Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} — CEC Inverter Specifications

Manufacturer: Fronius International GmbH Registry: CEC Verified Engineering Specification

Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} outputs 5,743 W AC at 208 V, commercial single-phase (27.6 A continuous, 35 A OCPD), ranking #1,203 of 2,343 CEC inverters at 96.8% efficiency with a 230-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,743 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
96.8%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} Compare Against Peer CEC Listings?

Breaker sizing (35 A), 8 AWG Cu wire rules, and DC input limits for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}.

For NEC 705.12 solar interconnection, Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} outputs 27.6 A continuous AC at 208 V, commercial single-phase and needs a 35 A backfeed breaker on 8 AWG Cu (75 C). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Conversion efficiency scores 96.8% (#1,203 of 2,343, -0.02 pts vs overall CEC median).

Where Does Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} Fall Across Listed CEC Models?

Output power comparison showing where Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} (5,743 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFronius Internatio: 5,743 W

What Dataset Percentiles Define Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}?

Relative ranking of Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} Technical ThresholdsPercentile comparison for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,743 WCEC Efficiency96.8%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}?

Snapshot of Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} efficiency rank (#1,203), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,203 / 2,343

96.8% CEC Weighted Efficiency

+0.39 pts vs the 96.41% 208 V median; overall power rank #1,442 (5,743 W, below CEC median; higher than 38.4% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 27.6 A = 34.5 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

230 V - 480 V (Max 480 V DC)

Tracking span of 250.0 V; listed since 2025-05-01 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5743.0W / 208 V -> 27.6 A | Breaker >= 1.25 * 27.6 = 34.5 A -> 35 A

CEC Inverters.csv for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}: Paco=5743.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.8%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,743 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 230 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 16.4807 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.8% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-05-01 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

What Switchgear Limits Apply to Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} at 208 V, commercial single-phase.

Evaluates Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} (35 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 35 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 35 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 35 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 35 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 35 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}?

Minimum and maximum series solar module strings fitting Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 230.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 8 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}?

Peer 208 V, commercial single-phase CEC inverters near 5,743 W AC output such as ABB: PVI-6000-OUTD-US-A {208V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-6000-OUTD-US-A {208V}
ABB
6,000 W +257 W 208.0 V 480.0 V 95.73%
ABB: PVI-6000-OUTD-US-Z-A {208V}
ABB
6,000 W +257 W 208.0 V 480.0 V 95.73%
ABB: PVI-6000-OUTD-US-Z-M-A {208V}
ABB
6,000 W +257 W 208.0 V 480.0 V 95.73%
ABB: UNO-DM-60-TL-PLUS-US-S-XRA {208V}
ABB
6,000 W +257 W 208.0 V 480.0 V 96.57%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}?

Check Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} (5,743 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V}.

Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (27.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.8%) and MPPT window (230-480 V) directly against ABB: PVI-6000-OUTD-US-A {208V} (6,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} require?

At 5,743 W continuous AC (208 V, commercial single-phase), continuous current is 27.6 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} require?

At 5,743 W AC and 208 V, commercial single-phase, continuous line current is 27.6 A, requiring a 35 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} compare to ABB: PVI-6000-OUTD-US-A {208V}?

Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V} delivers 5,743 W AC at 96.8% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-6000-OUTD-US-A {208V} outputs 6,000 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.