Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} — CEC Inverter Specifications

Manufacturer: Fronius International GmbH Registry: CEC Verified Engineering Specification

Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} outputs 12,000 W AC at 240 V (50.0 A continuous, 70 A OCPD), ranking #1,719 of 2,343 CEC inverters at 96.35% efficiency with a 300-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
12,000 W
AC Voltage
240 V
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
96.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} Compare Against Peer CEC Listings?

How Fronius International GmbH Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} compares on 96.35% efficiency, MPPT span, and 120% busbar interconnection.

Fronius International GmbH certifies Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} (grid-tied PV inverter, listed since 2019-03-01) at 12,000 W AC (6,224 W above the 5,776 W 240 V median). Its 480 V DC ceiling pairs with an MPPT window of 300-480 V (span 180.0 V). Under NEC 690.8/705.12, 125% sizing demands 4 AWG Cu conductors on a 70 A OCPD.

Where Does Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} Fall Across Listed CEC Models?

Position of Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} (12,000 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} (12,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFronius Internatio: 12,000 W

What Dataset Percentiles Define Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Percentile placement of Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} across AC power class, conversion efficiency, and backfeed breaker size.

Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} Technical ThresholdsPercentile comparison for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output12,000 WCEC Efficiency96.35%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}.

Eff #1,719 / 2,343

96.35% CEC Weighted Efficiency

-0.33 pts vs the 96.68% 240 V median; overall power rank #723 (12,000 W, top 31.1%; higher than 68.9% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 50.0 A = 62.5 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

300 V - 480 V (Max 480 V DC)

Tracking span of 180.0 V; listed since 2019-03-01 (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 12000.0W / 240 V -> 50.0 A | Breaker >= 1.25 * 50.0 = 62.5 A -> 70 A

CEC Inverters.csv for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}: Paco=12000.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.35%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 12,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 300 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 33.6628 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.35% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-03-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Check whether Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} (70 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} (70 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 70 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 70 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 70 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 70 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 70 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Verified cold-weather (-10 C) series module counts matched to Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 300.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 9 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 11 panels (fixed) 2.2 kW

Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Alternative CEC inverters comparable to Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}, including Chint Power Systems America: CPS ECH12KTL/US {240V} (11,990 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W -10 W 240.0 V 480.0 V 96.59%
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W +214 W 240.0 V 430.0 V 96.17%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -411 W 240.0 V 480.0 V 96.99%
Base Power Inc: MIN 11400TL-XH-US {240V}
Base Power Inc
11,520 W -480 W 240.0 V 480.0 V 97.76%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}?

Check Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} (12,000 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Fronius International GmbH: Fronius Symo 120-3 208-240 {240V}.

Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (50.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.35%) and MPPT window (300-480 V) directly against Chint Power Systems America: CPS ECH12KTL/US {240V} (11,990 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} require?

At 12,000 W continuous AC (240 V), continuous current is 50.0 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

Does Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.

How does Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} compare to Chint Power Systems America: CPS ECH12KTL/US {240V}?

Fronius International GmbH: Fronius Symo 120-3 208-240 {240V} delivers 12,000 W AC at 96.35% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS ECH12KTL/US {240V} outputs 11,990 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.