (32.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.08%) and MPPT window (260-480 V) directly against Anker Innovations Limited: A17E1 {240V} (7,687 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Primo GEN24 77 208-240 {240V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Fronius International GmbH: Primo GEN24 77 208-240 {240V} require?

At 7,686 W continuous AC (240 V), continuous current is 32.0 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

Does Fronius International GmbH: Primo GEN24 77 208-240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

How does Fronius International GmbH: Primo GEN24 77 208-240 {240V} compare to Anker Innovations Limited: A17E1 {240V}?

Fronius International GmbH: Primo GEN24 77 208-240 {240V} delivers 7,686 W AC at 97.08% CEC efficiency with a 480 V DC ceiling, while Anker Innovations Limited: A17E1 {240V} outputs 7,687 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.